Phenom 100 Recall Items Flashcards
SMOKE/FIRE/FUMES (AFM 4-30 p3, QRH S1-2)
Oxygen Masks—DON, EMER
EMER then 100% after 2 minutes.
Dilution Valve—CLOSED
Smoke Goggles—DON
Communication—ESTABLISH
Dump Button—Push In
SMOKE EVACUATION (AFM4-30 p5, QRH S1-7)
Oxygen Masks—DON, EMER
EMER then 100% after 2 minutes.
Dilution valve---CLOSED Smoke Goggles (if available)---DON Communication---ESTABLISH Oxygen Knob---CREW ONLY DUMP Button---PUSH IN BLEED Knob---OFF VENT
EMERGENCY EVACUATION (AFM 4-01 p7, QRH NAP 1-5)
Thrust Levers---IDLE Emergency/Park Brake---ON START/STOP knobs---STOP Shutoff 1 & 2 Buttons---PUSH IN Pressurisation MODE switch---MAN Pressurization DUMP Button---PUSH IN ATC---NOTIFY Emergency Evacuation---PERFORM BATT 1 & 2 Switches---OFF
ENGINE ABNORMAL START (AFM 4-01 p8, QRH NAP 1-5)
Affected Engine;
START/STOP knob—STOP
ENGINE FIRE, SEVERE DAMAGE OR SEPARATION
AFM 4-01 p8A, QRH NAP 1-6
Affected Engine:
Thrust Lever—IDLE
START/STOP Knob—STOP
Shutoff Button—PUSH IN
Wait 30 seconds and if fire persists;
BOTTLE Switch—-DISCH
DUAL ENGINE FAILURE (AFM 4-01 p6, QRH NAP 1-3)
Thrust Levers—IDLE
Oxygen Masks—DON
Communication—ESTABLISH
REJECTED TAKEOFF AT OR BELOW V1 (AFM 4-01 P9)
Thrust Levers—IDLE
CABIN ALTITUDE HI (AFM 4-04 p3, QRH EAP 2-3)
Oxygen Masks---DON 100% Communication---ESTABLISH SIGNS/OUTLET switch---PED-BELTS/OFF Altitude---MAX 10,000 or MEA whichever is higher Thrust Levers---IDLE Airspeed---MAX 250 KIAS/Mmo Max. LDG GEAR Lever---DOWN Airspeed---MAX 275 KIAS/Mmo Max. Transponder---7700 ATC---NOTIFY
EMERGENCY DESCENT (AFM 4-01 p7, QRH NAP 1-4)
SIGNS/OUTLETS switch---PED-BELTS/OFF Altitude---MAX 10,000 or MEA whichever is higher Thrust Levers---IDLE Airspeed---250 KIAS/Mmo LDG GEAR---DOWN Airspeed---275 KIAS/Mmo Transponder---7700 ATC---Notify
TAKEOFF WITH ENGINE FAILURE AT OR ABOVE V1
AFM4-01 p10
At Vr rotate the airplane according to the following: FLAP 1 - No Icing---ROTATE 9.5 DEGREES NOSE UP - Icing---Rotate 6 Degrees Nose Up FLAP 2 - No Icing---ROTATE 9 DEGREES NOSE UP - Icing---Rotate 5.5 Degrees Nose Up Positive Rate of Climb - LDG GEAR---UP - Airspeed--- V2
E 1 (2) FIRE (QRH EAP 6-3)
Affected Engine:
Thrust Lever—IDLE
START/STOP Knob—STOP
Shutoff Button—PUSH IN
If on ground or if fire persists after 30 seconds in flight;
Bottle Switch—DISCH
ELECT XFR FAIL (QRH EAP 4-7)
ELEC EMER Button—PUSH IN
INADVERTENT STICK PUSHER ACTIVATION ( QRH NAP 1-20)
QUICK DISCONNECT BUTTON—PRESS
PUSHER CUTOUT Button—PUSH IN
GEAR LEVER CANNOT BE MOVED UP (QRH NAP 1-18)
If associated with an engine failure and obstacle clearance simultaneously proceed:
DN LCK RELEASE Button—PRESS
LDG GEAR LEVER—UP
LG WOW SYS FAILS (QRH EAP 12-6)
If associated with an engine failure and obstacle clearance simultaneously proceed:
DN LCK RELEASE Button—PRESS
LDG GEAR LEVER—UP