Plumbing Fixtures and Aplliances Flashcards
Siphon jet water closets are wall hung only
False
The opening of the basin (top of the flish rim) of a barrier-free wall hung urinal must be no more than 430 mm above the finish floor
True
Ledge laboratories support themselves better than raised back, wall hung laboratories
False
Overrim bathtub faucets are always compression faucets
False
The ideal temperature for drinking water is 10゚C
True
The maximum acceptable level for water hardness is 8.6 gpg
False
Total daily water consumption is based on an average water consumption of 60 gallons per day per person
True
T&P relief valves for domestic water heaters are set to open at 90゚C
True
The NBC specifies that floor set and wall hung water closets must have a minimum spacing of _____ mm on either side of the center of the water closet flange to a wall or another fixture to allow freedom of movements
380mm
A _____ water closet/urinal has a non-siphonic passageway at the rear of the bowl and an integral flush rim and priming jets
Blowout
According to the NBC an accessible water closet stall must be not less than _____
1500 mm wide by 1500 mm deep
The maximum volume of water used for flushing urinals is _____ liters per flush
3.8 Liters
A _____ faucet is a faucet in which the flow of water is shut off by means of a washer at the base of a valve stem assembly
Compression
A barrier-free bathtub must be equipped with _____ grab bars
Three
A _____ waste and overflow is combination waste and overflow device that consists of a stopper that is raised and lowered by pushing on it
Clicker