Flight crew oxygen is supplied by __________ located in the E&E compartment.
Single cylinder
The max servicing pressure for flight crew O2 bottle is?
1850 psi
When testing the oxygen mask, the appearance of a _____________ indicates oxygen flow on the oxygen flow indicator.
yellow cross
The passenger O2 system is activated automatically by a pressure switch if the cabin altitude reaches ________ or when the _______ switch is selected ON
14,000 feet; PASS OXYGEN
Once a passenger chemical O2 generator is activated, Oxygen flows continuously at 100 percent concentration for approximately ____________
12 minutes
Below _______ feet cabin altitude, do not initiate the use of passenger oxygen if smoke or fire is present.
14,000
What are you checking when checking the green oxygen indicator disc on the bottom right side of the fuselage?
The absence of the disc indicates a thermal discharge of the crew’s oxygen cylinder has occurred. Call mx to replace
T/F: The passenger oxygen system prevents the passengers from inhaling smoke if there was a fire.
False. For this reason, don’t deploy pass oxygen when smoke or fire is present below 14,000’