Percentages Flashcards
NDE– RT film density of weld as compared to IQI’s (range)
-15 to +30%
Design - Mill tolerance of seamless pipe
-12.5%
Pipe class – percent of H2S in process to classify as class 1 pipe
Greater than or equal to 3%
NDE – percent of circuit welds to RT/UT when fabricating Norm service pipe
5%
NDE– percentage of welds to VT when fabricating normal service pipe
5%
Materials – maximum amount of chrome to be considered low-alloy steel
9%
NDE – overlap with a UT scan, % of transducer diameter
10%
AI – amount of time inspector must be involved in inspection activities – required to maintain API 570 certification 
20%
Materials – amount of Nickel for a material to be a nickel alloy
Greater than 30%
NDE - % Of visual and RT/UT required when fabricating severe cycle pipe
100%
Testing – minimum pneumatic test pressure, % of design pressure
110%
Testing – minimum test pressure for underground pipe, % of maximum operating pressure. Test In lieu of digging 
110%
PRV – maximum set pressure for thermal relief valve, % of design pressure
120%