LTQUESTIONS Flashcards

1
Q

D: Vacant residential fires tend to occur most frequently during the late night to early morning hours, peaking from____

A

10PM -2 AM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Question 1:
Please read all the explanations. They have lots of really good info. This is new material and tends to be highly testable… Question 1…While operating at an odor of gas in an occupied place of assembly, members of Engine 101 encounter the following: A licensed plumber using a 16.4 ounce cylinder of propane with a torch. They would be correct to believe which one of the following?
A:The use is lawful, only if the LPG is being used for emergency repairs.

B: The use is lawful, if being used for minor or emergency repairs.

C:The use is unlawful.

D: The use is lawful, if being used for emergency repairs and provided that the cylinder is never left unattended, and it is removed at the end of the work day.

A

Explanation:
AUC 5, CH 2, ADD 3 P 12
FORMER CAPT TEST QUESTION.
Key word is OCCUPIED, for an occupied place of assembly it is never lawful to use LPG for indoor repairs.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Question 12:
The first due engine captain arrives at a scaffold emergency and he is the initial-on-scene IC for a few minutes. The incident will dictate which resources are necessary. Which of the following are listed in the FDNY’s new and improved Suspended Scaffold Emergencies bulletin as resources that may be needed? **1)-Rescue & Squad, **2)-Medical Assistance, **3)-NYPD, **4)-DOB, **5)-A scaffold mechanic, **6)-Glassier contractors.
A:1,2,3 &4 but not 5&6

B: 1,2,4,5 &6, but not 3

C:1,2,3,4,5 &6

D: 1,2,3,4 &6, but not 5

A

C ALL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

VACCANTS sec. 5.3 Primary searches should generally be conducted after all visible fire has been ______and the IC completed a size-up and risk assessment.

A

KNOCKED DOWN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Out of the four choices listed, which is the proper tool assignment for a unit that is operating at a scaffold incident, where the scaffold is occupied and the need for possible rescue may exist?
A: Rescue and Squad companies will respond in with 1800 feet of ½” Kermantle rope.

B: Extra cans as a water source may be used in the area where walls are being breached.

C: Ladder companies’ complete tool assignment is their assigned tools and the lifesaving rope.

D. ENGINE LSR MAY BE NEEDED

A

Explanation:
Emergency Procedures, Suspended Scaffold Emergencies
A-sec.3.3, Rescue and Squad have high angle equipment, rigging, and glass cutting capabilities. All mentions of the Kermantle rope has been removed as of 1/2020.
B-sec. 7.2, In the area where glass is being cut.
C-sec. 3.3, Complete assignment will be assigned tools, LSR, and

UTILITY ROPES

D-sec. 3.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

NOTE: 400 (SCF) OF LPG is about HOW MANY LBS

A

46
MORE THAN 400 REQUIRES PERMIT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

2ND OV POSITION NO OUTSIDE OPS NO ELEVATOR GOES TYPICALLY WHERE?

FIRST LCC IF NO OUTSIDE OPS TYPICALLY GOES WHERE?

A

FIRE FLOOR WITH OFFICER

FIRE FLOOR, IF 2ND L CO IS DELAYED TEAM UP WITH OV TO APT ABOVE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

VACCANT BUILDING IDENTIFIED ADMIN UNIT FOWARDS MEMO TO

A

ALL UNITS IN FIRST ALARM AREA, BAT, AND DIV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

T/F THERE MAY BE MULTIBLE FLOW PATHS IN A BLDG

A

T

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

WHO PLACES TAGS ON OOS STANDPIPES OR SPRINKS?

A

IMPAIRMENT COORDINATOR

TAGS PLACED AT EACH FDC AND VALVE AND FIRECOMMAND STATION

TAGS INDICATE WHICH SYSTEM OR PART OF IS OOS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

ACRONYM: LESS..L-Life (protection of), E-Extension to exposures, S-Safety of members, S-Structural stability.

A

LIFE MOST IMPORTANT CONCERN DURING SIZE UP

MEMBER SAFTY HIGHEST PRIORITY. MSHP

STABILITY SERIOUS CONCERN

EXTENSION SERIOUS SONCERN

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

TASK FORCE RRV
HOW MANY FF

WHO SUPPLYS TASK FORCE?

