OT 3 Flashcards

1
Q

In order to justify an automatic processor, 20-25 14”x17” films should be run through how ofter?

A

Each week.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If your temperature is too high in the dryer part of your automatic processor, what will most likely happen?

A

The films will probably have water spots.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

With manual processing after a film is first put into solution, what is the next recommended step?

A

Agitate it.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where would you place the wire mesh for a wire mesh test?

A

On the cassette.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which of the following is NOT one of the criteria for holding a patient?

a. never use pregnant female to hold patient
b. the holder should wear protective apron and gloves
c. only employees should hold patient
d. the holder should be over 18 years old

A

c. only employees should hold patient.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the occupational annual dose limit for whole body exposure?

A

5 rem

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Let’s say you have just installed an automatic processor in your dark room. Since is is a big processor you actually want it to be out of your small darkroom, Which part of the processor MUST be in the darkroom?

A

the feed tray.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

1/16” lead is equivalent to how many inches of concrete?

A

Four.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which combination of screen light and film color is preferred?

A

Green light and purple film.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How will dirt on the intensifying screen appear on the exposed film?

A

White specks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which of the following would lead to the least exposure of a patient to ionizing radiation?

a. a grid
b. an extremity cassette
c. a dual screen system
d. an underpart filter

A

c. a dual screen system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What effect will a too fast of film-screen combination have on the radiograph?

A

It will demonstrate graininess.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Which speed is preferred in general spinal radiography with rare earth system?

A

400

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Having a thicker phosphor layer in your screens will do what to the screens?

A

make the screen faster.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Your x-ray service person has told you that he has just completed a “wire mesh” test. In order to say something intelligent you have to think back to what the test is for. So, tell me! What does it test anyway?

A

if there is good contact between the screens and film.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Why should bad films that you have taken not be destroyed?

A

They can be sold for silver.

17
Q

About how many 14”x17” films should be run through an automatic processor in a week before it is economically feasible?

A

20-25

18
Q

Sensitometry is a way to do what?

A

Check consistency of processing.

19
Q

When using the four basic densities or x-ray interpretation, which of the following is the second least dense?

A

Oil.

order=
metal, water, oil, air.

20
Q

In inches, what is the lead equivalent thickness required for a ceiling of a single story building?

A

None.

21
Q

If your patient has a very large gut, what would you use to get a good full spine series?

A

A dual screen cassette with a grid.