Power and Distribution Flashcards
how may diesel generators are fitted to a generic distribution system
4 generators fitted to a ship
what does EDC stand for
Electrical Distribution Centre
How many EDC’s are fitted to a generic distribution system
4 EDC’s
What does MCCB stand for
Moulded case circuit Breaker
list 5 main breakers fitted to a generic distribution system
shore supply / ship along side breaker/ bus bar linking breaker/ feeder breaker/ interconnected breaker/ supply breaker
what is the power book and when is it used
power book shows distribution of all 440volts services used when tracing
what is the lighting book and when is it used
supply between 115-230volts and used the same as the power book
what is the ratio for 440v fuses regarding fuse discrimination
3:1
what is the ratio for 115v fuses regarding fuse discrimination
2:1
Explain breaker discrimination
is the stages of trips as you wouldn’t want a kettle to trip a main generator you would want a low trip to go 1st
What does MCR stand for
Machinery control room
What does PCP And SCP stand for
Primary control position
Secondary control position
list the meters fitted to a switchboard generator section
Voltmeter Ammeter KW meter Frequency meter syncroscope Earth fault indicator
Describe the shore connection supply
request shore supply 24hrs before
raise a permit to work
rack out shore supply breakers
obtain castle key from dockyard
continuity non contact and insulation resistance tests carried out on shore cables.
cables brought onboard and secured sufficient slack to allow tide rise
connect shore supply and ensure correct phase connection
inform dockyard ready for power.
what are the rules regarding to earthing the ship when connecting to shore supply
the ship must always be earthed to either the jetty or to the ship alongside by at least 2 points no less than half the ships length apart
what is used to confirm correct phase rotation with shore supply
right for bright lamp indicator
what would happen to a motor if phase rotation is wrong
motor would run backwards
list 3 types of hand change over switches
Normal / Alternative
Normal / Emergency
Normal / Alternative / Emergency
List 3 types of changer over switches
Hand changer over
Automatic Change over
Remote operated change over
What and where are the 440v earth testing facilities found
Earth indicator light / located on the switchboard some have audio alarms
Why are there separate 115v testing facilities
115v is a transformed supply and the secondary winding is not physically connected to the primary winding
What does C&C stand for
Control and Communication
define a converted supply
a converted supply has its voltage and or frequency changed from 450v 60hz