mo Flashcards

1
Q

radep:dev=RBLt2-43

A

!DEVICE DATA IN BSC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

RLDEP:CELL=ALL;

A

(get BCCH,BSIC, CGI, … for all cells in BSC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

dtble:dip=228rbl2;

A

baraye chek kardan link dar hengame ghati

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

dtqdp:dip=120rbl2;

A

(check the quality of E1) prints the historical quality data for the specified digital path.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

DTDIP:DIP=12RBL2

A

!DIGITAL PATH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

dtstp:dip=247rbl2

A

!DIGITAL PATH STATE(abl yani likn ghate,wo yani kar mikonad)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

dtqup:dip=165rbl2;

A

generates a printout containing the quality situation for the specified Digital Paths (DIP).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

DTSTP:DIP=187RBL2;

A

?

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Exit/Quit

A

(exit from the BSC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

rlapp:cell=T7800XA;

A

(AMR POWER CONTROL CELL DATA )

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

rlbcp:cell=T7800XA;

A

(DYNAMIC BTS POWER CONTROL CELL DATA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

RLBDP:CELL=ALL;

A

(get number of required BPC for each cell in BSC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

rlbdp:cell=t7655xa;

A

Print GPRS Status and configuration/NUMREQEGPRSBPC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

rlbdP:CELL=T8801xc;

A

To check Number of TRX

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

RLCCC:CELL=T8954XB,CHGR=0,SDCCH=4,CBCH=YES,TN=1&&4;

A

To add SDCCH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

rlccc:cell=E9961XC,CCCH=1,CHGR=0;

A

To add CCCH

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

RLCCP:CELL=ALL;

A

(get SDCCH number per cell)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

rlcfp:cell=e1516b;

A

!CELL CONFIGURATION FREQUENCY DATA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

RLCFE:CELL=T0872YB,CHGR=1,DCHNO=25&34&36;

A

To add TCH frequencies (2-for delete the previous frequencies)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

RLCFI:CELL=T0872YB,CHGR=1,DCHNO=24&26&33;

A

To add TCH frequencies (1-for add new frequencies)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

RLCFP:CELL=ALL;

A

(get Frequency list for all cells in BSC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

RLCHP:CELL=ALL;

A

(get HSN number and MAIO list per cell)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

rlchp:cell=T7800XA;

A

(CELL CONFIGURATION FREQUENCY HOPPING DATA)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

RLCPP:CELL=E163B

A

!CELL CONFIGURATION POWER DATA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

RLCPC:CELL=t8860xa,sctype=ul,bspwrt=42;

A

To reduce power if there is subcell

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

RLCPC:CELL=t9474xb,bspwrb=42,bspwrt=42;

A

To reduce power-If we don’t have subcell structure (OL & UL)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

RLCPP:CELL=ALL;

A

(get BSPWRB, BSPWRT, MSTXPWR per cell)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

RLCRP:CELL=ALL;

A

(get traffic & ICM Band per cell)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

rlcrp:cell=T8858XB;

A

baraye didane daghighe site ke kodomesh ghat shode agar faghat 900 bashe amalan 1800 ham nemitone terrafic begire chon bcch roye 900 hastesh/ Cell resources.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

rldgp:cell=T7800XA;

A

(CELL CHANNEL GROUP DATA )

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

RLDHC:CELL=T7800XA,DHA=ON,DTHAMR=35,DTHNAMR=20;

A

HR tuning.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

RLDHP:CELL=ALL;

A

(get DTHAMR, DTHNAMR per cell)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

rlgap:cell=T8135XA;

A

baraye check kardane odbchlimit ke bayad baraye gprs hatmana 100 bashad/ !CELL CHANNEL GROUP ALLOCATION DATA (ODPDCHLIMIT)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

RLGRP: CELL=T7800XA;

A

Print GPRS Status and configuration/ !CELL GENERAL PACKET RADIO SERVICE RESOURCES DATA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

RLGSP: CELL=T7655xc;

A

Print GPRS Status and configuration/ !CELL GENERAL PACKET RADIO SERVICE DAT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

