How do you reset a magellan and spectra panel?
Holding the reset button for 5 second, wait for the flashing and press again within 2 seconds.
Enter programming mode and enter in section 950, then press ENTER
How do you access installer mode and what can you do during this mode?
To enter programming mode: Press Enter and enter in the code [0000] (as it should be by default). Programming mode allows you to program all features, options and commands of the control panel.
You CANNOT program users in programming mode.
How do you view the panel’s version number?
Enter programming mode and enter section 980.
How many remotes and users can you have on a panel? How many users per remote?
32 Users and 32 Remotes. Only one user per remote
What is Zone 1 Definition by default?
Is an entry delay when fully armed and arms in sleep.
What is Zone 2 Definition by default?
Is a follow zone when fully armed and arms in sleep.
What is Zone 3 Definition by default?
Is an instant zone when full armed and arms in sleep.
What is a follow zone and what is it also referred as?
Follow zones are instant zones unless an entry delay has activated first, then it follows the entry delay timer.
Also referred to as a handover zone.
Do ZX8 Inputs support fire zones?
No, for 2 wire smoke installations MG5050, SP6000 and SP7000 zone 1 inputs only support the fire zone definitions. Section 706, option 3 must be enabled.
For 4 wire smoke installations, you can use any panels, on any on-board zone inputs.
How do you enrol wireless zones onto a panel?
- Go to the wireless zone in programming mode, open up the wireless device physically and activate the tamper switch.
- Go to the wireless zone in programming mode and manually enter in the devices serial number.
What setting are not deleted after defaulting the panel?
The programmed labels of zones, devices, areas and users.
Which keypad has its own PGM on-board?
K32LCD and K32LX however it is not programmable. It will follow the arm status of any partition (Only applies to versions 5.10 and higher and a ECO number of J014).
Define the default programming for: PGM 1 PGM 2 PGM 3 PGM 4
PGM 1: Strobe
PGM 2: Screamer
PGM 3: Smoke Detector
PGM 4: Garage Door
What are the default programming for zone report codes and what do they mean?
Alarm Report Codes: FF
Alarm Restore Codes: FF
Tamper Report Codes: FF
Tamper Restore Codes: FF
FF means that the zone will send a report for the respective settings, otherwise 00 will be programmed meaning it will not send a report. All zones and report codes are FF by default.
What is the difference between a magellan and a spectra panel?
Magellan has a built in 2-way wireless receiver, while spectra need to have an RX1 or RTX3 output to be able to receive and send wireless signals.
What is the main difference between an RX1 and an RTX3 module?
- RTX3 can send and receive wireless signals while an RX1 can only receive.
- RTX3 comes with 4 additional PGM’s
Briefly describe re-programming a PGM
Program an activation event:
EVENT GROUP - SUB GROUP - PARTITION
Program a deactivation event:
EVENT GROUP - SUB GROUP - PARTITION
or you can program a PGM delay to deactivate the PGM after a set delay. This will make the deactivation even a second activation event.
How many PGM’s are you able to have on a panel?
A total of 16 PGM’s.
With an installer code of [5743] what does the code become when enabling 6-digit in section 701, option 1?
The new code becomes [574357]. As the first 2 digits of the code become the 5th and 6th digit.
What are the default installer code, maintenance code and system master code?
Installer Code: [0000]
Maintenance Code: [—-]
System Master Code: [1234]
Can you bulk program user options?
Yes, programming option 400 will program users 4 - 32. User 1, 2 and 3 will not follow option 400 though as they cannot change the options they have by default.
How do you reprogram the users to be able to send arming and disarming reports? What are the default settings and describe what environment you’d want users to be able to send arming and disarming reports.
You reprogram users by entering section 471 - 502 and change arming from 00 to FF, as 00 means it is disabled and FF means it is enabled. Section 801 Option 1 will also need to be disabled which will ALWAYS send an alarm.
The default setting are:
Arming: 00
Disarming: FF
And enabling arming/disarming codes is commonly used for commercial use.
How many users can be enrolled onto a panel?
32 Users
How many repeaters can be programmed onto a panel?
2 Repeaters
How to you program a repeater onto a panel?
Add the repeater’s serial device number onto the panel, then after you’ll need to enable the option of repeating the wireless signals of the specific zone, module or PGM in sections 551 - 576. All repeating options are OFF by default.