A

3-6

TECH SERVICES

NOTE: MEMBERS USE ASSIGNED UNIT DESIGNATIONS TO ID THEMSELVES. EX R16 TO ENGINE 9

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Question 26:
Which of the following ladder companies is the only one that operated according to proper FDNY policy at a vacant building fire?
A: As second due, the Ladder 100 officer assigned 2 members to search all floors above the fire.
B: When the stability of a stairway is in doubt, members should place a portable straight ladder over the stairway. It is imperative that the header beams at the top of the staircase support the ladder.
C: To the extent possible, fire escapes should be avoided.
D: Ladder company operations are generally devoted to ventilation and search.

A

C

Firefighting Procedures, Vacant Building Fires.
A-sec. 5.4 members shall not conduct searches on the floors above until all visible fire is knocked down and the IC completed a size-up and risk assessment. NOTE: have 2 FFs search all floors below the fire has been removed from books 1/2020

D LADDERS DEVOTED TO ENGINE COMPANY GETTING WATER

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Question 36:
As a newly promoted Lieutenant you respond to a scaffold emergency. You mentally review FDNY protocols while in route to the incident. In which consideration below were you most correct?
A: In all instances, the NYPD should cordon off the area below the scaffold to vehicular and pedestrian traffic.

B:All apparatus shall be kept clear of the danger area.

C: All members must only enter the building from an entrance outside of the danger area.

D: The area below the scaffold shall be taped off. This will mark the danger zone for all except operating members.

A

A. UNITS SHOULD CORDON OFF

B. SCAFFOLD WITHIN REACH MAY BE USED.. FOR OCCUPIED ONLY.. UNLESS IMMINENT DANGER USE HIGH ANGLE ROPE

DANGER ZONE FOR ALL CIVILIANS AND PERSONELL INCLUDING UTILITY WORKERS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Discretionary overtime is governed by different guidelines than minimum staffing overtime. Members may work discretionary overtime on a specific day or time when they are granted time off for which of the following reasons?
A: Vacation Leave.

B: Self Mutual.

C: Compensatory Time.

D:None of the Above

A

Explanation:
PAID 1-2009
Sec. 2.7
A,B,C, &D-Members are not eligible to work discretionary OT while on: Vac Leave, Accrued Leave, Terminal Leave, or Comp time or Self Mutual off.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The intent of the “Abandoned Infant Protection Act” is to provide a parent who has no other alternative with a safe place to abandon his/her infant. The fire unit must make a journal entry and forward a letterhead report, with endorsements, to the Chief of Fire Operations. These reports shall indicate all the following information except:

A

A: Date and time custody of the infant was assumed.

B: Precinct and shield numbers of the PD members assuming custody

C: How notified

D: Race and sex of infant.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Question 1:
The intent of the “Abandoned Infant Protection Act” is to provide a parent who has no other alternative with a safe place to abandon his/her infant. The fire unit must make a journal entry and forward a letterhead report, with endorsements, to the Chief of Fire Operations. These reports shall indicate all the following information except:
A: Date and time custody of the infant was assumed.

B: Precinct and shield numbers of the PD members assuming custody

C: How notified

D: Race and sex of infant.

A

Explanation:
AUC 7 sec 2.6.2
Unit designation and shield numbers of ambulance unit members assuming custody
The report also contains… Time custody of the infant was assumed by the ambulance crew.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Question 2:
Proper line placement at rowframes is critical to preventing the rapid extension of fire to exposures. When operating at a fire in a vacant building in a row of occupied rowframes which line placement below is correct?
A:✔The first hoseline must be stretched to the most severe exposure.

B: If not needed to back up the first hoseline, the second hoseline must be stretched to the opposite exposure.

C: The third hoseline must be stretched to the fire building.

D: The fourth hoseline must be stretched through an exposure to the rear yard.

A

B. If not needed to back up the first hoseline, the second line shall be stretched TO THE FIRE BUILDING OR THE OPPOSITE EXPOSURE.

C. The third hoseline is stretched TO THE FIRE BUILDING OR THE OPPOSITE EXPOSURE, DEPENDING ON WHERE THE SECOND HOSELINE WAS STRETCHED.

