How do you reset a magellan and spectra panel?

A

Holding the reset button for 5 second, wait for the flashing and press again within 2 seconds.

Enter programming mode and enter in section 950, then press ENTER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How do you access installer mode and what can you do during this mode?

A

To enter programming mode: Press Enter and enter in the code [0000] (as it should be by default). Programming mode allows you to program all features, options and commands of the control panel.

You CANNOT program users in programming mode.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How do you view the panel’s version number?

A

Enter programming mode and enter section 980.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many remotes and users can you have on a panel? How many users per remote?

A

32 Users and 32 Remotes. Only one user per remote

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is Zone 1 Definition by default?

A

Is an entry delay when fully armed and arms in sleep.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is Zone 2 Definition by default?

A

Is a follow zone when fully armed and arms in sleep.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is Zone 3 Definition by default?

A

Is an instant zone when full armed and arms in sleep.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is a follow zone and what is it also referred as?

A

Follow zones are instant zones unless an entry delay has activated first, then it follows the entry delay timer.

Also referred to as a handover zone.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Do ZX8 Inputs support fire zones?

A

No, for 2 wire smoke installations MG5050, SP6000 and SP7000 zone 1 inputs only support the fire zone definitions. Section 706, option 3 must be enabled.

For 4 wire smoke installations, you can use any panels, on any on-board zone inputs.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How do you enrol wireless zones onto a panel?

A
  1. Go to the wireless zone in programming mode, open up the wireless device physically and activate the tamper switch.
  2. Go to the wireless zone in programming mode and manually enter in the devices serial number.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What setting are not deleted after defaulting the panel?

A

The programmed labels of zones, devices, areas and users.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Which keypad has its own PGM on-board?

A

K32LCD and K32LX however it is not programmable. It will follow the arm status of any partition (Only applies to versions 5.10 and higher and a ECO number of J014).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
Define the default programming for:
PGM 1
PGM 2
PGM 3
PGM 4
A

PGM 1: Strobe
PGM 2: Screamer
PGM 3: Smoke Detector
PGM 4: Garage Door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What are the default programming for zone report codes and what do they mean?

A

Alarm Report Codes: FF
Alarm Restore Codes: FF
Tamper Report Codes: FF
Tamper Restore Codes: FF

FF means that the zone will send a report for the respective settings, otherwise 00 will be programmed meaning it will not send a report. All zones and report codes are FF by default.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the difference between a magellan and a spectra panel?

A

Magellan has a built in 2-way wireless receiver, while spectra need to have an RX1 or RTX3 output to be able to receive and send wireless signals.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the main difference between an RX1 and an RTX3 module?

A
  1. RTX3 can send and receive wireless signals while an RX1 can only receive.
  2. RTX3 comes with 4 additional PGM’s
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Briefly describe re-programming a PGM

A

Program an activation event:
EVENT GROUP - SUB GROUP - PARTITION

Program a deactivation event:
EVENT GROUP - SUB GROUP - PARTITION

or you can program a PGM delay to deactivate the PGM after a set delay. This will make the deactivation even a second activation event.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

How many PGM’s are you able to have on a panel?

A

A total of 16 PGM’s.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

With an installer code of [5743] what does the code become when enabling 6-digit in section 701, option 1?

A

The new code becomes [574357]. As the first 2 digits of the code become the 5th and 6th digit.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What are the default installer code, maintenance code and system master code?

A

Installer Code: [0000]
Maintenance Code: [—-]
System Master Code: [1234]

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Can you bulk program user options?

A

Yes, programming option 400 will program users 4 - 32. User 1, 2 and 3 will not follow option 400 though as they cannot change the options they have by default.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

How do you reprogram the users to be able to send arming and disarming reports? What are the default settings and describe what environment you’d want users to be able to send arming and disarming reports.

A

You reprogram users by entering section 471 - 502 and change arming from 00 to FF, as 00 means it is disabled and FF means it is enabled. Section 801 Option 1 will also need to be disabled which will ALWAYS send an alarm.

The default setting are:

Arming: 00
Disarming: FF

And enabling arming/disarming codes is commonly used for commercial use.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

How many users can be enrolled onto a panel?

A

32 Users

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

How many repeaters can be programmed onto a panel?

A

2 Repeaters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

How to you program a repeater onto a panel?

A

Add the repeater’s serial device number onto the panel, then after you’ll need to enable the option of repeating the wireless signals of the specific zone, module or PGM in sections 551 - 576. All repeating options are OFF by default.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

How many modules can you have programmed into your panel. And how many of those modules can be wireless?

A

A total of 15 Modules can be wired and only 8 of those modules can be wireless.

27
Q

What is the default programming of the buttons on a wireless remote? (REM1/REM2/REM15)

A
The lock key is programmed as 1: 
Regular/Force arming.
One Dot is programmed as 4:
Sleep/Sleep Force arming.
Two Dot is programmed as C:
PGM Activation Event for PGM 1
One+Two Dot is programmed as 8:
Panic 1 Alarm.
28
Q

How do you program a remote onto a panel?

A

Start at the main keypad interface, press the power button and enter in the System Master Code. It’ll then prompt for the user you’d wish to program. Then you’ll need to set a code for the user, press the button remote twice to program the remote to the user and select the partition(s) the user has access to.

29
Q

How many sirens can you have on a panel?

A

5 Sirens, 1 Siren hardwired into the panel itself and 4 wireless sirens can be enrolled onto the panel also.

30
Q

Explain how to zone double.

