Oxygen Flashcards
The fight deck oxygen mask system consists of _______.
3 oxygen masks, and storage containers.
(Not in the flightdeck: crew oxygen cylinder, refill point)
Oxygen permits a decent from 41,000 ft. to 10,000 ft. for up to 22 minutes and then a continuation at 10,000 ft. for _______ minutes.
98 minutes
(from 41,000 ft. to 10,000 ft. in 22 minutes with mask regulator at 100% mode and continuing cruise at 10,000 ft for 98 minutes with mask regulator on NORM mode. 14.5 Vol 2)
The oxygen mask regulator has _______ positions.
3
[normal, 100%, emergency]
The oxygen pressure is continuously monitored and is displayed on the _______.
Status page of the MFD
_______ dashes indicate invalid crew oxygen information or a value out of the
valid range.
amber
In order to reset the oxygen mask and communications back to normal after the oxygen masks have been removed, pilots must accomplish which of the following?
Close the stowage box doors and press Reset Button
What produces oxygen for passengers if pressurization is lost?
Individual chemical oxygen generators
True or False: A PAX OXY NOT DEPLOYED caution message will display on the
EICAS if the masks did not deploy after an automatic or manual command.
True
True or False: The passenger oxygen masks will only deploy if manually
commanded.
False
Passenger oxygen supplies _______ minutes of flow.
Approximately 12 min.
True or False: Oxygen is available in the lavatories in the event of a pressurization loss.
True
True or False: There is no way to determine crew oxygen pressure from the flight deck. It can only be done at the bottle.
False
True or False: The passenger oxygen masks provide smoke protection.
False
Each passenger overhead oxygen compartment is equipped with a storage door that is normally held closed by an electrical latching mechanism. This automatically releases when the cabin altitude reaches approximately _______.
14,000 ft
True or False: Each passenger overhead oxygen compartment is equipped with a storage door that is normally held closed by an electrical latching mechanism. This automatically releases when the cabin altitude reaches approximately 10,000 ft.
False
[14,000 ft]
Portable oxygen is located _______ for walk-around or portable use in the cabin.
Near each flight attendant station
The PBE can supply oxygen for approximately_______ minutes.
15 min.
True or False: The PBE does not protect against smoke.
False
True or False: Only the Captain’s and First Officer’s seat positions have a
microphone built into the oxygen mask.
False
(Also the jump seat)
True or False: If the passenger overhead oxygen compartment doors did not open automatically during a pressurization failure, there is no way for the pilots to manually deploy the masks.
False
When the crew fixed oxygen system is charged enough for three crewmembers, the oxygen pressure is displayed with which color?
green
Which color is the oxygen pressure displayed in when there is only sufficient
supply for two crew members?
cyan
Once activated, each chemical generator can provide approximately _______
minutes of oxygen.
12 min.
The NORMAL position on the crew oxygen mask accomplishes what?
The pure oxygen to ambient air mixture ratio is dependent on cabin altitude