Positions/assignments Flashcards

1
Q

Old Law Tenement

1st due Irons

A

HT, Flashlight, Axe, Halligan, Hydra Ram

Door to fire Apt via interior stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Old Law Tenement

1st due can

A

HT, Flashlight, 6’ hook, Can

Door to fire Apartment via interior stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Old Law Tenement

1st due Chauffeur

A

HT, Flashlight, tools that the chauffeur deems necessary

Position: Front of the building. Chauffeur must notify their company officer if they leave their primary position.

(If 2nd did not in service or doesn’t show up in a reasonable time team with another member and go above the fire)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Old Law Tenement

First due OV (not top floor)

A

HT, Flashlight, Halligan, 6’ hook

Position: Assist chauffeur in front, then vent fire area from exterior

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Old Law Tenement

First due OV (store fire)

A

HT, Flashlight, Halligan, 6’ Hook

Vent from the rear of the store from the exterior

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Old Law Tenement

First due OV (top floor fire)

A

HT, Flashlight, Halligan, SAW

Proceed to roof and if possible, descend FE to provide coordinated vent. If not possible, vent from roof level and assist roof man with roof vent.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Old Law Tenement

First due roof

A

HT, Flashlight, Halligan, Halligan hook, LSR

Position: Roof of the building (Access: Adjoining, Aerial, Rear Fire escape)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Old Law Tenement

Second Due Irons

A

HT, flashlight, Irons, Bunny tool

Door of the apartment directly over the fire apt via interior stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Old Law Tenement

Second Due Can

A

HT, Flashlight, 6’ hook, Can

Apartment directly over the fire apt via the interior stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Old Law Tenement

Second Due Can (Top floor Fire)

A

HT, Flashlight, TWO 6’ Hooks (No can)

Top floor via interior stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Old Law Tenement

Second Due Chauffeur

A

HT, Flashlight, whatever tools chauffeur deems necessary

Position- Front of Fire building. If not needed there, team up w/ second OV (or another available member)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Old Law Tenement

Second Due OV

A

HT, Flashlight, Halligan, 6’ hook

Position: Above the fire (or as needed for rescue) via fire escape, ladder, or adjoining (if party wall balconies)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Old Law Tenement

Second due roof

A

HT, Flashlight, Halligan, Halligan hook

Roof of building (contact 1st due for access)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Old Law Tenement

Second Due Roof (Top Floor Fire)

A

HT, Flashlight, Saw, Halligan Hook (NO HALLIGAN)

Roof of building (contact first due for access)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Non-fireproof MD

Hoseline placements for first alarm assignment:

A

First line: Stretched through interior stairs to fire floor.

Second Line: Stretched through interior stairs to SAME FLOOR AS THE FIRST LINE, if not needed will advance above

Third line: Stretched via fire escape or rope stretch through a window.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Non-fireproof MD fire in an OLT cellar

Hose placements

A

First line stretched to cellar door located inside the building under interior stairway on first floor.

Second Hoseline advanced into the cellar through door in the front or rear

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Fire in a store in a NFPMD

Hose placements (and what size)

A

Stretch 2 1/2” lines

First line into store

Second line stretched into hallway of MD, advance to floor above when assured it is not needed in the store

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Shaft fire in a NFPMD

2nd due chauffeur

A

Position rig to cover the exposed building

If not needed in Fire building, they are available for work in the exposed building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Shaft fire in a NFPMD

2nd due OV

A

If not needed in Fire building, they are available for work in the exposed building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Shaft fire in a NFPMD

2nd due Roof

A

If not needed in Fire building, they are available for work in the exposed building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

HRFPMD

2nd Due Engine

A

One length per FF
Standpipe kit
Post radio (obtain from battalion)

Ensure standpipe is supplied
Take post radio to standpipe outlet where first line being connected
Work with first due to get first line into operation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

HRFPMD

5th Engine Company to Arrive

A

One length of hose per FF
Standpipe kit
High Rise Nozzle (If unit is not equipped w/ HRN contact dispatch for unit that has it)

Report to IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

HRFPMD

CFR engine

A

CFR equipment
Forcible Entry tools

Report to IC and standby with FAST truck

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

HRFPMD

First due LCO, Can and FE

A

Tools: Can, hook, axe, halligan, bunny, search rope, CO meter and TIC

Take elevator to two floors below and notify IC of stairwell closest to fire, type of stairs, if scissor stairs labeled correctly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

HRFPMD

Wind impacted fire, positions of Truck inside team

A

LCO contact outside team, if they report signs of wind impacted fire, remain in stairwell.

