MALDI Flashcards

1
Q

MALDI Acrynm

A
  • matrix assisted laser desorption ionization
  • soft ionization method useful for macromolecules of >200kDa
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is MALDI

A
  • soft ionization technique which leaves molecules intact
  • can be used for liquid or solid substrates
  • can be interfaced with liquid chromotography and electrophoresis
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

MALDI Mechanism

A
  • sample is mixed with a matrix and allowed to dry which results its crystal formation
  • laser flash ionizes the matrix molecules which in turn transfer protons to the analyte molecules
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

MALDI Specifications

A
  • pulsed laser of wavelength 193-430nm
  • pulse width 0.5-10ns
  • energy per pulse 1X10-7microjoules
  • mean power of pulse 102W-5X103
  • diameter of pulse 10-200micrometers
  • energy per laser pulse and unit area (fluence) 3X10-5 to 60X10-6 microjoules per meter squared
  • laser penetration depth 50-200nm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

MALDI Matricies

A
  • absorb a large amount of energy from the laser thus increasing its temperature by 100-600C
  • the matrix then relays the energy to the sample in controlled amounts allowing the analyte macromolecules to desorb without decomposition
  • matrix also provides a source of protons for the analyte
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

MALDI Matrix Solution

A
  • the mixing and the solvent must be compatable with the analyte so that uniform distribution occurs
  • a plate needs to be spotted for analysis but it can be automated with a fraction collector
  • 1:10,000 ratio of analyte to matrix molecules so that the analyte imolecules are completely isolated from one another
  • coupling of the matrix with the laser causes rapid vibrational excitation and localized disintigration
  • this causes clusters of matrix and analyte to be ejected from the surface thereby leaving the analyte in the gas phase and the matrix as violatile ions
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

MALDI Analyte Ionization

A
  • photoexcited matrix molecules transfer protons via a secondary ion-molecule charge-transfer reaction
  • since catiions can be produced desalting is an important step
  • peptides and proteins typically have higher proton affinities than standard matrix materials
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

MALDI Spectrum

A
  • charge one molecular ion
  • high background at (m/z)<1000
  • suitable for high throughput screening
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Ambient Ionization

A

*

How well did you know this?
1
Not at all
2
3
4
5
Perfectly