PD 1398 Flashcards

1
Q

“Size of water piping shall be based on the total _________

Water consumption

Water demand

Water potability

None of the above

A

Water demand

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Water closetbowls for________useshall beelongated bowl types equipped with open-front seats.

Public

Private

Government

None of the above

A

Public

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Wastewater drain for _________cupsink at church altar & baptisteries font outletshall discharge direct to the ground& not connected to any sanitary or drainage system.

Holy sink

Lavatory

Baptismal shrine

Sacrarium

A

Sacrarium

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Tunnelsshall have: the following except

A clear height of 0.6m above the pipe & shall be limited in length to 1/2 the depth of the trench.

Driven pipes shall have at least one pipe size larger than the pipe to be laid

Shall be back-filled in thin layers of 0.3m above the top of the pipe with clean earth which shall not contain stones, boulders, cinders or other materials which can damage or break the pipes or cause corrosive action.

None of the above

A

Shall be back-filled in thin layers of 0.3m above the top of the pipe with clean earth which shall not contain stones, boulders, cinders or other materials which can damage or break the pipes or cause corrosive action

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

the minimum cross sectional area at the seat of the control valve or the supply pipe or tubing which feeds the device outlet. If two or more lines supply one outlet, the effective opening shall be the sum of the cross-sectional areas of the individual supply lines or the area or the single outlet, whichever is smaller.

A. Effective opening

B. Effective depth

C. Effective area

D. Effective invert

A

A. Effective opening

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Suspended cast iron soil pipe shall be supported atnot more than ____m intervals,except that pipe exceeding 1.5m length may be supported atnot more than _____m intervals.Supports shall be adequate to maintain alignment & to prevent sagging & shall be placedwithin 0.45m of the hub or joint.

A. 1.5/ 3

B. 1.5/ 4

C. 3/ 1.5

D 4/ 1.5

A

A. 1.5/ 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

No water closet or bidet shall be setcloser than ______mfrom its center to any side of the wall or obstruction orcloser than ______m center to centerto any similar fixture.

A. .375 / 0.75

B. .375 / 0. 70

C. .40 / 0.70

D. .50 / 0.60

A

A. .375 / 0.75

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Lead Pipe - shall be supported atby____________for entire lengthwith hangers properly spaced.

A. Stiff aluminum or wooden backing

B. Stiff metal or wooden backing

C. Stiff plastic or metal sheet

A

B. Stiff metal or wooden backing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Fixtures havingconcealed slip jointconnections shall be provided with an access panel or utilityat least ______m in its least dimensionfor inspection & repair.

A. 0.30

B. 0.20

C. 0.10

D. 0.40

A

A. 0.30

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Excessive water pressure– water pressuregreater than ____ Kpa

A. 551

B. 552

C. 553

D. 554

A

A. 551

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

drains shall have a waterway equivalent area of the“tailpiece” –meaning, the sum of all the areas of the perforation of the strainer is equivalent to the outlet area.

A. Strainers serving bathub

B. Strainers serving shower

C. Strainers serving lavatory

D. None of the above

A

B. Strainers serving shower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Copper Tubing - shall be supported atapproximately ________m intervalsfor piping 38mm diameter & smaller & _______m intervalsfor piping 51mm & larger in dia.

A. 1.8/ 3.0

B. 1.9/ 3.5

C. 1.5 / 2.5

D. None of the above

A

A. 1.8/ 3.0

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Continuous waste fixture tailpiece connectionswere exposed or accessible may be of seamless drawn brassnot less than Ga. 20 B&S or ______mm thk.

A. 0.90

B. 0.80

C. 0.70

D. 0.60

A

B. 0.80

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Allporcelain enamel surfaceson plumbing fixtures shall be __________

A. Mold resistant

B. Acid resistant

C. Corrosion resistant

D. None of the above

A

B. Acid resistant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

All pipe determinations shall be based on eighty percent(___) the reduced pressure.

A. 70%

B. 60%

C. 80%

D. 90%

A

C. 80%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Incorrect Incorrect
______________ must be supported at least every other joint except that when the developed length between supports exceeds 1.2m, they shall be provided at each joint.

A. Couplings and compression joints

B. Hubless or compression gasket joints

C. Caps and plugs

D. None of the above

A

B. Hubless or compression gasket joints

17
Q

____________ - shall be supported by stiff metal or wood backing with hangers in its entire length for small-size tubings up to 38mm diameter & without backings but with spaced metal hangers at approved spacing for larger-size tubings.

A. Steel tube

B. Plastic tube

C. Aluminum tube

D. Concrete tube

A

B. Plastic tube

18
Q

If water closets or other plumbing fixtures are installed in the buildings where there is no sewer within a reasonable distance, suitable provision shall be made for disposing of the building sewage by some accepted method of sewage treatment and disposal, such as ______________

A. WASTE TANK

B. SEPTIC TANK

C. SEWAGE DISPOSAL SYSTEM

D. NONE OF THE ABOVE

A

B. SEPTIC TANK

19
Q

Drainage pipes shall be run in practical alignments & at a uniform slope between manholes of not less than ______________ toward the point of disposal.

A. 20mm/m or 2%
B. 30mm/m or 3%
C. 40mm/m or 4 %
D. 10mm/m or 1 %

A

A. 20mm/m or 2%

20
Q

Changes in direction of piping shall be made by the use of approved pipe fittings & shall be the angles presented by the following except

A. 22 ½ degrees bend

B. 45 degrees bend

C.60 degrees bend or other approved fittings of longer sweeps

D. 30 degress bend

A

D. 30 degress bend