If it is not determined to be wind impacted, officer and one member go to control door. Other member remains on HALLWAY side of stairwell door to act as a beacon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

HRFPMD

1st due OV

A

Halligan, hook or axe

If VEIS can be made from outside team with LCC

If no veis, proceed to lobby and use fireman service in elevators

If no fireman service elevators, proceed to fire floor and team up with inside team.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

HRFPMD

1st due Roof

A

Halligan, Bunny and KO curtain

Proceed to apartment directly above the fire apt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

HRFPMD

1st due LCC

A

Chauffeur will select tools deemed necessary to complete assignment

  • If outside operations, team with OV.
  • Deliver LSR to floor above if called for
  • If no outside operations, Rope rescue, or KO curtain deployment, team with 2nd due LCC to go to roof
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

HRFPMD

Second due Inside Team

A

Public hallway of fire floor and ATTACK stairwell for next five floors

Tools: Can, Hook, Irons, Bunny tool, search rope, co monitor, and Thermal Imaging camera

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

HRFPMD

Second Due Inside Team (Wind Driven Fire)

A

Second due LCO must coordinate KO Curtain deployment if it is being used:

  • is assistance needed on floor above?
  • Is a can/hoseline needed for potential extinguishment
  • Are there members in the apartment below to secure the ropes?
  • is there a spotter?
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

HRFPMD

Second due OV

A

Halligan, hook or axe

If outside operations in progress, coordinate with LCC.

If no outside ops, secure another elevator and put in fireman service

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

HRFPMD

Second due Roof

A

Halligan, maul, LSR, and life belt

Proceed to apartment above via attack stair with first due Roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

HRFPMD

Second due LCC

A

Select tools necessary to complete task

If outside ops, team with OV

If LSR or ko curtain being used, assist as needed

If not, proceed to roof with 1st due LCC to vent bulkhead when ordered.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

HRFPMD

3rd Ladder Company to arrive (company responsibilities)

A

Confirm evacuation doorways are CLOSED on fire floor and maintained closed. Position members on stairwell side of door.

If lower floor fire, and first and second due LCCs are tied up with outside ops, third truck assigned to roof.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

HRFPMD

3rd arriving Roof FF

A

Apartment above the fire apt

Normal tool assignment PLUS KO curtain

If first KO Curtain or LSR has been deployed, may be assigned to floor below.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

HRFPMD

FOURTH Ladder Company to arrive (responsibilities)

A

Unit will usually assist or initiate searches on Upper Floors and Staris as determined by IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

HRFPMD

Sixth Ladder Company to arrive

A

Vent support group. Report to IC with two positive pressure ventilation fans

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

LRFPMD

First due inside team

A

Can, Hook, Irons, Bunny, CO meter, TIC

Locate and force entry into fire apt.

Must notify IC if stairs are open or closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

LRFPMD

First due OV

A

Halligan and Halligan hook

Conduct outside survey, if can be reached perform VEIS from exterior.

If out of reach of ladders, team with LCC and search fire floor hallway and assist with search of fire apt.

If 2nd due is delayed the LCO can order them to the apt above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

LRFPMD

First due LCC

A

Halligan and Axe

Conduct outside survey. If within the reach of ladders, team with OV to VEIS.

