What is the output in kv?
7.5 kv
What is the onan used for?
Powers the 110 volt lighting, electrical outlets, and a battery charger for apparatus
How many amps?
31 amp
How many hz does onan run at?
60hz
What RPM does the onan run at?
1800rpm
Where is The access to generator?
On top and right compartment
Where are the quartz light controlled from?
Inside switches in left compartment, cab dash, and lights themselves
What rig have the 200 ft cord reel?
95/96, 03-09
What rigs have the 250ft cord reel?
2000-2002
How many amp receptacles are on the junction box?
20 amp
How many circuit breakers are there?
12 breakers
How many outlet receptacles?
7 total- 2- tractor 2- trailer 2- cord reel 1- end of aerial
What is the cause of a circuit breaker trip?
Either a short or too much load
What Can a no load operation cause?
Create unburied fuel and “slobbering and white smoke”
When shutting down how long to run with no-load before complete shut down?
3-5 minutes
What year encompassed the generator logic control with auto start stop?
2006
When does the auto start turn on generator?
When voltage in batteries drop to 12.1volts and below and will run until 13.3 volts for 1 continuous hour.
How to set a time for auto run?
Set by pressing corresponding button for 3 seconds. Generator will attempt to crank and start for 5 seconds then stop for 5 seconds and will retry 5 times at which will show a “Gen Fail” message. To clear press the start/ stop button.
What happens if activity timer starts and gen has ran for 24 hr with no activity?
Generator with auto shutoff
What is the operating temp range?
160-195
What is the oil pressure range on onan?
28-64 psi