Physics Quiz 1 Flashcards

1
Q

What is the technique where multiple sound beams are emitted from the transducer from different angles to create one image?

A

Compound imaging

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

An increase in (blank) would reduce image noise.

A

Persistence

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Assuming all of these were in use, which scan converter matrix would have the best memory spatial resolution?
8 bit
12 bit
2 bit
5 bit

A

12 bit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many shades of gray is a four bit digital scan converter capable of storing?

A

16 shades

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The process of smoothing (spatial averaging) is a technique…

A

Where values in the surrounding pixels are used to calculate a new value for the pixel of interest.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Which instrument component can usually handle the widest range of echo signal amplitudes?

A

Receiver

(Also called the signal processor)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The binary number 1001001 represents what number?

A

73

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What technique is used to fill in missing data?

A

Interpolation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If there were no attenuation in tissue, what would not be needed?

A

Compensation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When comparing gray scale and bistable imaging systems, what does a gray scale imaging system display when not seen with a bistable system?

A

A range of reflection amplitudes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

True/False

Dynamic range of the receiver is the ratio of the largest to smallest intensity the machine can handle.

A

False

(Largest to smallest AMPLITUDE)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

This function in the receiver takes the negative half of a signal and turns it into a positive voltage

A

Rectification

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What would the number 392 be represented as in the binary system?

A

110001000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Which zoom method improves spatial resolution?

A

Write magnification

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

True/False

Interlaced monitors yield higher frame rates than the non-interlaced monitors.

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The maximum frame rate permitted for a 15-cm penetration depth, three focuses, and 200 scan lines per frame is approximately ____

A

8.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

A change of the shape of the electrical signal into a video form is termed ______________.

A

Demodulation

18
Q

What is the term used to describe the picture elements?

19
Q

PACS stands for (blank)

A

Picture archiving and communications system

20
Q

The ability of a gray-scale display to distinguish between echoes of slightly different intensities is called (blank)

A

Contract resolution

21
Q

The ______ carries out filtering, detection, and compression.

A

Signal processor

22
Q

At a distance of two near zone lengths, the beam diameter is ______ the transducer diameter

23
Q

Ultrasound transducers operate according to ______________.

A

The piezoelectric principle.

24
Q

Axial resolution is:

A

The minimum reparation necessary to resolve reflectors along the scan line.

25
Q

The (blank) determines how amplification is accomplished in the amplifier.

A

Gain control

26
Q

Pixel interpolation, persistence, and panoramic imaging are examples of (blank)

A

Preprocessing functions

27
Q

True/False

A highly compressed signal will have greater contrast resolution.

28
Q

True/False

If the penetration is increased the PRF must be increased.

29
Q

What is the function of compression in an ultrasound unit?

A

Reduce the signal amplitude differences

30
Q

The advantage of the super VHS format compared with the standard VHS format is that:

A

Spatial detail is improved

31
Q

True/False

Teleradiology is the electronic transfer of images via coaxial cables, email, or telephone lines.

A

False

(Images are not sent via email)

32
Q

True/False:

Ultrasound images printed using a thermal processor have poorer resolution and fewer shades of gray compared to an x-ray film.

33
Q

(Blank) is the number of complete cycles per second

34
Q

Sound requires a _____________ through which to travel

35
Q

If frequency increases, period will (blank)

36
Q

Wavelength is the (blank) over which one cycle occurs

37
Q

Propagation speed is the speed at which a wave (blank) through a medium

38
Q

Stiffer media have (blank) sound speeds

39
Q

Ultrasound pulses contain a range of frequencies called the (blank)

40
Q

Pulsed ultrasound consists of (blank) separated by (blank) of time

A

Pulses ; gaps

41
Q

All of the following are acoustic variables except:

  • density
  • particle motion
  • compression
  • pressure
A

Compression is not an acoustic variable