Ops Limits Flashcards
1
Q
Start
A
EGT: 925 (Max) 845
Fuel Flow: 360 lb/hr
Oil > 0 psi
EGT rise w/in 12” of introduction of FF
2
Q
Load Factor
3500
A
-2.3 to 5.7 0 to 4.1
3
Q
Load Factor
3000
A
-2.4 to 5.9 0 to 4.3
4
Q
Load Factor
2000
A
-2.6 to 6.5 0 to 4.7
5
Q
Load Factor
1000
A
-2.9 to 7.2 0 to 5.0
6
Q
Prohibited Maneuvers
A
Vertical Stalls
Intentional Spins
Continuous Aileron Rolls at other than 1.0G and/or greater than 3/4 stick deflection
7
Q
WSSP Limitations
Load Factor
A
0 to 4.0G 0 to 3.0G
8
Q
WSSP Limitations
Airspeed
A
Max 400 KCAS
SB Open/ Turb 350 KCAS
Abrupt Control 240 KCAS