D. The fourth hoseline is stretched AS ORDERED BY THE IC.

Rowframes 6.7 A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

COLLAPSE CORRECT

C: Initially, the first arriving tower ladder should be the only unit in front of the collapsed building, unless there is specific need for additional units.

D:Subsequent arriving tower ladders should be positioned to reach and protect a different exposure.

A

BOTH TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

OPEN STAIRS DO OR DO NOT HAVE STANDPIPES

A

DO NOT TYPICALLY HAVE STANDPIPES

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Question 9:
Prefixes of units on a response ticket help to identify what resources are responding to a particular incident. Which prefix is correct?
A: HR - High Rise Unit

B: RC - Recuperation and Care Unit

C: F - Foam Tender

D: RV - Rapid Response

A

Explanation:
Comm 2 p36
RA - Recuperation and Care Unit
FT - Foam Tender
RR - Rapid Response
***AUC 159 add 8 sec 3.2.1 states…These units will be identified in the CADS system as follows: R and ladder company number associated with the S.S.L. (R025 is Ladder 25 second piece)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Question 12:
One of the duties of an engine company officer is to ensure the required number of CFR trained members are working on any given tour. Which guideline stated below is correct?
A: Companies officers must ensure 2 CFR members (firefighters or company officer) are working each tour.
B: In order to be in service as a CFR-D unit, there shall be a minimum of two trained members (firefighters only) with current CFR-D certification.
C: During the tour if staffing is reduced to only 1 firefighter and 1 officer, the company shall be unavailable for CFR-D responses.
D: Without two CFR-D certified members, the company may still be dispatched to calls received directly from the public to assist civilians.

A

D

Explanation:
A. Companies officers must ensure 2 CFR FIREFIGHTERS are working each tour.

B. In order to be in service as a CFR-D unit, there shall be a minimum of two trained members (FIREFIGHTERS OR COMPANY OFFICER) with current CFR-D certification.

C. During the tour if staffing is reduced to only 1 firefighter and 1 officer, the company SHALL REMAIN AVAILABLE for CFR-D responses.

NOTE D: WITHOUT TWO CFR-D CERTIFIED MEMBERS, THE COMPANY SHALL NOT RESPOND TO ANY CFR CALLS. THE COMPANY MAY STILL BE DISPATCHED TO CALLS RECEIVED DIRECTLY FROM THE PUBLIC TO ASSIST CIVILIANS.

**BE CAREFUL WITH THE WORDING IN THIS SECTION

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Question 34:
Units are operating at a cellar fire in a private dwelling. The Incident Commander has decided to reposition the first hoseline from the first floor to the cellar. Which guideline below is stated incorrectly when implementing this tactic?
A: This decision can only be made by an Acting Chief Officer or Chief Officer serving as the IC.

B:✔Ladder company members operating on the first floor must either secure a safe area of refuge or be withdrawn before the first hoseline is repositioned.

C: Members operating on the floor above may need to be withdrawn to a safe area if no portable ladders are positioned and readily available.

D: The IC shall transmit an “urgent” message to broadcast this tactic to all member and ensure and acknowledgment is received from all units/members operating in the interior.

A

FIRST FLOOR MUST BE WITHDRAWN BEFORE LINE IS REPOSITIONED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

SAFTY bulletin 7 chapter 4 chart know it cold

A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Question 18:
You are the officer on duty in Ladder 199 when a firefighter calls and advises you that he lost his ID while at a club the night before. Which choice below contains INCORRECT information regarding the loss of a badge or ID?
A:✔The officer receiving notification must record relevant facts in the office record journal.

B: The member must report the loss to the police department, Transit Authority etc. make a diligent search and immediately advise of its recovery or, after seven days, the failure of a search to produce the item.

C:✘The officer shall forward a report forthwith to Personnel containing the member’s information, date & time of loss, date & time reported, to whom reported, and circumstances relating to the loss.

D: If the badge or ID is not recovered in seven days, an additional report shall be forwarded with recommendations, if any, for disciplinary action as per PA/ID 3/75 (Command Discipline).

