PDA Standard of Practice Flashcards

1
Q

What is the Required Ram weight to mobilize test load

A

Ram must be 0.8% to 2% of Test Load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ASTM Standard Number for High Strain Dynamic Testing

A

D4945

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ASTM Standard Number for Energy Measurment

A

D4635

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

ASTM Standard Number for Low Strain Integrity Testing

A

D5882

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

ASTM Standard Number for Crosshole Sonic Testing

A

D6760

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

WSDOT Definition for Refusal

A

Refusal= 15 BPI for 4 consecutive inches of Driving

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the typical minimum splice length for steel Piles

A

10 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

WSDOT Minimum impact drive distance after vibratory installation

A

2 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly