PD 9514 - SAFETY MEASURES TABLE Flashcards

DIMENSIONS LANG

1
Q

**STAIRS
Maximum stair rise height for a class A stair

A

0.19 mtr.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

**STAIRS
Maximum height between landings for class A stair.

A

2.75 mts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

**STAIRS
Minimum headroom for class A & B stairs

A

2.00 mts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

**STAIRS
Minimum number of risers in any one (1) flight of stairs

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

**STAIRS
Minimum dimension of landings in direction of travel for class A & B stairs

A

112 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

**STAIRS
Maximum height of a handrail

A

86.5 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

**STAIRS
Minimum height of a handrail above the upper surface of the tread.

A

76 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

**STAIRS
Minimum clearance of a handrail from any wall.

A

38 mm.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

**STAIRS
Minimum height of a guard rail.

A

91 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

**STAIRS
Maximum height of a guard rail.

A

106 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

**STAIRS
Minimum inner radius of a monumental stair.

A

7.50 mts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

**STAIRS
Minimum width of a fire escape stair for existing stairs.

A

55.9 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

**STAIRS
Minimum width of landing for a fire escape stair for existing stairs.

A

55.9 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

**STAIRS
Minimum tread for a fire escape stair for small buildings.

A

15.25 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

**STAIRS
Maximum rise of fire escape stair for a small building

A

30.5 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

**STAIRS
Maximum rise of fire escape stair for existing stairs

A

22.9 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

**STAIRS
Maximum height between landings for a fire escape stair for existing stairs

A

3.66 mts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

**STAIRS
Minimum headroom clearance for a fire escape stair for existing stairs

A

2.13 mts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

**STAIRS
Standard inner radius of a curved stair in business occupancies

A

763 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

**STAIRS
Minimum headroom clearance for a fire escape stair for small buildings

A

1.98 mts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

**STAIRS
Maximum height of riser for Class ‘A’ stairs.

A

19 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

**STAIRS
Maximum height of riser for Class ‘B’ Stairs.

A

20 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

**STAIRS
Minimum width of stair for Class ‘B’ stairs serving more than 50 persons.

A

112 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

**STAIRS
Minimum width of stair for Class ‘B’ stairs serving 50 persons and below.

A

91 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

**STAIRS
Maximum horizontal projection of a handrail over a stair

A

38 mm.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

**STAIRS
Minimum width of a stair width for Class ‘A’ stairs

A

25 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

**STAIRS
Maximum height between landings for
Class ‘B’ stairs.

A

3.70 mts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

**STAIRS
Minimum width of landings in direction of travel for Class ‘A / B’ stairs.

A

112 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

**STAIRS
Minimum width for fire escape for existing stairs.

A

55.9 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

**STAIRS
Minimum horizontal dimension of any landing of platform for existing stairs for fire escape.

A

55.9 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

**STAIRS
Maximum rise for a fire escape for very small buildings

A

30.5 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

**STAIRS
Maximum height between landings for fire escape for existing stairs.

A

3.66 mts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

**STAIRS
Minimum tread for a fire escape stair for existing stairs

A

22.9 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

**STAIRS
Maximum reduction in width of a stair by a handrail

A

9 CM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

**STAIRS
Minimum stair width for a class B stair serving an occupant load of less than 50

A

91 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

**STAIRS
Length of a nosing or effective projection over the level immediately below it for tread below 25 cms in dimension

A

25 mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

**STAIRS
Maximum rise of any floor from the balcony floor to which an access door leads.

A

20.3 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

**RAMPS
Minimum width of a class A ramp

A

112 cms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

**RAMPS
Minimum width of Class ‘B’ ramp.

A

76 cms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

**RAMPS
Standard slope of Class ‘B’ ramp in percentage

A

10-17%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

**RAMPS
Maximum height between landings for Class ‘A’ ramp.

A

NO LIMIT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

**RAMPS
Maximum height between landings for Class ‘B’ ramp.

A

3.66 mts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

**RAMPS
Minimum width of ramps of 3 stories or more in height

A

1.20 mts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

**RAMPS
Minimum width of corridors, aisles, and ramps for exits in hospitals and nursing homes.

A

2.44 mts.

44
Q

**RAMPS
Minimum width of corridors, aisles, and ramps for exits in residential-custodial care.

A

1.83 mts

45
Q

**TRAVEL DISTANCE
Travel distance to an exit without fire sprinkler system.

A

46.00 mts.

46
Q

**TRAVEL DISTANCE
Travel distance to an exit with fire sprinkler system.

A

61.00 mts.

47
Q

**TRAVEL DISTANCE
Maximum travel distance between room door intended as exit access and exit with sprinkler system for institutional use.

A

30 mts.

48
Q

**TRAVEL DISTANCE
Maximum travel distance from the door of any room to exit for hotels with sprinkler.

A

30 mts.

49
Q

**TRAVEL DISTANCE
Maximum travel distance from the main entrance door to exit for apartments with sprinkler.

A

31 mts.

50
Q

**TRAVEL DISTANCE
Minimum distance travel to an exit for storage occupancies of high hazard commodities.

A

23 mts

51
Q

**TRAVEL DISTANCE
Minimum travel distance from any individual room subject to occupancy by not more 6 persons

A

15.00 mts.

52
Q

**TRAVEL DISTANCE
Maximum distance of travel from the high hazard area to an exit.

A

23.00 mts.

53
Q

**TRAVEL DISTANCE
Classified as mercantile occupancies, the travel distance from exits shall be

A

30.50 mts

54
Q

**TRAVEL DISTANCE
Minimum distance of an incinerator containing kindled fire or rubbish fire or bonfires.

A

5.00 mts

55
Q

**OCCUPANT LOADS, EXITS, AISLE
Unit area per person for waiting areas or standing rooms.

A

0.28 sqm.

56
Q

**OCCUPANT LOADS, EXITS, AISLE
Number of exits for place of assembly for 1000 occupants

A

4

57
Q

**OCCUPANT LOADS, EXITS, AISLE
Minimum width of an aisle serving an occupant of 60.

A

91 cms

58
Q

**OCCUPANT LOADS, EXITS, AISLE
Number of exits for place of assembly for 600-1000 occupants.

A

3

59
Q

**OCCUPANT LOADS, EXITS, AISLE
Maximum occupant load for a class C public assembly

A

50-300

60
Q

**OCCUPANT LOADS, EXITS, AISLE
Minimum number of exit for an Institutional type of structure.

A

2

61
Q

**OCCUPANT LOADS, EXITS, AISLE
Minimum width of an aisle serving an occupant of 60 or more serving one side for a public assembly building

A

91 cms.

62
Q

**OCCUPANT LOADS, EXITS, AISLE
Minimum width of an aisle serving an occupant of 60 or more serving two sides for a public assembly building

A

1.00 mtr.

63
Q

**OCCUPANT LOADS, EXITS, AISLE
Minimum width of an aisle serving an occupant of below 60 for a public assembly building.

A

76 cms

64
Q

**OCCUPANT LOADS, EXITS, AISLE
Occupant load per person for classrooms.

A

1.8 sqm

65
Q

**OCCUPANT LOADS, EXITS, AISLE
Maximum slope for aisles for public assembly structures.

A

(1:8) 12.5%

66
Q

**OCCUPANT LOADS, EXITS, AISLE
Any room for sleeping in institutional occupancies if subdivided shall have a maximum area of how many square meters?

A

465 sqm.

67
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle serving an occupant of 60.

A

91 cms

68
Q

**CORRIDORS, AISLES WIDTHS
Minimum increase in width for an aisle per linear meter.

A

2.5 cms

69
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle serving an occupant of 60 or more serving one side for a Public assembly building

A

91 cms.

70
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle serving an occupant of 60 or more serving two sides for a public assembly building

A

1.00 mtr

71
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle serving an occupant of below 60 for a public assembly building.

A

76 cms

72
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle for an educational use building.

A

1.80 mts

73
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle for hospitals or nursing homes.

