Pneumatic Distribution Flashcards
Lower Stage of Compressor = ?
High RPM
Higher Stage of Compressor = ?
Low RPM
What pressure is taken first in an Engine
Lower
What does a High Pressure Control Valve do
Used to determine the source of engine compressor stage
What does a Ground Pneumatic Connection do
Acts as a Pneumatic Hose Adaptor with intergrated Check Valve
What does a LP Check Valve do
Prevents reverse flow to the engine low stage compressor
What does a Fan Air Valve do
Regulates Pneumatic Supply Temp
What does a Pressure Regulating Valve do
Shuts off or Regulates the Pneumatic supply pressure
What does a Over Pressure Valve do
Closes incase of malfunction of the Pressure Regulating Valve
What does a Heat Exchanger do
Used to cool pneumatic air with air fan
What does a Isolation Valve do
Split or Connect the different Pneumatic Systems
What does a APU Bleed Valve do
Shuts off or Allow APU Bleed air supply
What does a Manifold Fail Sensing Element do
Used to detect bleed air leaks or duct rupture
How is High Pressure Control Valve CONTROLLED
Electrically
How is High Pressure Control Valve ACTUATED
Pneumatically
INDICATIONS AND WARNINGS:
Pneum Temp HI
Pneumatic Temp over 255 degrees C
INDICATIONS AND WARNINGS:
Pneum Manf Fail
Duct Rupture or Leak
INDICATIONS AND WARNINGS:
Pneum Abnorm
Pressure is less than 37 psi
Or greater than 57 psi
INDICATIONS AND WARNINGS:
Use ENG Pneum Supply
Reminder to use Engine Airsupply if APU is supplying Air