Perform Wire Management Flashcards

1
Q

How far apart must conductors be supported?

A

every 18 inches, except off a batter bank, then 36 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What must you secure AC conductors with where they enter the vessel?

A

metal cushion clamps or conduit up to the first OCPD or fuse breaker

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

T/F - Conductors should not be secured to fuel lines

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When routing above machinery or when falling conductors could present a hazard, how should you secure them?

A

Use metal cushion conductors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where should you route conductors when near bilge water?

A

As high as possible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When routing conductors through bilge water, what precautions should you take?

A

Ensure connections are water-tight

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Can AC and DC primary wires be bundled together?

A

No, never

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Can conductors be routed above exhaust?

A

No, never

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How far should you route conductors from wet and dry exhaust?

A

9 inches from dry exhaust

2 inches from wet exhaust

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What should you use to protect conductors that may be exposed to physical damage?

A

Self-draining loom or conduit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What type of loom should you use?

A

Self-extinguishing, with a rating of UL V-2 or higher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What precautions should be taken when routing conductors near magnetically-sensitive equipment? (ie: compass or flux gate compass)

A

Install in a way as to prevent magnetic loops

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

T/F - Starter cables do not require overcurrent protection

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What consideration should be made for starter conductors?

A

Install the starter conductors above the normal accumulation of bilge water for their entire length.

Install starter conductors to avoid contact with any metallic fuel system or drive train components.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What should be done with AC connections as a safety precaution?

A

Enclose all AC connections to avoid electrocution.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When passing conductors, cables, and hoses through, over or around bulkheads, what precautions should be taken?

A

Protect from chafing using grommets, electrical tape, PVC pipe, or silicone adhesive.