If out of reach of ladders team with OV to search fire floor hallway and assist with fire apt.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

LRFPMD

First due Roof

A

Halligan, halligan hook, LSR, Life belt

Roof of fire building via:

  1. ) Attached adjoining building
  2. ) Enclosed evacuation stair
  3. ) Aerial or Tower Ladder

(If isolated building w/ only open stairs and stick/bucket can’t reach can go up interior stairs when teamed up)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

LRFPMD

Second due inside team

A

Can, hook, Irons, Bunny, CO meter, TIC, KO CURTAIN (For top floor fire Roof man brings curtain to the roof)

Proceed to apt above the fire apt. Responsible for floors and stairs above the fire.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

LRFPMD

Second due OV

A

Halligan and halligan hook

Conduct outside survey
If in reach of ladders (35’ can hit 4th floor) team with chauffeur
If no outside ops, proceed to floors above fire to assist search

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
44
Q

LRFPMD

Second due LCC

A

Halligan and axe

Conduct outside survey. If outside ops team with OV
If no outside ops, team with OV and search floors above fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
45
Q

LRFPMD

Second due Roof

A

Halligan hook, Halligan, LSR and Life Belt

Proceed to roof to assist 1st due with roof ops

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
46
Q

LRFPMD

Second due roof - top floor fire

A

Halligan Hook, Halligan and KO Curtain

Proceed to roof

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
47
Q

Class 2 building

First due Roof

A

Halligan, Axe/Maul, and Bunny tool

Proceed to roof (order of preference:)

  1. ) Remote/unaffected stair
  2. ) Adjoining building
  3. ) Aerial (not usually viable)
  4. ) Fire Escape
  5. ) Open Stair
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
48
Q

Class 2 building

1st due chauffeur

A

Tools he deems necessary

When no outside ops, team with inside team or try to find secondary entrance to fire apt

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
49
Q

Class 2 building

Second due inside team

A

Can, hook, Halligan, axe/maul, bunny tool, TIC, KO curtain, and search rope

Proceed to apartment above the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
50
Q

Class 2 building

Second due roof

A

Halligan, Halligan hook, LSR and Life Belt

Proceed to roof to assist 1st due Roof man. If Fire is w/in two floors of roof, do not drop rope on floor above, bring to the roof.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
51
Q

Class 2 building

3rd due Truck

A

Confirm evacuation doorways are CLOSED on fire floor and maintained closed. Position members on stairwell side of door.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
52
Q

Class 2 building

4th truck to arrive

A

Search stairwells and upper floors or as assigned by IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
53
Q

HRFPMD

2nd Due Engine

A

One length per FF
Standpipe kit
Post radio (obtain from battalion)

Ensure standpipe is supplied
Take post radio to standpipe outlet where first line being connected
Work with first due to get first line into operation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
54
Q

HRFPMD

5th Engine Company to Arrive

A

One length of hose per FF
Standpipe kit
High Rise Nozzle (If unit is not equipped w/ HRN contact dispatch for unit that has it)

Report to IC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
55
Q

HRFPMD

CFR engine

A

CFR equipment
Forcible Entry tools

Report to IC and standby with FAST truck

56
Q

HRFPMD

First due LCO, Can and FE

A

Tools: Can, hook, axe, halligan, bunny, search rope, CO meter and TIC

Take elevator to two floors below and notify IC of stairwell closest to fire, type of stairs, if scissor stairs labeled correctly

57
Q

HRFPMD

Wind impacted fire, positions of Truck inside team

A

LCO contact outside team, if they report signs of wind impacted fire, remain in stairwell.

If it is not determined to be wind impacted, officer and one member go to control door. Other member remains on HALLWAY side of stairwell door to act as a beacon

58
Q

HRFPMD

1st due OV

A

Halligan, hook or axe

If VEIS can be made from outside team with LCC

If no veis, proceed to lobby and use fireman service in elevators

If no fireman service elevators, proceed to fire floor and team up with inside team.

