what are 4 types of media that can be used for transmission in camera systems
coax
fiber
twisted pair
wireless
in an orthographic projection there can be up to _____ standard views and _______ of auxiliary views
6
any number
what is a RAID and what is it used for
Redundant array of independent disks
multiple backups in case one becomes corrupted
Category 4 transmission characteristics
Category is considered legacy
Definitions
NFPA 70 article 100
ANSI/TIA 569-D requires __________ sleeves for the first 40,000 square feet of area served by the intrabuilding backbone system, plus one additional sleeve of the same size for every 40,000 square feet after that
five four inch sleeves
Fire stops are used for restoring the integrity of _________ in fire rated materials
penetrations
570-C
Residential Telecommunications infrastructure standard
Name three sources of EMI
transformers
florescent lights
motors and generators
what is the max bend radius for a four pair UTP cable when it is being pulled
4 times cable diameter
name 4 items that shall not be located, installed, pass through, or enter a telecommunications closet
piping not related to the rooms purpose
transformers
motors
generators
as frequency increases _______ increases
attenuation
what are the TIA-570-c requirements for grade 2 cabling
two cat 5e or higher and two 72 ohm coax cable
fiber is optional
How can EMI and RFI problems in telecommunication cables be reduced
use a shielded cable and proper separation from EMI producing objects and your telecommunications cables
what scale uses the 1/2 or 1/4 size concept
mechanical engineers
what is the most common type of print for low voltage construction
floor plan
a ______ cabling system uses standardized media and layout for backbone and horizontal cabling
Structured
signal is measured in _____
Db
NFPA 70 article 250
Grounding and bonding
the ______ of a coaxial cable is used to protect against EMI
Braided shield
the print that shows the location of the structure relative to the lot, road, or to other structures is the
site plan or plot plan
what is the difference between a static and a dynamic IP address
static does not change if node moves to another network while dynamic IP’s are randomly assigned by the computer
what is standard POE voltage
48 VDC
list the 5 most common causes of communication problems
poor termination EMI and RFI bend radius pull too hard and stretch cable staple wires to hard
what is a TBB and what are the minimum and maximum sizes for it
telecommunications bonding backbone - connects the primary busbar to the secondary busbar
6AWG - 750Kcmill
Telecommunications pathways and spaces
569-D
secondary bonding busbar
a busbar placed in each distribution room. bonds all equipment in Distribution room to Ground
ER
Equipment room
what are the installation requirements for plywood backboards in a telecommunications space according to 569-d
3/4 in AC rated plywood size 8' by 4' galvanized, stainless or zink coated fasteners 2 coats of fire rated paint at least one wall covered 6 in above finished floor
Commercial Building grounding (Earthing) and bonding requirements for telecommunications
607-C
civil engineers plot plans most often use a ratio such as
1 inch equals 50 feet
which scale uses measurements like 1/4” or 1/8” equals 1 foot
architects scale
what is the general purpose of notes that relate to blueprint reading
provide additional information that is difficult to determine from drawing
what is the main purpose for CCTV/Network surveillance cameras
protection of assets, people, equipment, and reputation
environmental administration class 1
Single building single equipment room no Distribution Room
fire stops are used for restoring the integrity of ________ walls, floors, and other ________ penetrations
fire rated, fire rated
general requirements for wiring methods and materials
NFPA 70 article 300
name 3 coax connector types
F
BNC
N
list 3 of the most common types of prints for Low voltage construction
floor plan
site plan
elevations
569-D
Telecommunications pathways and spaces
607-C
Commercial Building grounding (Earthing) and bonding requirements for telecommunications
items such as transformers, motors, and generators should not be located in or near telecommunications equipment rooms because of
EMI
RFI
Induced noise voltage
When installing a structured cabling system it is important not to ______, _______, or ________ the cable
twist
Kink
Flatten
PSNEXT is the
undesired coupling of signal energy from a number of simultaneously transmitting pairs into a receiving pair
in a telecom room how far AFF should the lowest 110 block be installed during initial setup
24 inches
optical fiber cabling standard
568-C.3
if a new version of PoE were to come out that was rated to operate at 100 watts over two pairs what would the maximum expected current be in one of those circuits
100/2 = 50 watts per pair I = P/E = 50/48 = 1.04 amps
Electrical metallic tubing: Type EMT
NFPA 70 article 358
community antenna television and radio distribution systems
NFPA 70 article 820
Grounding and bonding
NFPA 70 article 250
what are the two parts of a MAC address
hardware manufacture ID
device individual ID number
what scale, most often used for large plot plans, uses a ratio such as 1 inch equals 50 feet
civil engineers
mechanical engineers scale uses