If a Part 145 Maintenance Organisation is located outside European Union who is the competent authority
EASA
What document does a Maintenance Organisation compile and send to the NAA to gain or amend its approval
Maintenance Organisation Exposition
How often must the man hour plan be reviewed
Three months
What categories of license holder must a maintenance Organisation employ on the line
B1 and B2 (could be one person)
What are CAT A, B1 and B2 license holder know as at base maintenance
Support staff
What category of license holder may release an aircraft to service following scheduled base maintenance
Cat c
What qualifications are needed by an individual to release a component to service
Company authorisation (no part 66 license for components yet)
What training is necessary for Certifying Staff employed in a part 145 maintenance Organisation situated outside the EU
Suitable Foreign Licenses and undergo Human Factors and Legislation Training as well as completing types/tasks training and satisfying the usual experience requirements
To whom must potential Maintenance Organisation certifying staff demonstrate adequate understanding of Aircraft/components as well as organisation procedures
Quality manager/ Department
What 2 statements are being made when a certificate of Release to Service is signed/stamped
- Work was carried out IAW Part 145 procedures
- Aircraft/Component is ready for release to service
For how long must maintenance records be kept for
3 years from date Aircraft was released to service
Within what time period must Occurrence Reports be sent if the the relevant recipients
Within 72 hours but by telephone if urgent and followed up by a report within 72 hours
How often must independent quality audits be carried out in an maintenance Organisation
Every 12 months, all areas must be covered over a 12 month period
What is an MOE and what does it detail
Maintenance Organisation Exposition: how the organisation aims to comply with Part 145. All information will be the for the NAA to issue or re-issue the Part 145 approval.
For how long is a Part 145 Maintenance Organisation approval valid
Unlimited as long as it remains in compliance with the regulations