Power plant limitations Flashcards

1
Q

Allison _______ or ________

A

250-C20B or 250-C20J

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

N2 Power turbine operating RPM limits?

A

Min 97%

Max 100%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

N2 Transient overspeed limits?

A

100% torque-100-103%
0% torque-100-107%
Check Chart

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Gas producer N1 RPM limitations?

A

Max 105%

Transient 106% 15 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Torque limits?

A
  • Take off 100% 5 minutes
  • Transient 110% 5 second limit intentional use prohibited
  • Max Continueous 85%
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

TOT Limits?

A
  • Take off 810C
  • Max Continueous 738C
  • During power transient 810-843C 6 seconds intentional use prohibited
  • Starting and shut down 810-927C
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Exceeding limits _____ TOT or _____% torque may cause N1 topping and resultant rotor droop

A

793C TOT

100% torque

How well did you know this?
1
Not at all
2
3
4
5