RLHPC:CELL=T7800XB,CHAP=0;

A

To Change CHAP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

RLDMP:cell=t8177xa

A

!CELL DYNAMIC FR/HR MODE ADAPTATION DATA(DYMA)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

RLHPP:CELL=ALL;

A

(get CHAP for all cells in BSC)/ !CONNECTION OF CELL TO CHANNEL ALLOCATION PROFILE DATA (CHAP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

rlihp:cell=T7800XC;

A

(CELL LOCATING INTRACELL HANDOVER DATA)

40
Q

rlimp:cell=T7800XC;

A

(CELL IDLE CHANNEL MEASUREMENT DATA)

41
Q

RLLCC:cell=T8760XB,CLSLEVEL=40,CLSACC=60;

A

To change the CLS

42
Q

rlldp:cell=T7800XC;

A

!CELL LOCATING DISCONNECT DATA(MAXTA)

43
Q

rllhp:cell=T7800XC;

A

(CELL LOCATING HIERARCHICAL DATA)

44
Q

rlllp:cell=T7800XA;

A

(SUBCELL LOAD DISTRIBUTION DATA)

45
Q

RLLOP:CELL=E163B

A

!CELL LOCATING DATA (BSTXPOWER)

46
Q

RLLOC:CELL=T8860XA,BSPWR=43;

A

To change locating parameter after reducing power

47
Q

RLLOC:CELL=T8860XA,BSPWR=43,BSTXPWR=43,BSRXMIN=100;

A

To change locating parameter after reducing power-If we don’t have subcell structure (OL & UL)

48
Q

RLLOC:CELL=T8860XA,SCTYPE=UL,BSTXPWR=43,BSRXMIN=100;

A

To change locating parameter after reducing power

49
Q

RLLOP:CELL=All;

A

(get BSPWR, BTSXPWR per cell) MSRXMIN

50
Q

RLLPC:CELL=LIN1,PTIMHF=60;

A

To change PTIMHF

51
Q

rllup:cell=T7800XC;

A

!CELL LOCATING URGENCY DATA(TALIM)

52
Q

RLMFP:CELL=ALL;

A

!CELL MEASUREMENT FREQUENCIES

53
Q

rlmfp:cell=T9790XB;

A

baraye didane kolie frequency haye active va idle ke active ha male sector haye hamsaye hastesh

54
Q

RLNRC:CELL=T7800XA, CELLR=T7656XB, CS=NO, CAND=BOTH, AWOFFSET=3, BQOFFSET=3, BQOFFSETAFR=3, HIHYST=5, LOHYST=3, OFFSETP=0;

A

To change locating offset & hyst

55
Q

rlnrc:cell=t8853xc,cellr=t8661xb,offsetn=5

A

To change OFFSETN

56
Q

rlnre:cell=T8391XC,cellr=T8972XC;

A

To delete neighbor relation

57
Q

rlnri:cell=t9175xb,cellr=t9176xb,single;

A

to define one way neighbour

58
Q

RLNRP:CEll=T7800XA, CELLR=ALL;

A

(get all neighbors with their data)

59
Q

rlnrp:cell=t8391xb,cellr=all,nodata;

A

to check All Neighbors of One Cell

60
Q

Rlolp:cell=T7800XA;

A

!CELL LOCATING OVERLAID SUBCELL DAT/ To get LOL

61
Q

rlpcp:cell=T7800XC;

A

(DYNAMIC MS POWER CONTROL CELL DATA

62
Q

rlpcp:cell=

A

!power control(MS)

63
Q

rlbcp:cell=

A

!power control(BTS)

64
Q

rlapp:cell=

A

!power control(AMR)

65
Q

RLSBP:CELL=ALL;

A

!CELL SYSTEM INFORMATION BCCH DATA (get CRO per cell) parameters like MAXRET,CRO,PT,…

66
Q

rlssp:cell=T7800XA;

A

(CELL SYSTEM INFORMATION SACCH AND BCCH DATA )

67
Q

RLSSP:CELL=ALL;

A

(get CRH per cell)

68
Q

RLSTC:CELL=T8575XC,STATE=ACTIVE;