59
Q

HRFPMD

1st due Roof

A

Halligan, Bunny and KO curtain

Proceed to apartment directly above the fire apt

60
Q

HRFPMD

1st due LCC

A

Chauffeur will select tools deemed necessary to complete assignment

  • If outside operations, team with OV.
  • Deliver LSR to floor above if called for
  • If no outside operations, Rope rescue, or KO curtain deployment, team with 2nd due LCC to go to roof
61
Q

HRFPMD

Second due Inside Team

A

Public hallway of fire floor and ATTACK stairwell for next five floors

Tools: Can, Hook, Irons, Bunny tool, search rope, co monitor, and Thermal Imaging camera

62
Q

HRFPMD

Second Due Inside Team (Wind Driven Fire)

A

Second due LCO must coordinate KO Curtain deployment if it is being used:

  • is assistance needed on floor above?
  • Is a can/hoseline needed for potential extinguishment
  • Are there members in the apartment below to secure the ropes?
  • is there a spotter?
63
Q

HRFPMD

Second due OV

A

Halligan, hook or axe

If outside operations in progress, coordinate with LCC.

If no outside ops, secure another elevator and put in fireman service

64
Q

HRFPMD

Second due Roof

A

Halligan, maul, LSR, and life belt

Proceed to apartment above via attack stair with first due Roof

65
Q

HRFPMD

Second due LCC

A

Select tools necessary to complete task

If outside ops, team with OV

If LSR or ko curtain being used, assist as needed

If not, proceed to roof with 1st due LCC to vent bulkhead when ordered.

66
Q

HRFPMD

3rd Ladder Company to arrive (company responsibilities)

A

Confirm evacuation doorways are CLOSED on fire floor and maintained closed. Position members on stairwell side of door.

If lower floor fire, and first and second due LCCs are tied up with outside ops, third truck assigned to roof.

67
Q

HRFPMD

3rd arriving Roof FF

A

Apartment above the fire apt

Normal tool assignment PLUS KO curtain

If first KO Curtain or LSR has been deployed, may be assigned to floor below.

68
Q

HRFPMD

FOURTH Ladder Company to arrive (responsibilities)

A

Unit will usually assist or initiate searches on Upper Floors and Staris as determined by IC

69
Q

HRFPMD

Sixth Ladder Company to arrive

A

Vent support group. Report to IC with two positive pressure ventilation fans

70
Q

LRFPMD

First due inside team

A

Can, Hook, Irons, Bunny, CO meter, TIC

Locate and force entry into fire apt.

Must notify IC if stairs are open or closed

71
Q

LRFPMD

First due OV

A

Halligan and Halligan hook

Conduct outside survey, if can be reached perform VEIS from exterior.

If out of reach of ladders, team with LCC and search fire floor hallway and assist with search of fire apt.

If 2nd due is delayed the LCO can order them to the apt above

72
Q

LRFPMD

First due LCC

A

Halligan and Axe

Conduct outside survey. If within the reach of ladders, team with OV to VEIS.

If out of reach of ladders team with OV to search fire floor hallway and assist with fire apt.

73
Q

LRFPMD

First due Roof

A

Halligan, halligan hook, LSR, Life belt

Roof of fire building via:

  1. ) Attached adjoining building
  2. ) Enclosed evacuation stair
  3. ) Aerial or Tower Ladder

(If isolated building w/ only open stairs and stick/bucket can’t reach can go up interior stairs when teamed up)

74
Q

LRFPMD

Second due inside team

A

Can, hook, Irons, Bunny, CO meter, TIC, KO CURTAIN (For top floor fire Roof man brings curtain to the roof)

Proceed to apt above the fire apt. Responsible for floors and stairs above the fire.

