MK-16 Component Systems Flashcards

1
Q

What is the function of the housing system?

A

Maintains low-mu
Streamlines the rig
If lost, dive must be aborted.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the Recirculation system’s function?

A

Removes CO2 from exhaled breathing gasses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the support screens for?

A

Allow proper gas circulation between moisture absorbent pad and canister.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the function of the moisture absorbent pads?

A

Absorbs the moisture in the exhaled breathing gases.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the function of the hydrophobic filter?

A

Retards moisture and disperses gas for an even flow through absorbent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the purpose of the compression pad?

A

Evenly distributes pressure on absorbent.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the two types of CO2 absorbent?

A

High performance sodasorb (4-8 mesh)

Sofnolime (8-12 mesh and 4-8)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

True or false, The use of IND (indicating) CO2 absorbent material is NOT authorized for the MK 16.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the three causes for failure of the CO2 absorbent material?

A

Channeling of exhaled gas is due to an improperly packed canister.
Water intrusion into scrubber causing CO2 absorbent to become saturated and fail.
Exceeding canister duration limits.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What components make up the center section assembly?

A
Sensor housing
O-rings
O2 sensor connectors
HP tubing connectors
Bendix cable connectors
Horseshoe assembly 
Diluent addition valve
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the O2 sensor connectors?

A

They electronically connect sensors to the primary electronics and to secondary display

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What four systems make up the MK-16?

A

Housing system
Recirculation system
Electronic system
Pneumatic system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The PEA hydrostatic switches at what two depths?

A

33 fsw on descent

13 fsw on ascent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Oxygen Addition Valve lets O2 in to the breathing loop at how many liters a minute?

A

5 liters per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Charging Rate for O2 and Diluent Bottles

A

100 PSI per minute dry

200 PSI per minute wet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The rate at which bypass valves add gas into the loop

A

50 liters per minute