An inspector enters a vacant home to inspect it and notices a strong smell of gas.what should he do?
Vacate The home and call all appropriate people
What was added to furnaces in 1980 to increase efficiency:
Two heat exchangers
What material is not a proper flashing material : A.copper B.galvanized C.aluminum D.tar paper
D.tar paper
A three prong receptacle requires
Grounding conductor
The neutral wire:
Returns 110v to ground
Ice forming on the A/C evaporator coil is caused by:
Not enough air
The exhaust vent of a gas dryer:
Must be vented to the outside
Deck built 14” off ground around a home
Requires no railing
In an electrical sub panel,the neutral wire must be
Both separated from ground and isolated
Trusses :
Have two bearing points
You see a return air register in the side of a furnace:
Can cause flue gases to be drawn into supply air.
Mid-efficiency furnace
No draft diverter required
What is the proper exposure for a 24” Shake
10”
Safety glazing is not required in:
Greater than 10 sqft over 18” above floor
Stucco hairline cracks appear every 16”. The cause can be attributed to:
Nailing drywall on inside
On a tile roof what is the proper way to flash around the chimney
Counter and pan flashing
You are inspecting a home built in 1950 and see a silver wire to a branch circuit. This would be:
Tin coated copper
Moisture accumulates in poorly vented attic because
Warm air rises and condenses in the attic
What is the proper exposure for an 18” wood shake
7 1/2”
You view a type “B” vent in an attic. Insulation is falling in the open chase.what do you report
A. What you see
B.recommend a fire stop be installed
C.recommend they remove insulation from chase
D. All The above
D. All the above
What determines the size of flue
Opening of fire place
Metal chimney cap function does not include: A. Keeping animals out B. Keeping out rain C. Keeping debris out D. Reducing draw of exhaust gases
D. Reducing draw of exhaust gasses
Cross bridging on floor joists:
Keeps joists from twisting
Potential problems with roof sheathing is: A. 3/8" plywood used B. Ends touching each other C. Plywood placed parallel to rafters D. All the above
D. All the above
Which of the following does not require a dedicated circuit: A. Kitchen counter B. Bathroom C. Dining room D. Central heating
C. Dining room
Wood shakes are most likely to wear And expose felt paper at:
Key way
How far off the floor does a furnace’s source of ignition have to be in a garage:
18”
Flat roof is used as an observation deck. Plumbing vent must extend:
7 feet
An inspector is required to inspect at least :
One window in each room
A 12’ long 2x8 floor joist has a notch. Where would The notch not be ok:
In the middle
A properly constructed retaining wall should:
Be back filled with gravel
A horizontal crack In a brick wall follows the gutter line. What is the cause:
Rafter spread
In EIFS construction doors and windows can properly sealed by:
Backer rod and sealant
A gas water heater is not allowed in:
Storage closet
Each zone valve for a hydronic heating unit needs:
Thermostat
Sumo pump runs even though is has been dry( no rain) for a long time. What is the cause
Float stuck
How much space is required between a double walled “B” vent and chase:
1”
A new electric dryer receptacle A. May have 4 wires to it B. Just be a dedicated circuit C. May be 120 volts D. All above
D. All above
If the exterior service piping has been converted to plastic, what is required for electrical grounding:
Provide another grounding means
The maximum number of disconnects to shut off an electrical service is:
6
Which of the following is not an acceptable grounding means :
Underground gas pipe
An electrical panel with a split busbar:
Has more than one shut off
What insulation is/was considered a safety hazard:
UFFI
Reverse polarity is:
Possible to cause a shock hazard
Which of the following would be the least hazardous for a staircase:
1/4” riser differential
Romex wiring can be used: A. Outside B. In garage with proper height C. In attic nailed to top of joist D. All the above
D. All the above
Another name for Romex is:
NM
Do you consider a missing remote control a defect on a garage door opener?
No
Central air added to an existing furnace. What is required?
2 speed fan
A 50 year old, forced air heating system has been retrofitted with an evaporator coil as part of a split system air conditioner. The ducts are original steel with 4” branch ducts insulated with asbestos paper. What can happen ?
The duct system may be prone to rusting and probably undersized for air conditioning loads.
A gas appliance vents through a 5/12 pitched roof requires a minimum clearance of :
1 foot
What is the proper clearance above a stovetop for a cabinet:
30”
Garage door requirement for garages built before 1978:
Needs safety wire through spring coil
The proper pressure of a hydronic heating system:
12-15
Where is the circulating pump for a hydronic heating system normally located:
Return side
What is a characteristic of knob and tube wiring:
No ground
Siding with insulation board underneath, covers the service entry Wire on a house.you report:
Can not be covered by the siding
What is not a cause of horizontal cracking in a foundation wall:
Wet basement wall
What is not a source or sign of a wet basement
Crack in floor
What would you not list as a safety hazard upon examination a chimney
No damper
A fireplace with an opening less than 6’ needs to have the hearth extended ___” to front and ___” to side
16”
8”
A fireplace with opening over 6’ needs to have the hearth extend ___” to front and ____ “ to side
20”
12”