75
Q

LRFPMD

Second due OV

A

Halligan and halligan hook

Conduct outside survey
If in reach of ladders (35’ can hit 4th floor) team with chauffeur
If no outside ops, proceed to floors above fire to assist search

76
Q

LRFPMD

Second due LCC

A

Halligan and axe

Conduct outside survey. If outside ops team with OV
If no outside ops, team with OV and search floors above fire

77
Q

LRFPMD

Second due Roof

A

Halligan hook, Halligan, LSR and Life Belt

Proceed to roof to assist 1st due with roof ops

78
Q

LRFPMD

Second due roof - top floor fire

A

Halligan Hook, Halligan and KO Curtain

Proceed to roof

79
Q

Class 2 building

First due Roof

A

Halligan, Axe/Maul, and Bunny tool

Proceed to roof (order of preference:)

  1. ) Remote/unaffected stair
  2. ) Adjoining building
  3. ) Aerial (not usually viable)
  4. ) Fire Escape
  5. ) Open Stair
80
Q

Class 2 building

1st due chauffeur

A

Tools he deems necessary

When no outside ops, team with inside team or try to find secondary entrance to fire apt

81
Q

Class 2 building

Second due inside team

A

Can, hook, Halligan, axe/maul, bunny tool, TIC, KO curtain, and search rope

Proceed to apartment above the fire

82
Q

Class 2 building

Second due roof

A

Halligan, Halligan hook, LSR and Life Belt

Proceed to roof to assist 1st due Roof man. If Fire is w/in two floors of roof, do not drop rope on floor above, bring to the roof.

83
Q

Class 2 building

3rd due Truck

A

Confirm evacuation doorways are CLOSED on fire floor and maintained closed. Position members on stairwell side of door.

84
Q

Class 2 building

4th truck to arrive

A

Search stairwells and upper floors or as assigned by IC

85
Q

ERP Incident

First due Ladder Co Officer

A

Supervise Hazard Assessment

Obtain briefing from IC
Assign and instruct teams
Coordinate rig placement with incoming units
Report info to IC

86
Q

ERP Incident

First due LCC

A

Apparatus placement

Position rig out of hazard area and as a barrier for site access control

Remain with apparatus unless ordered

Establish physical barriers for site access

87
Q

ERP Incident

First Ladder Team 1

A
Identify occupancy and location of hazards
Identify container shape and size
Search for shipping docs and MSDS
Identify markings/colors/placards
Provide primary search reports
88
Q

ERP Incident

First Ladder Team 2

A

Back up for team one
Access Hazard Action Guidebook and DOT guidebook
Confirm guide number (confirm w/ second ladder)

89
Q

ERP Incident

Second Ladder Officer

A

Coordinate/Limit Site Access
Obtain briefing from IC
Assign and instruct team assignments
Advise IC of need for Police assistance with site security

90
Q

ERP Incident

Second Ladder LCC

A

Position apparatus out of hazard and as a barrier for site access control
Remain with apparatus unless instructed
Establish physical barrier

91
Q

ERP Incident

Second Ladder Team One

A

Assist first truck with site assessment, back up, or information resources

92
Q

ERP Incident

Second Ladder Team Two

A

On orders of the officer, establish initial exclusion zone using RED barrier tape, utility rope, cones, etc.

Remain outside exclusion zone

93
Q

ERP Incident

First arriving Engine Company

A

Establish initial water supply

Stretch a line but do not place into operation until orders by IC

Members will remain together as a unit

If necessary members of first engine can perform CFR

94
Q

ERP Incidents

Second arriving Engine Company

A

Coordinate with second due ladder for site access control

Remain together as a unit

May help first due engine with water supply, line placement, site access, or evacuation

If necessary members of second arriving engine may perform CFRD

95
Q

ERP Incidents

Third arriving Engine Company

A

Third arriving engine company should be assigned CFRD duties

96
Q

Collapse Operations

First due engine

A

Water supply

Stretch 2 1/2” line to cover entire collapse site

CONSIDER stretching a 3 1/2” supply line to a TL

97
Q

Collapse Operations

Second due engine

A

ENSURE a 3 1/2” supply line stretched to a TL

Assist 1st due engine company stretch

May perform CFRD

98
Q

Collapse Operations

Third due engine

A

Stretch additional lines
Augment water supply
Perform CFRD
Assist in removing lightly buried victims

99
Q

Collapse Operations

First due ladder company

A

(Officers have the option of splitting company to cover more area)

Recon
Remove surface victims
Perform preliminary void search
Bring victims to Casuatly Collection Point

