PLANT TISSUE CULTURE LAB Flashcards

1
Q

Growth of protoplasts, cells, tissues, shoot tips, roots, anthers, embryos, flowers and meristems in a laboratory medium.

A

Tissue culture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

any nutrient material prepared for the growth and cultivation plant tissue.

A

culture medium

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

process of making any material entirely free from living microorganism.

A

sterilization

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

condition that describes the freedom of plant materials, culture medium, confines of the culture vessel from contaminating microorganisms.

A

asepsis

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

subjecting of cultures to conditions favorable to the growth of the plant tissue

A

incubation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

flow air currents in which air currents do not intermingle

A

laminar flow

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

(CEILINGS) Ceilings shall be at least ______ from the finished floor line.

A

2.4 m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

(WALL) All wall tops and ledges shall slope at ______.

A

45 degree

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

(WALL) It should be coved to the floor-wall and at wall-to-wall junctions with a radius of __________.

A

50 mm - 60 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

(WINDOWS) All windows shall be properly installed with _________.

A

16-mesh screen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

(WINDOWS) Windowsill shall be at least _______ from the finish floor line.

A

1 m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

(DOORS) Main doorways shall be at least _______ wide to allow easier movement of large equipment and facilities.

A

1.5 m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

(DOORS) Door for staff, storage and chemical rooms should be at least ________.

A

0.8 m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

(FLOOR) The floor slope should be ________ towards the drain.

A

2% - 4%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

(MEDIA PREPERATION AND STERILIZATION AREA) The area shall be provided with working tables. Tables should be up to ______ wide if
it is to be access from both sides, and should not exceed _______ if it is accessible only from one side and the height should be ________.

A

1.2 m , 600 mm , 850 mm – 900 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

(GROWTH ROOM) Ceilings shall be insulated with a minimum R-value of ________.

A

2.64

17
Q

(LIGHTING) Artificial lighting should be provided for the production of photo-period sensitive plants. For the workers, _______ should be provided.

A

200 lux

18
Q

(GROWTH ROOM) The width of the shelves should be _________ if accessible only from one side and should be _________ if accessible from both sides. The distance between each layer of the shelves shall be _________.

A

405 mm , 1 m , 455 mm

19
Q

(GROWTH ROOM) Aisles and passage shall be at least ________.

A

1 m

20
Q

(LIGHTING) Outside the laboratory.

A

100 lux

21
Q

(LIGHTING) General

A

200 lux

22
Q

(LIGHTING) Working table

A

500 lux

23
Q

(LIGHTING) Growth room

A

100 - 1000 lux

24
Q
A