MK16 Specs Flashcards
What are the charing rates
100 psi dry
200 psi wet
When does the MK16 tranistion
Descent 33 fsw (+-2)
Ascent 13 fsw (+-2)
Normal Oxygen Sensors operating range
22-28 Millivolts (mV)
The MK 16 MOD 1 consist of what four systems
1 - Housing System
2 - Recirculation System
3 - Electronic System
4 - Pneumatic System
What is the depth Limits
N2O2 (79/21)
Normal Working Limit - 150
Max Working Limit - 190
Wha is the depth Limits
HeO2 (88/12)
Normal Working Limit - 300
Max Working Limit - 300
MK16 MOD 1 Line Pull
1 Pull
Arrived at the lazy shot
MK16 MOD 1 Line Pull
7 Pulls
I have started, found or completed work
MK16 MOD 1 Line Pull
2-3 Pulls
I have decompression symptoms
MK16 MOD 1 Line Pull
3-2 Pulls
Breathing from EBS
MK16 MOD 1 Line Pull
4-2 Pulls
Rig malfuntion
MK16 MOD 1 Line Pull
2-1 Pulls
Unshackled from the lazy shot
MK16 MOD 1 Line Pull
5 Pulls
I have exceeded the planned depth of the dive (followed by 1 pull for every 5 ft)
Signs and Symptoms of O2 Tox
V - Visual Symptoms
E - Ear/hearing Symptoms
N - Nausea
T - Tingling/Twitching
I - Irritability
D - Dizziness
C - Convultions
Minimum Equipment for MK 16 Dive
- MK16 MOD 1 UBA
- M48 Full Face Mask
- MK11 BC with inflation bottle
- Watch or DT/DG
- Depth gauge or DT/DG
- Weight
- Knife
- Thermal Protection
- Witness/Tending Line
- Buddy Line
Minimum Personnel Requirements for MK16
I Diver 4 personnel
2 Diver 5 Personnel
Sup/Diver(1 or 2)/ Standby / Tender
Permissible Dive for N2O2 1.3 ata
- Multiple repet up to 150 fsw in no D
- One D dive up to 150 fsw and three no D dives
- Repet dive 151 - 190 CNO waver
- Repet dive on air followed by MK16 on nitrogen (USNDM)
- Repet dive on MK16 on Nitrogen following Air dive (USNDM)