Plumbing code-review Flashcards
- What do you call a receptacle installed to collect and drain storm water
from an open area?
a. area drain
b. storm sewer
c. floor drain
d. split drain
A
What is the PRC Resolution Number is issued by the Board of Master
Plumbing for the adoption and promulgation of the Revised National Plumbing
Code of the Philippines?
a. Res. No. 2
b. Res. No. 1378
c. Res. No. 4
d. Res. No. 962
C
All water supply, drainage, venting system and all fixture and their traps
complete with their connection.
a. plumbing system
b. piping system
c. sewer system
d. sanitary system
A
The minimum size of water supply pipe to a lavatory is
a. 1-inch diameter
b. 2/4-inch diameter
c. 3/8-inch diameter
d. ½-inch diameter
C
What interior pipes are used to convey storm water from a roof drain to a
point of disposal?
a. leaders
b. conductors
c. storm stacks
d. wet stack
B
A means of measurement for vertical waste or soil stack. It is equal to
each floor level or storey in a building but are always at least eight feet
intervals.
a. Vertical distance
b. Floor distance
c. Branch intervals
d. Storey
C
A drain connecting the compartments of a certain fixture to its trap is
called.
a. Combination waste and vent
b. Continuous waste
c. Special waste
d. Indirect waste
B
Curriculum for plumbing engineering was first introduced at ______.
a. FEATI University
b. Adamson University
c. University of the Philippines
d. National University
A
The diameter of waste and overflow for a bathtub shall not be less than
______.
a. 1-1/4” OD
b. 1-3/8” OD
c. 1-1/2” OD
d. 1-3/8” OD
C
The minimum pressure that should be maintained for fixtures containing
flush tank supplies shall be ______.
a. 8 psi
b. 4.34 psi
c. 30 psi
d. 0.434 psi
A
No water closet shall be located in a room or compartment which is not
properly lighted and ventilated.
a. Principle No. 12
b. Principle No. 16
c. Principle No.
18 d. Principle No. 22
B
A vertical shaft for the installation of different pipe stacks.
a. Section 201.6
b. Section 202.6
c. Section 203.6
d. Section 204.6
D
Supports or Anchorage of piping shall not exceed an interval of
a. 10 ft.
b. 12 ft.
c. 20 ft.
d. 15 ft.
A
A pipe connected from building gutter to the downspout or conductor.
a. Section 210.6
b. Section 211.6
c. Section 212.6
d. Section 213.6
D
Tube made of plastic material and colored black. The cross-sectional
shape is oval and is denoted by its outside diameter or O.D. Normally used
as a water service connection from main to meter.
a. polybutylene
b. polyethylene
c. PVC
d. polypropylene
A
A receptacle in which liquids are retained for a sufficient period of time to
allow settable material to deposit.
a. septic tank
b. pit privy
c. cesspool
d. catch basin
D
When connecting plastic pipe to other types of piping, the specific transition intended shall be made with approved.
a. Soldered joint
b. threaded joint
c. Fittings and adaptors
d. sweated joint
C
The inspection of a gas piping system prior to covering or concealing such pipe is called a
a. routine inspection
b. hydro piping inspection
c. site inspection
d. rough piping inspection
D
Lead pipes shall be supported at intervals not exceeding _____ at centers with rigid vertical backup.
a. 1.0 m
b. 1.2 m
c. 1.5 m
d. 1.8 m
B
The minimum air gap for effective openings not greater than 25mm in
diameter affected by walls
a. 2 times
b. 3 times
c. 1.5 times
d. 2.5 times
B
Vent pipes may offset horizontally when the distance above the extreme
overflow level of the fixture is at least.
a. 1 inch
b. 6 inches
c. 18 inches
d. 1 foot
B
Cast iron piping in 10 ft. lengths installed horizontally, shall be supported
at intervals of not more than.
a. 12 ft.
b. 15 ft.
c. 5 ft.
d. 10 ft.
D
Drainage pipes shall be run in practical alignments & at a uniform slope
between manholes of not less than _______ toward the point of disposal
a. 20mm/m
b. 40mm/m
c. 30mm/m
d. 10mm/m
A
A drainage pipe used to carry main or surface water, cooling water, and
similar liquid waste is
a. House drain
b. House sewer
c. Sanitary sewer
d. Storm sewer
D
Copper tubing shall be supported at each storey or at maximum intervals
of _____ on centers.
a. 1.5 m
b. 2.0 m
c. 3.0 m
d. 1.8 m
C
A receptacle attached to the Plumbing System other than the trap in
which waste or waste may be collected or retained for an ultimate discharge
into the Plumbing system.
a. Container
b.Fixture
c. Tank
d. Cesspool
B
Shielded coupling joints
a. Section 1202.17
b. Section 1302.17
c. Section 1203.17
d. Section 1303.17
B
According to the existing Plumbing Code cast iron pipes, wrought iron
pipes, weld steel pipes, copper pipes, vitrified clay, concrete and asbestos
pipes shall conform to standard other than the Philippine standard.
a. ANSI
b. AISC
c. ASTM
d. API
C
Excessive water pressure - water pressure greater than_______ kPa
a. 551
b. 552
c. 553
d. 554
A
The minimum allowable size of any building drain, horizontal branch
vertical soil or waste stack serving one or more water closets shall be.
a. 4”
b. 3 ½“
c. 3”
d. 5“
D
The vent pipe serving a combination waste and vent system with a 4-inch
drainpipe shall be at least
a. 2 1/2 inches
b. 3 1/2 inches
c. 3 inches
d. 2 inches
D
The drainage pipe running from outside a building foundation to the main
sewer is called
a. building drain
b. Sewer
c. Waster drain
d. Storm drain
B
A set of regulation adapted by an administrative agency that has
jurisdiction over materials and design specification in plumbing.
a. Plumbing Code
b. Code of Ethics
c. Building Code
d. Civil Code
A
The maximum lead content allowed in pipe used to convey potable water.
a. 3 percent
b. 2 percent
c. 1 percent
d. 8 percent
D
The maximum fixture units loading allowed on a 2 – inch waste stack is.
a. four
b. six
c. sixteen
d. eight
C
A device used to connect drainage of a dishwasher with the sanitary
drainage system is called.
a. Wastewater device
b. Vacuum Breaker
c. Explosive device
d. Air gap device
D
That part of the lowest horizontal piping of the plumbing system which
receives the discharge from soil, waste and other drainage pipes inside of the
building and conveys it to the house sewer.
a. Vertical drain
b. Storm drain
c. House drain
d. Soil pipe
C
Piping which shall NOT be installed under or within 2 ft at any building or
structure is:
a. cast iron
b. copper
c. plastic
d. Asbestos cement
D
What valve is required ahead of each water supplied appliance, each slip
joints or non – metallic connections?
a. Flow valve
b. Check valve
c. Control valve
d. solenoid valve
C
PD No. 1185 is another law that Master Plumbers used as their guide in
the practice of the plumbing profession. What is PD No. 1185?
a. Accessibilty Law
b. Fire Code of the Philippines
c. Water Code of the Philippines
d. Code of Sanitatio
B