PLUMBING Flashcards
IS THE ART AND TECHNIQUE OF INSTALLING PIPES, FIXTURES, AND OTHER APPARATUSES IN BUILDINGS FROM BRINGING IN THE SUPPLY, LIQUIDS, SUBSTANCES, AND/OR INGREDIENTS AND REMOVING THEM; AND SUCH WATER, LIQUID, AND OTHER CARRIED-WASTES HAZARDOUS TO HEALTH, SANITATION, LIFE, PROPERTY, ALSO THE PIPES AND FIXTURES AFTER INSTALLATION I.E. THE PLUMBING SYSTEM
PLUMBING
22 PRINCIPLES OF PLUMBING
- CLEAN WATER
- VOLUME AND PRESSURE
- EFFICIENCY
- EXPLOSION
- SEWER
- PLUMBING UNIT
- VENTILATION
- CLEAN OUTS
- NAMPAP
- TRAP
- AIR CIRCULATION
- VENTI TERMINALS
- TESTS
- SEWAGE HARM
- CONTAMINATION
- WC LIGHT
- SEPTIC TANK
- SEWAGE BACKFLOW
- RMP
- ACCESSIBLE
- STRUCTURAL STABILITY
- SEWAGE TREATMENT
PLUMBING CYCLE
SOURCE - SUPPLY - DISTRIBUTION - USE - COLLECTION - DISPOSAL - TREATMENT - SOURCE.
7 PLUMBING SYSTEM COMPONENTS
WATER SERVICE ENTRANCE
WATER METER
MAIN DISTRIBUTION PIPE
BRANCH PIPE (FIXTURE)
RISER
VALVES AND CONTROL
STORAGE TANKS
PLUMBING FIXTURES
SOIL FIXTURE
SCULLERY FIXTURE
BATHING FIXTURE
THESE FIXTURES ARE RESPONSIBLE FOR THE COLLECTION OF VARIOUS WASTE WATER THAT SHALL BE DISPOSED IN SOIL PIPES
SOIL FIXTURES
WATER CLOSETS ACCORDING TO FLUSHING
DIRECT FLUSH VALVE WATER CLOSET
WATER CLOSETS ACCORDING TO FLUSH TANK TYPE
INTEGRAL FLUSH TANK WATER CLOSET
CLOSE COUPLED FLUSH TANK WATER CLOSET
HIGH FLUSH TANK WATER CLOSET
WATER CLOSETS ACCORDING TO MOUNTING
FLOOR MOUNTED WATER CLOSET
WALL HUNG WATER CLOSET
OTHER TYPES OF WATER CLOSET
SQUAT TYPE WATER CLOSET
WASH OUT WATER CLOSET
WATER CLOSETS ARE SET FROM ITS CENTER TO THE SURFACE OF A SIDE WALL WITH A MINIMUM DISTANCE OF 0.375 M. CENTER-TO-CENTER SPACING OF WATER CLOSETS ARE SET AT A MINIMUM OF 0.75M
SETTING WATER CLOSETS
SETTING WATER CLOSETS
WATER CLOSETS ARE SET FROM ITS CENTER TO THE SURFACE OF A SIDE WALL WITH A MINIMUM DISTANCE OF 0.375 M. CENTER-TO-CENTER SPACING OF WATER CLOSETS ARE SET AT A MINIMUM OF 0.75 M
TYPE OF URINALS ARE SPECIFIED AS WALL HUNG, PEDESTAL, TROUGH, AND STALL. URINALS ARE SET 0.30 M FROM ITS CENTER TO THE SURFACE OF A SIDE WALL. 0.60 M IS THE MINIMUM CENTER-TO-CENTER DISTANCE SET BETWEEN TWO URINALS
URINALS
SOIL FIXTURES: URINALS
WALL HUNG URINAL
PEDESTAL URINAL
THESE FIXTURES CONSISTS OF THOSE THAT ARE RESPONSIBLE FOR KITCHEN, DINING, AND COOKING UTENSILS I.E. KITCHEN SINKS, AND WASHING VARIOUS MATERIALS OR SMALL ITEMS I.E. LAVATORIES, LAUNDRY AREAS
SCULLERY FIXTURE
TYPES OF SCULLERY FIXTURE
KITCHEN SINK
LAUNDRY TUB
LAVATORIES
TYPES OF LAVATORIES
PEDESTAL LAVATORY
COUNTER TOP LAVATORY
WALL HUNG LAVATORY
THESE FIXTURES ARE PRIMARILY RESPONSIBLE FOR BATHING. THESE FIXTURES COMMONLY DISCHARGES VARIOUS GREY WASTE WATER THROUGH WASTE PIPES. BATHING FIXTURES INCLUDE: BATH TUBS, WHIRL POOL BATHS, JACCUZZI, BIDETS.
BATHING FIXTURES
ARE SET AT 0.375 M FROM THE CENTER OF BIDET TO THE SURFACE OF A SIDE WALL, AND 0.75 M MINIMUM CENTER-TO-CENTER DISTANCE SET BETWEEN BIDETS.
BIDET
SHOWER RECEPTORS, DAMS, CURBS, ARE INSTALLED IN THE BATHROOM TO PREVENT THE ESCAPE OF WATER THAT MIGHT OVERFLOW OR FLOOD INSIDE THE BATHROOM DURING BATH.
FLOOR DRAIN
SHOWER COMPARTMENTS SHOULD HAVE A MINIMUM INTERIOR AREA OF 0.6 M^2 AND SHALL BE CAPABLE OF ENCOMPASSING A 762 MM DIAMETER CIRCLE
SHOWER COMPARTMENT
TRUE OR FALSE:
ONLE ONE TRAP SHALL BE PERMITTED ON A TRAP ARM
TRUE
TRUE OR FALSE:
IN NO CASE SHALL THE TRAP DISTANCE BE LESS THAN 2 TIMES THE DIAMETER OF THE TRAP ARM
TRUE