Accident prevention relies on all but one of the following:
a) good housekeeping
b) proper use of ladders
c) knowledge of first aid
d) proper use of handrail
c) knowledge of first aid
An electric current passing through the body for one second or more is generally fatal if the current intensity is:
a) 1 milliamp
b) 5 milliamps
c) 10 milliamps
d) 100 milliamps
d) 100 milliamps
An electrical circuit should be treated as it is energized until:
a) the circuit breaker in indicated open
b) the disconnect is indicated open
c) the circuit is proven de-energized
d) the DC is open to the control circuit
c) the circuit is proven de-energized
The distance at which the foot of the ladder should be placed from the wall is:
a) 1/4 the length of the ladder
b) 1/4 the length of the ladder to the top of the support
c) 1/4 the height of the wall
d) 4 times the ladder width
b) 1/4 the lengyth of the ladder to the top support
Unless protection is provided by other means, a scaffold plan should not overhang its support b more than:
a) 6”
b) 12”
c) 18”
d) 24”
c) 18”
For removing hazardous vapor from the air, a chlorine respirator would use a:
a) chemical filter
b) mechanical filter
c) particulate filter
d) chemical filter
a) chemical filter
The Oxygen Breathing Apparatus will provide raspatory protection, under hard work, for a minimum period of:
a) 30 mins
b) 45 mins
c) 60 mins
d) 90 mins
b) 45 mins
The Scott Air-Pak II will provide respiratory protection for a period of approximately:
30 mins
In general, the first thing you should do to help a victim of a severe accident is:
a) call doctor
b) call ambulance
c) keep them warm
d) keep them lying down
d) keep them lying down
A good defensive driver knows that a safe following distance to maintain with driving at 60mph is:
a) 40 ft
b) 80 ft
c) 120 ft
d) 180 ft
c) 120 ft
Fires involving wood, textiles, paper, rubbish, and the like are:
a) class A
b) class B
c) class C
d) class D
a) class A
Fires involving flammable liquids such as gasoline, oils, and grease are:
a) class A
b) class B
c) class C
d) class D
b) class B
Dry chemical extinguishers do not have the cooling and quenching effect usually need to quench:
a) class A fires
b) class B fires
c) class C fires
d) class D fires
a) class A fires
The max effective range of 150lb dry chem extinguisher is about:
a) 5ft
b) 25ft
c) 50ft
d) 70ft
b) 25ft
The duration of discharge of a 20lb CO2 fire extinguisher is about:
a) 5 seconds
b) 10 seconds
c) 45 seconds
d) 60 seconds
c) 45 seconds