P-8A Flashcards
When the OIL QUANTITY REPORT page shows ADD for the oil level, what action should be taken?
Initiate MAF.
The APU operator licensing program shall be managed by QA and administered by the NATOPS officer.
False
The Command Officer may delegate the authority to sign APU authorizations as low as department heads.
False
The APU continues to operate for approximately 60 seconds during it’s cool down cycle.
True.
One of the indications of an APU fire is the APU fire switch is illuminated.
True.
How many indications are there for APU fire?
More than 6.
If extended APU operation or prior to engine start, which fuel boost pump should be turned on?
Left center, if center tank quantity is over 1000 pounds.
The APU can be started or shutdown during refueling operations.
True.
If the APU DET INOP light fails to illuminate DO NOT OPERATE THE APU.
True.
The APU fire detection system is powered by the hot battery bus.
False.
The Center tank fuel pump switches should be positioned to ON only if the fuel quantity in the center tank exceeds 1000 pounds.
True.
An APU maintenance problem exists when what light is illuminated?
BLUE MAINT LIGHT.
During APU operation, fuel is automatically heated to prevent icing.
False
Rotating the APU fire switch in either direction mechanically fires the squib, discharging the extinguishing agent into the APU.
True.
If the start fails or the APU RUNNING light fails to illuminate by the end of the start cycle, what has just occurred?
A system failure has occurred and the fault light illuminates.
A DC operated boost pump is installed to ensure positive fuel pressure…
… To the APU fuel control during start and operation and automatically when the APU fuel control unit senses low fuel pressure.
Air for the APU cooling comes from where?
Air inlet.
The MO must recommend an unqualified individual prior to commencement of APU turn-up training.
True.
The first step of the emergency procedures of an APU fire is to pull and rotate the APU fire switch to the top for one second.
True.
If you get an illuminated over speed light, the light will remain illuminated for _______ when the APU switch is placed off.
5 minutes.
If the APU fire warning light is not illuminated, but a fire indication exists or a fire is reported in or near the APU?
Press the APU fire switch lock release button, pull the APU fire switch, rotate the APU fire switch to the top until APU bottle discharge light illuminates.