The largest drop in temperature in an ACM occurs as the air passes through the _____________
expansion tube
Match the vapour cycle system components to their definitions. -Meters out low pressure, low temperature liquid refrigerant. 1.Compressor 2.Condensor 3.Receiver Dryer 4.Thermal Expansion Valve 5.Evaporator
thermal expansion valve
Pressurized aircraft can use cabin ventilation systems
Only when unpressurized
What three instruments are commonly found in large aircraft to monitor the pressurization system?
cabin vsi cabin altimeter cabin differential pressure
Large aircraft outflow valves are controlled by
AC and DC electric motors
Hydrostatic testing is used on
High pressure oxigen bottles
What two heater components are inspected in AD 2004-21-05?
-combustion liner -combustion air pressure switch
the pressure relief valve on the______(50 %)(outflow/safety) valve is set slightly higher than the______(50 %)(outflow/safety) valve
safety, outflow
What is the difference between a shroud style heater and an intensifier tube?
An intensifier tube is mounted inside the exhaust pipe and the shroud is outside the exhaust pipe
The heat required for a liquid to be transformed a vapour is called
latent heat of evaporation
Pilot controlled thermostatic switch
Duct Switch
Normally open thermostatic switch
Purge switch
Used by pilot to latch K-10 relay
Heater Start Switch
on our small to medium sized aircraft pressurization systems, the _____________ valve does most of the work on a normal pressurized flight
outflow
__________________ is caused when there’s not enough pressure to allow the oxygen to be absorbed into the blood.
anoxia
Set at 0.2 psi
Combustion air pressure switch
Overall system safety switch
Overheat Switch
On our small to medium sized aircraft pressurization systems, the outflow valve performs how many functions?
Three
Turns on combustion blower
Off/Vent/Heat Switch
All refrigerant must be converted to a ____________ before entering the compressor
vapour
When the set temperature is reached, K-10 is unlatched
Overheat Switch
All aircraft must be operated with a cabin altitude less than 8000’ True or False
false
Match the vapour cycle system components to their definitions. -Refrigerant enters as high pressure, high temperature vapour and leaves as high pressure, high temperature liquid 1.Compressor 2.Condensor 3.Receiver Dryer 4.Thermal Expansion Valve 5.Evaporator
condensor
What will cause the Heater Fault Light to illuminate?
The Combustion Air Pressure Switch opening
Acts as backup to duct switch
Cycle Switch
Which of the following is not used to provide air to the ACM? 1.APU bleed air 2.Main engine bleed air 3.Ground cart 4.Ram air
Ram air
AD CF90-03R2 requires that a leak test be performed on all exhaust type heaters every year or 150 hours true or false
false