100
Q

Collapse Operations

Second due ladder company

A

Immediately begin controlling gas, electric and water services

Ensure that dispatcher notified utility crews

101
Q

Chemical Attack in Underground Transit System

First Ladder Team One (Officer and Two FF)

A

Evacuation and Hazard Assessment

(EH - Every Helmet Becker Uses Eventually Gets Salty)

DO NOT ENTER A SUBWAY WHERE VISIBLE PERSONS ARE UNRESPONSIVE

102
Q

Chemical Attack in Underground Transit System

First Ladder Team Two

A

Back Up for Team One and establish communication relay until relieved by CPC equipped unit

(BU - Every Helmet Becker Uses Eventually Gets Salty)

103
Q

Chemical Attack in Underground Transit System

Second Ladder Team One

A

Evacuation to Gross Decon

EG- Every Helmet Becker Uses Eventually Gets Salty

104
Q

Chemical Attack in Underground Transit System

Second Ladder Team Two

A

Site Access Control

S- Every Helmet Becker Uses Eventually Gets Salty

105
Q

Brownstone

First due inside team

A

Proceed to seat of the fire and conduct thorough primary search

First member through doors chicks open.

106
Q

Brownstone

First due LCC

A

Front of building- must be able to return to pedestal or to reposition rig (MUST notify officer if leaving this position)

  • Raise aerial
  • Wait for roof size up
    (1) Assist with LSR rescue if needed
    (2) If no LSR rescues, position aerial to top floor to VEIS (team with 2nd due LCC)
    (3) When fire blocks interior stairway and no rear fire escape, top floor VEIS is MANDATORY

Tools: HT/Flashlight/Tools the LCC deems necessary

107
Q

Brownstone

First due LCC - Top Floor Fire

A

Raise and position aerial to roof of exposure for roof and OV

Vent top floor windows

Inside team will make contact with LCC (or show at windows) to confirm they made it to top floor. If no contact LCC should attempt entry and search

108
Q

Brownstone

First due OV

A

Tools - 6’ hook, halligan, flashlight

  • Assist LCC with rig positioning and/or portable ladders
  • Check rear for trapped occupants
  • If TL, operate in the bucket
109
Q

Brownstone

First due OV - Top Floor Fire

A

Tools- Saw, Halligan

Position- Take saw to the roof

110
Q

Brownstone

First due roof

A

Tools- Halligan, Halligan hook, LSR

Position - Roof of fire building (1st due aerial, 2nd due aerial, adjoining building)

Vent skylights
Open roof scuttle covers
Vent windows on upper floors
(IF FE PRESENT) Team with OV to VEIS upper floors

111
Q

Brownstones

Second due Inside Team

A

Go to floor(s) above to VEIS

If blocked by interior can order access from portable ladder

112
Q

Brownstone

Second due inside team - Top Floor Fire

A

Check the floors BELOW in fire building to ensure fire did not start below.

Be available to assist or relieve first due truck on fire floor

Remain on floor below until needed- do not block halls or stairway

113
Q

Brownstone

Second due LCC

A

Tools: HT/ Flahslight/ Tools deemed necessary

Position rig and place in PTO for use by roof

Team with first LCC for top floor VEIS

When no longer needed for laddering in front of building, operate where company officer directs

114
Q

Brownstone

Second due OV

A

Tools- 6’ hook, Halligan, flashlight, HT

Position- check the rear (especially important if first due is TL)

Return to front if there is a need to get above via portable or aerial

115
Q

Brownstone

Second due OV - Top floor fire

A

Tools- 6’ hook and Halligan

Position- check the rear

After checking the rear, proceed to roof to help vent or go into an exposure as directed by officer

116
Q

Brownstone

Second due Roof

A

Tools- Halligan, Halligan Hook (No saw unless for top floor fires)

Position- roof of fire building

  • confirm roof vent
  • check for rear fire escape
  • when necessary perform initial vent of roof of exposure
117
Q

Brownstone

Second due roof - top floor fire

A

Tools- Halligan Hook, Saw

118
Q

Brownstone

First due OV (Tower Ladder)

A

Tools - Halligan and 6’ hook

Operate from bucket

When bucket used to drop off roof man, wait for size up, vent fire floor, then VEIS top floor

119
Q

Row frame

First due inside team

A

First member through door chicks open

Maintain control of fire door, proceed to seat of fire and primary search.