A

First you need to enable zone doubling in section 705. An example of the zones would be zone 1 = ATZ zone 6.
zone 5 = ATZ zone 10. etc. You will need to wire zone 1 and 6 in the same zone terminal in parallel with zone 1 having a 1k resistor and zone 2 having a 2.2k resistor.

31
Q

What do the 1k and 2.2k resistors look like?

A

1k Resistor: Green with no lines.

2.2k Resistor: Brown with 4 red lines, RED RED RED.

32
Q

What kind of circuit do you use to zone double?

A

You can zone double using both parallel and series, however it is significantly harder to zone double in series. However you are required to zone double in series for the EVO series panel - however CSD Tech support does not support it.

33
Q

If you want to wire two devices in the same zone to trigger the same zone, what kind of circuit do you use?

A

Series circuit as a parallel circuit will not open unless both devices have opened simultaneously.

34
Q

How many bus modules can you have a panel?

A

15 Modules.

35
Q

What are 3 locations you need to program for dialling

A

[811] Account P1
[815] Phone #1
[817] Backup Phone

36
Q

What is a PDX-PGM4 and what does it do?

A

It is an expansion module that allows a panel to have additional hardwired PGM outputs. You can only have one addition PGM4 on a panel.

37
Q

What is a PDX-ZX8/PDX-ZX8SP and what do they do?

A

It is an expansion module that allows a panel to have 8 additional hardwired zone outputs. You can only have 3 additional ZX8 modules.

38
Q

What is a PDX-VDMP3 and what does it do?

A

This module provides a voice-assisted link with the control panel and can be programmed to call one or more telephone numbers in the event of an alarm. You can also call the VDMP3 from an outside line, enabling you to arm or disarm the system as well as activate PGM’s. The VDMP3 essentially turns any outside telephone into a keypad.

39
Q

What is a PDX-PCS260 and what does it do?

A

This module allows the panel to have a 2 way communication with the control centre. It will also communicate with a set mobile number in the case of an alarm, in which it will send an SMS alert.

40
Q

What is the max mA that the auxiliary supply can provide?

A

700mA.

41
Q

What is the max mA that is supplied to a PGM?

A

100mA.

42
Q

What is the MAX current drawn from the BELL and AUX terminals?

A

It is limited to 1.3A, 700mA for the AUX and 500mA for the BELL.

43
Q

What is the max distance a wired keypad can be from the panel?

A

76 meters.

44
Q

What is the maximum total length of wire you can have on a panel?

A

230 meters.

45
Q

What is a PDX-PMC5 and what does it do?

A

This module is a memory key with a USB and 5-pin connector that allows the upload and download of the system programming between modules and BabyWare.

46
Q

What is the purpose of the locking mechanism on a PDX-PMC5

A

While locked, it prevents the data on the device to be overwritten.

47
Q

How many personal phone numbers can be programmed onto a panel?

A

5 phone numbers,

48
Q

How many monitoring station numbers can be programmed on a panel?

A

3 monitoring stations, 2 phone numbers and 1 backup number.

49
Q

What is an PDX-IP150 and what does it do?

A

It is a module that allows you to control and monitor your security system through any web browser and through the Insight Gold Application. Rather than having your panel communicate to your pc directly, the panel will now communicate (through the IP Module) to the swan cloud server and you will be able to access the panel through any pc connected to the internet.

50
Q

How do you enrol the zone on a repeater?

A

Enter in the serial number of the repeater as a wireless device on the specified zone and hard wire a device into the repeater. The hardwired device will act as a wireless device.

51
Q

What is trouble 1 on a keypad?

A

Wireless zone low battery.

52
Q

What is trouble 2 on a keypad?

A

Power trouble.

53
Q

What is trouble 3 on a keypad?

A

Bell Trouble.

54
Q

What is trouble 4 on a keypad?

A

Communication Trouble.

55
Q

What is trouble 5 on a keypad?

A

Tamper and zone wiring failure.

56
Q

What is trouble 6 on a keypad?

A

Module tamper trouble.

57
Q

What is trouble 7 on a keypad?

A

Fire loop trouble.

58
Q

What is trouble 8 on a keypad?

A

Timer loss trouble.

59
Q

What is trouble 9 on a keypad?

A

Wireless zone supervision loss.

60
Q

What is trouble 0 on a keypad?

A

Module supervision loss.

61
Q

What is trouble 16 (K32, K32RF, K37 and K35 Only)?

A

Keypad fault.

62
Q

What is trouble 17 (K37 Only)?

A

Upgrade panel to v3.2 or higher.

63
Q

What is the trouble when SLEEP LED is on?

A

Keypad fault.

64
Q

A zone on a panel will not close. What are the possible faults that may cause that issue?

A
  1. There may be a wireless device programmed onto the panel on the same zone. The panel will always prioritise a wireless device over a hard wired device if it is programmed on the same panel.
  2. Module fault. The module itself may be faulty and may not close the zone. This can be tested by removing the module and wiring a 1k resistor into the zone to see if that will close the zone. If the zone closes then the module is the cause.
  3. Panel fault. As before when removing the module and wiring a 1k resistor into the zone, if the zone remains open then the panel itself is what is faulty.
  4. Programming. The programming may cause the zone to result in it being unable to close, a solution would be to check the zone settings, and after that if the issue still occurs - Default the panel and then test to see if the zone remains open once again.