A

2.44 mts

74
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle for custodial care institutions.

A

1.83 mts.

75
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle for business use structure.

A

112 cms

76
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle for an industrial building.

A

112 cms

77
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of any balcony or bridge.

A

112 cms.

78
Q

**CORRIDORS, AISLES WIDTHS
Minimum width of an aisle in a store for mercantile occupancies.

A

71 cms

79
Q

**CORRIDORS, AISLES WIDTHS
Minimum number of aisles for Class ‘A’ stores

A

1

80
Q

**CORRIDORS, AISLES WIDTHS
Minimum clear width of aisles for a Class ‘A’ store.

A

1.50 mts.

81
Q

**CORRIDORS, AISLES WIDTHS
Minimum clear width of an exit access through a covered mall.

A

3.66 mts

82
Q

**CORRIDORS, AISLES WIDTHS
Where exterior corridors or balconies are provided as means of exit, they shall open to the outside and shall be spaced ___ meters apart. (Educational)

A

76.25 mts.

83
Q

**DOORS EXITS
Minimum exit door width.

A

0.71 mtr.

84
Q

**DOORS EXITS
Minimum door width of a single door in a door way.

A

71 cms.

85
Q

**DOORS EXITS
Maximum change in elevation between the interior of a door to the outside of it other than a balcony.

A

20.5 cms.

86
Q

**DOORS EXITS
Maximum force in kilograms required for a panic hardware.

A

7 kgs.

87
Q

**DOORS EXITS
Maximum height required for a panic hardware installation.

A

112 cms.

88
Q

**DOORS EXITS
Width of devices such as bars or panel over doors width.

A

2/3

89
Q

**DOORS EXITS
Minimum height required for a panic hardware installation.

A

76 cms

90
Q

**DOORS EXITS
Maximum number of occupant for a subdivided room or space by a folding partition.

A

20

91
Q

**DOORS EXITS
Minimum width of a door for family day care homes.

A

61 cms

92
Q

**DOORS EXITS
Door openings means of egress.

A

71cm. - 122cm.

93
Q

**DOORS EXITS
Door swings on aisles, corridors, passageway or landings at least.

A

1/2

94
Q

**DOORS EXITS
Door projection over width of aisle, corridor, passageway or landing shall not be more than

A

178mm

95
Q

**DOORS EXITS
Revolving doors capacity of occupants exit.

A

50%

96
Q

**DOORS EXITS
Elevation of the floor surfaces on both sides of the door vary not more than in HT.

A

1.3cm

97
Q

**DOORS EXITS
Threshold on doorways shall not exceed.

A

1.3cm.

98
Q

**SEATING
Minimum spacing of rows of seats from back to back for a public assembly building.

A

0.83 mtr.

99
Q

**SEATING
Maximum number of seats in a row in between aisles.

A

14

100
Q

**SEATING
Maximum number of seats in a row opening on to an aisle at one side.

A

7

101
Q

**SEATING
Standard width of a seat without dividing arms for places of assembly.

A

60 cms

102
Q

**HEIGHTS, DISTANCE, WIDTHS
Minimum floor to ceiling height.

A

2.30 mts.

103
Q

**HEIGHTS, DISTANCE, WIDTHS
Minimum headroom created by any projection from the ceiling.

A

2.00 mts.

104
Q

**HEIGHTS, DISTANCE, WIDTHS
Buildings or structures 15 meters or more in height.

A

High Rise building

105
Q

**HEIGHTS, DISTANCE, WIDTHS
Minimum height of fence for a lumber yard for exterior storage of lumbers.

A

1.80 mts.

106
Q

**HEIGHTS, DISTANCE, WIDTHS
Minimum width of any driveway in and around a lumber yard / piles.

A

4.50 mts

107
Q

**HEIGHTS, DISTANCE, WIDTHS
Maximum width of sumps for the retention of oil and petroleum products.

A

3.70 mts.

108
Q

**HEIGHTS, DISTANCE, WIDTHS
Minimum height of buildings requiring automatic sprinkler protection.

A

15 mts