A

To activate a cell

69
Q

RLSTC:CELL=T8575XC,STATE=HALTED;

A

To halt a cell

70
Q

rlstp:cell=all,state=halted;

A

baraye didane kolie site haye halt dar yek bsc

71
Q

rltdp:msc=all

A

!MSC TRAFFIC DISTRIBUTION DATA

72
Q

rrplp:trapool=all

A

!RADIO TRANSMISSION TRANSCODER POOL SELF CONFIGURATION LOG

73
Q

rrpsp:trapool=all

A

!RADIO TRANSMISSION TRANSCODER POOL SELF CONFIGURATION DATA

74
Q

rrscp:scgr=505

A

!RADIO TRANSMISSION SUPER CHANNEL DATA (No of E1 dev for SCM Mode -numdev)

75
Q

rrtpp:trapool=all

A

!RADIO TRANSMISSION TRANSCODER POOL DETAILS(tr traffic)

76
Q

RLSTP:CELL=T9316XA;

A

To check if site is active or halted

77
Q

RXAPP:MO=RXOTG-52;

A

To chk EDGE , idle channels , get number of devices on E1 we used for site , 64k/ !RADIO X-CEIVER ADMINISTRATION (No of E1 dev for TDM Mode- NO OF 64K

78
Q

RXASP:MO=RXOTG-52;

A

(get list of alarms on Cell) !RADIO X-CEIVER ADMINISTRATION -MANAGED OBJECT ALARM SITUATIONS

79
Q

RXASP:MOTY=RXOTG;

A

List fo alarms in BSC

80
Q

RXBLE:MO=RXOTG-104,subord;

A

For SOFT RESET of a site

81
Q

RXBLI:MO=RXOTG-104,subord,FORCE;

A

For SOFT RESET of a site

82
Q

RXCDP:MO=RXOTG-52;

A

(get the config/ number of TRXs and their status) !RADIO X-CEIVER ADMINISTRATION -MANAGED OBJECT CONFIGURATION DATA /CONFIG-AVAILABILITY (TS-TX-RX)

83
Q

rxese:mo=rxotg-104,subord;

A

For SOFT RESET of a site

84
Q

rxesi:mo=rxotg-104,subord;

A

For SOFT RESET of a site

85
Q

rxmfp:mo=rxotrx-205-0

A

!RADIO X-CEIVER ADMINISTRATION-MANAGED OBJECT FAULT INFORMATION Alarm on TG-CF ,.. level

86
Q

rxmfp:mo=rxocf-18

A

!RADIO X-CEIVER ADMINISTRATION-MANAGED OBJECT FAULT INFORMATION

87
Q

RXMFP:MO=RXOTG

A

initiates printing of fault information for one or more managed object

88
Q

rxmop:mo=rxotg-52

A

CHK if VSAT ( SIGDEL=LONG )

89
Q

rxmop:mo=rxotrx-34-0&&-11

A

!RADIO X-CEIVER ADMINISTRATION-MANAGED OBJECT DATA(Seeing config of Site)

90
Q

rxmop:mo=rxotg-34

A

!RADIO X-CEIVER ADMINISTRATION -MANAGED OBJECT DATA (Details for specific TG)

91
Q

rxmop:mo=RXOTG-86

A

To check CONFACT

92
Q

rxmsp:MO=RXOCF-418;

A

To check if cell is manually blocked (BLSTATE: MBL) !RADIO X-CEIVER ADMINISTRATION-MANAGED OBJECT STATU

93
Q

RXTCP:CELL=ALL, MOTY=RXOTG;

A

(get each cell is connected to which TG)

94
Q

rxelp:mo=rxotg-1

A

!RADIO X-CEIVER ADMINISTRATION -ERROR LOG DATA

95
Q

rxmdp:mo=rxotrx-43-0&&-11

A

!RADIO X-CEIVER ADMINISTRATION -MANAGED OBJECT DEVICE INFORMATION

96
Q

stdep:dev=rblt2-1025&&-1055

A

!DEVICE STATE DETAILS (TRANSMISSION)