What are the system trips associated with the main turbine?

A

MEMBER TORCH ME OE

Manual (2) - P650 & Front Standard

EHC Oil Pump discharge pressure low - 1100 psig (2 out of 3)

MSR high level - 3” (2.5”) below bottom of MSR (10s td)

Bearing oil low pressure - <21 psig

Electrical faults in Generator/Transformers - Generator, Main Xfmr, or UATs

RWL high - 54” (54.5”)

Thrust Bearing wear (proximeter probes) - 35 mils

Overspeed - Primary – 1980 rpm (110%) - Emergency – 1989 rpm (110.5%)

Runback limits (>6466 amps)
< 20,232 amps in 2 mins (total time), and
< 6,466 amps in 3.5 mins (total time)

Condenser low vacuum - 22.3 inches Hg

High vibration (proximeter probes) - 12 mils (need X & Y on the same bearing)

MSOP Discharge Low - < 105 psig (15 sec TD) when above 1300 RPM

Exhaust Hood High Temp - 225°F

Offline ETD trip test

Excessive Acc/Deceleration Trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the auto start features and power supplies for the Motor Suction Pump?

A

Used when <90% speed
Oil booster ≤ 20psig

Power supply: R23-S003 (600V C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the auto start features and power supplies for the Emergency Bearing Oil Pump?

A
Start:
MSOP < 190 psi 
AND
TGOP < 27 psi
OR
TGOP loss AC

Power Supply:
2R22-S016 via 2R22-S018 (125/250 swgr 2C)
1R22-S016 (125/250 swgr 1A)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the auto start features and power supplies for the Lift Pumps?

A

Start:
U1 – Brg Hdr > 6 psigand 0 RPM on turbine speed sensor
U2 – Brg Hdr > 6 psig and TGOP>20 psi(start ckt armed)

Power supply:
R24-S005 (600V MCC A)
Unit 2 - 2R23-S002 - 600B
Unit 1 - 1R23-S011 - 600AA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the start requirements and power supplies for the Turning Gear Motor? What is different if on alternate power supply?

A

Start (must have all 3):
0 - 1.5 RPM
500 psi lift
25 psi EBOP or TGOP

Power Supply:
R23-S003 (600V C) (Normal)
R23-S011 (600V AA) (Alternate

If on Alt p/s, turning gear will not auto start and engage & cannot be started from MCR.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the auto start features and power supplies for the Turning Gear Oil Pump?

A

Start:
MSOP < 200 psig
Brg Hdr < 25/15 psi

Power supply:
R23-S003 (600V C) (Normal)
R23-S011 (600V AA) (Alternate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the power supply for the steam packing exhauster?

A

R24-S005 (600V MCC “2B/1AA”)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are some of the reasons to break vacuum in the main condenser and at what RPM?

A

Condenser vacuum should not be broken until MT <1200 rpm except for emergencies

Fuel element failure
High vibration
Loss of bearing oil pressure
Low steam seal pressure
High MSL Rad
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What value are the TCVs clamped at during normal operation? When does #4 TCV start to open?

A

Clamped at 97% open
TCVs #1, 2, and 3 open simultaneously up to 64% open
When #1,2,&3 @ 64% (~90% RTP), #4 TCV begins to open as required by turbine load (modified partial arc admission)
#4 TCV has limits for opening during operation of 40% (59%) – they are capable of full open during testing (or shell warming)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What stage of the turbine does the first stage reheat steam for the MSR tap off of?

A

Extraction steam from the HP turbine 2nd stage (3rd stage Unit 1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the limitations associated with the Lift pumps? How are they reset?

A

Do not stop lift pumps 1, 5 or 6

Unit 2 - Do not stop more than 3 lift pumps

Unit 1 - No more than 2 stopped when <900 RPM (if #3 stopped, do not stop any other pump)

UNIT TWO LIFT PUMPS

  • If a lift pump has tripped the “armed” or reset pushbutton must be depressed to restart the pump
  • The Control Room switch may be placed to run and the lift pumps will run as long as the switch is held in the “on” position
  • Operator must be sent to reset the relay (arm) pushbutton locally to keep lift pump running
  • Relay panel inside the Unit 2 Turbine enclosure 164 elevation northwest area
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How do you manually trip the main turbine?

A

Both pushbuttons on either P650 or Front Standard must be depressed simultaneously

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the TRM Regulator spec for the main turbine?

A

Mode 1 and 2
TLCO
3 of 3 Throttle press transmitters and 3 of 3 processors shall be FUNCTIONAL
OR
2 of 3 Throttle press transmitters and 3 of 3 processors shall be FUNCTIONAL w/ Eng eval and restoration of 3rd transmitter
OR
1 of 3 Throttle press transmitters and 2 of 3 processors shall be FUNCTIONAL w/ reduced COLR per LCO 3.2.2 and 3.2.3
Conditions
A. All three throttle pressure transmitters or two processors nonfunctional
A.1 Rx Mode switch to SHUTDOWN - Immediately
B. TLCO Not Met other than A.
B.1 Meet TLCO - 24 hrs
C Req Action of B Not Met
C.1 Mode 3 -12 hrs
OR
C.2 Plant management to determine an alternate course of action that continues to assure the safe operation of the plant.
-12 hrs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

How do you determine if the turbine is in shell warming, chest warming or tied to the grid?

A

Looking at the Mark VI display, if TCVs are full open - Shell warming

If ISVs are full open - Chest warming

If showing MWE output as opposed to RPM, then it is tied to the grid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are the vibration limits associated with the main turbine?

A

Vibration limits:
< 800 RPM 8 Mils
800-1400 RPM 14 Mils (10 Mils for 2 minutes)
≥ 1400 RPM 12 Mils (12 on X and Y will trip)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the maximum rate of load change under normal operations?

A

10 MWE/min unless abnormal or emergency

17
Q

What are the turbine lube oil coolers cooled by?

A

PSW

18
Q

When do TCV or TSV closure cause a reactor trip signal to be generated in RPS?

A

> 27.6% power - this is based off of approximately 129 psig first stage pressure, not APRM power readings