Max depth of a septic tank in meters.
___________
▌#FTRSPDI , #FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
1.8m
A waste of holy water and wash water at church altar services must not be discharged into the sanitary drainage system but disposed of directly into the ground.
a. indirect waste
b. sacrarium
c. toxic waste
d. acid waste
▌#FTRSPDI , #FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
B.
An underground tank reservoir to store water.
a. Sump pit
b. Cistern
c. Water Tank
d. Aquifer
(study the differences between the choices^, including their functions)
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
Cistern
According to Principle No. 11, what is the primary purpose of designing the drainage piping system with adequate air circulation?
a. To avoid siphonage, aspiration, or forcing of trap seals
b. To prevent backflow contamination
c. To ensure proper water flow
d. To reduce noise in the drainage system
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
a. To avoid siphonage, aspiration, or forcing of trap seals
Advance notice for Testing and Inspection
______ days
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
3 days
The MAXIMUM VERTICAL DEPTH of liquid that a trap will RETAIN measured between the CROWN WEIR and the TOP OF THE DIP of the trap.
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
Trap Seal
On ___________, the First Amendment to the National Plumbing Code was approved, which effected the inclusion of “Asbestos·Cement Pipe” as an approved plumbing material.
a. November 28, 1967
b. November 28, 1968
c. November 28, 1969
d. November 28, 1970
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
A
1 FU = _____ cu.ft/min
practice conversions
▌#FTRPlumbingCode , #FTRSPDI
▌Start reviewing all the Secondary References we’ve recommended.
1 cubic ft/min
28.3 L/min
Min distance of Water Supply wells from Seepage Pit/ Cesspool
no choices
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
45.7 m
The maximum distance between manholes shall not exceed ___ meters.
a. 15m
b. 9m
c. 100m
d. 91m
▌#FTRPlumbingCode , #FTRSPDI
▌Start reviewing all the Secondary References we’ve recommended.
91m
Accessibility Law
__________
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
BP 344
Height of CRITICAL LEVEL ABOVE THE OVERFLOW RIM of the water closet or the highest part of a urinal.
_________
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
152mm or 6inch
According to Principle No. 17, what should be done if water closets or plumbing fixtures are installed in areas without a nearby sewer system?
a. A temporary storage tank should be installed
b. A connection should be made to a nearby building’s sewage system
c. Suitable sewage treatment and disposal methods, such as a septic tank, should be used
d. The fixtures should not be installed at all
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
C.
Any arrangement whereby reverse flow can occur.
no choices
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
Backflow connection
Min slope for shower receptor in % ____
Max slope for shower receptor in % ____
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
Min. 2%, Max. 4%
Sometime in _____, the PLUMBING TRADE was duly recognized by the government.
Date when former Pres. Estrada approved the 1999 RNPCP
___________
▌#FTRPlumbingCode
▌Start reviewing all the Secondary References we’ve recommended.
1902, December 21, 1999
***Minimum pipe sizing for a branch serving a 400 DFU.
a. 127 mm
b. 102 mm
c. 152 mm
d. 203 mm
▌#FTRPlumbingCode , #FTRSPDI
▌Start reviewing all the Secondary References we’ve recommended.
^up 🙂 Study Table 7-5
It is considered to be a SECONDARY PIPELINE.
a. Branch
b. Fixture Branch
c. Fixture Drain
d. Lateral
▌#FTRPlumbingCode
▌Start strong! Take notes of the Primary References.
Lateral
Aside from the number of fixtures connected, the size of the vent piping is determined by its
a. length
b. slope
c. change in direction
d. orientation
(see Table 7-5)
▌#FTRSPDI , #FTRPlumbingCode
▌Start strong! Take notes of the Primary References.
A. Length
What is the distance between the faucet and the flood-level rim of the basin into which it discharges?
▌#FTRPlumbingCode
▌Start strong! Take notes of the Primary References.
25.4 mm or 1 inch (AIR GAP!)
The Plumbing Code is used to:
a. Enforce the law
b. Confuse the plumber
c. Explain why plumbing installations may vary
d. explain why minor changes from the basic rules are acceptable
▌#FTRPlumbingCode
▌Start strong! Take notes of the Primary References.
A
The water in the trap between the dip and the crown weir.
a. Seal
b. Upper Dip
c. Critical Level
d. Air Break
▌#FTRPlumbingCode
▌Start strong! Take notes of the Primary References.
A. Seal
A vent that DOES NOT CARRY WATER or WATER-BORNE wastes.
_____________
▌#FTRPlumbingCode
▌Start strong! Take notes of the Primary References.
Dry vent
In sewerage, a COMMON SEWER to which NO OTHER BRANCH SEWER is connected.
a. Branch
b. Building Drain
c. Lateral
d. House Sewer
▌#FTRPlumbingCode
▌Start strong! Take notes of the Primary References.
Lateral