120
Q

Row frame (Brownstone Layout)

First due LCC (stick)

A

Tools: LCC selects tools as deemed necessary

Position: Front of building.

Raise aerial to roofe, wait for completion of roof size up. If LSR rescue, proceed to roof to assist. If no LSR, place aerial to top floor for VEIS

121
Q

Row frame (OLT Type)

First due LCC

A

Tools: LCC selects tools as deemed necessary

Position: Front of building.

Position rig for full building coverage, raise portables/aerial for rescue, raise aerial for roof access.

If fire is on 3/4/5 floor, reposition aerial to VEIS fire apartment when teamed with 2nd due chauffeur

If fire is on 1/2 floor, VEIS fire apartment with portables when teamed with 2nd due LCC

122
Q

Row frame

First due OV

A

Tools: 6’ hook, Halligan

Position: vent fire apartment from the exterior. When no front ladder rescue required, immediately make way to the rear and vent floor within reach

123
Q

Row frame (top floor)

First due OV

A

Tools: Saw and Halligan

Position: Proceed to roof with saw, and when possible descend fire escape to VEIS

124
Q

Row frame

First due roof

A

Tools: Halligan, Halligan hook, LSR

Roof access: Aerial, second due aerial, adjoining (NOT IMMEDIATE ADJOINING) building

Survey rear and shafts, vent skylights, open scuttle covers, vent windows on upper floors

125
Q

Row Frame - Brownstone Type (Top Floor)

Second due inside team

A

Tools: Can should consider taking two hooks in lieu of can.

Position - top floor of most severely threatened exposure.

Determine if fire can be stopped in this building, if so, call for a handline. If fire can not be stopped in this building, move to additional exposures

126
Q

Row frame - brownstone type (top floor)

Second due LCC

A

Tools: As deemed necessary by LCC

Position: position rig for rescue purposes and/or roof access. When no longer needed at aerial, go to exposure as directed by officer and examine cockloft

127
Q

Row frame - brownstone type (top floor)

Second due OV

A

Tools: 6’ hook, Halligan

Position: check rear. If fire escape present, operate in rear. If no fire escape, team up with chauffeur to examine exposure or proceed to the roof.

128
Q

Row frame- brownstone type (top floor)

Second due roof

A

Tools- Saw and Halligan hook

Go to roof, cut so at least two rooms will be vented. Make examination holes in returns of the exposures

129
Q

Row frame - OLT type (top floor)

Second due inside team

A

Tools: Same

Position: Top floor fire building, in apartment adjacent to fire apartment

130
Q

Row frame - OLT Type (Top Floor)

Second due LCC

A

Tools: As deemed appropriate by LCC

Position: Front of building. If not needed at the aerial or for laddering front of building, go to an exposure as directed by officer.

131
Q

Row frame OLT Type (Top floor)

Second due OV

A

Tools: Halligan and Hook

Position: Fire escape to VEIS top floor with 1st due OV

132
Q

Row frame OLT Type (top floor)

Second due Roof

A

Tools: Saw and Halligan hook

Position: Roof of fire building

133
Q

Row frame OLT & Brownstone

First due LCC (Tower Ladder)

A

Tools: As deemed necessary by LCC

Position: remain at pedestal

134
Q

Row frame Brownstone Type

First due OV (Tower Ladder)

A

Tools: Halligan and Hook

Position: Operate from bucket. Drop off roof and wait for size up, then reposition to fire floor to VEIS. After fire floor, VEIS top floor from bucket.

135
Q

Row frame OLT Type

First due OV (Tower Ladder)

A

Tools: Halligan & Hook

Position: Operate from bucket. Wait for roof size up and then VEIS fire floor