The required clearance in front of a 2” clean out is?
18”
PVC shall be supported horizontally every Ft?
4
The maximum horizontal distance of a trap arm is measured from the inner edge of the vent to the?
Weir of the trap
Pex piping 1” and smaller shall be supported horizontal every How many feet?
32”
The required distance in front of a3” clean out is?
24”
The minimum size trap for a kitchen sink is?
11/2”
The minimum size for a kitchen waste is?
2’
A sewage ejector line shall be provided with a?
Back water valve and gate valve
The maximum number of water closets on 3” stack is?
4
The max length for a 11/2 pipe is?
60’
A plumbing vent shall not terminate through the roof not less then?
10’
Drinking fountains may be installed with a?
Indirect waste
11/2 trap arm can’t exceed
42”
2” trap arm can’t exceed
60”
3” trap arm can not exceed
72”