A

REGULATIONS CHAPTER 16 – UNIT PERSONNEL PROCEDURE
A IS INCORRECT – Relevant facts are recorded in the company journal. 16.2.6A
B – 16.2.6B
C – 16.2.6C
D – 16.2.6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Question 19:
Currently, there are three types of Anti-Chaffing devices that may be encountered in the field. All devices serve the same function and will afford protection when used with the LSR. The description of the Anti-Chaffing device is incorrectly stated in which choice?
A:✘After the LSR has been packed in the carrying case, remove 3 feet of rope and pass the rope through the canvas sleeve from either end of the device

B: After the rope has been passed through the canvas sleeve, grasp the hook of the LSR and pull 1 1/2 arms length of rope through the anti-chafing device. Tie a bowline on a bight on this section of the rope, and place the rope and anti-chafing device in the carrying case

C: When used in a lowering or single slide operation, the anti-chafing device is placed so that the flexible end overlaps the roof or the parapet wall toward the street

D:✔Whenever the anti-chafing device is placed OOS, the officer on duty shall notify Tech Services by telephone and have it immediately replaced

A

Explanation:
Training Bulletins Rope 1 Data sheet 2
A- 2.1
B- 2.2
C- 3.1
D- Whenever the anti-chafing device is placed OOS, the officer on duty shall notify the administrative division by telephone and fax. Have it immediately replaced 4.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

A:Prohibit on and off-duty members present at the time of discovery from leaving premises without permission of the

A

Investigating officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Application of large amounts of water will dilute Methanol, rendering it non-flammable. The concentration of Methanol must be reduced BELOW ____%to be effective

A

20

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

Non operating radio on rig notify who ?

A

A: Notify the Battalion and Division. In

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

STEPS:

  1. COMPLETE SEARCH OF AREA IN QUESTION
  2. REVIEW RESPONSE PRINTOUT
  3. VERIFY INFO WITH DISPATCHER
  4. CONTACT NEIGHBORS, BUILDING SUPER, SECURITY ETC.
  5. 10-92
  6. TAKE MARK IN JOURNAL UPON RETURN TO QUARTERS
A

19-92

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

Question 36:
Which feature of high-rise office buildings is correctly indicated below?
A: High Rise Office Buildings built after 1968 were constructed with a lack of compartmentation.
B: High Rise Office Buildings built before 1945 used construction techniques that resulted in buildings usually between 10 and 20 pounds per cubic foot.
C: High Rise Office Buildings built after 1968 had exterior walls substantially tied to all floors.
D: High Rise Office Buildings built between 1945 and 1968 had ceiling plenums that were extensive and lacked fire stopping

A

A

B) High Rise Office Buildings built BETWEEN 1945 and 1968 used construction techniques that resulted in buildings usually between 10 and 20 pounds per cubic foot.
C) High Rise Office Buildings built BEFORE 1945 had exterior walls substantially tied to all floors.
D) High Rise Office Buildings built AFTER 1968 had ceiling plenums that were extensive and lacked fire stopping.
HROB 2

32
Q

Cellar fires in taxpayers can be debilitating and arduous operations. Which of the following line placements described below is incorrect at a fire in the cellar of a taxpayer?
A: If a hoseline is operating in a cellar or similar area below grade, an additional charged hoseline must be positioned at the top of the interior cellar stairs to extinguish any extending fire and to protect members operating on the first floor. This position should normally be covered by the 2nd hoseline.
B: Entrance to the cellar may be one or more of the following: an interior cellar stairway, an interior trap door, an exterior flush sidewalk door, an exterior stairway, or a horizontal entrance from an adjoining cellar.
C: Cellars of large area or heavy fire conditions may require two hoselines, one advancing and the other charged and ready to operate if necessary.
D: The last member on the hoseline in the cellar must maintain surveillance of the area to the rear for endangering fire or other conditions. A member positioned at the interior entrance to the cellar similarly should monitor conditions for the first floor.

A

C. TWO LINES ADVANCING IN UNISON

33
Q

At flat roof private dwelling fires the life-saving rope should be taken to the roof when there will be a delay in laddering the rear of the building due to attached exposures and/or the height of the building requires the LSR. Who is responsible to bring the LSR to the roof in this situation?

A

1ST ROOF ONLY

34
Q

Which of the following choices contains correct information regarding Fire Department operations at an IED incident, post detonation?
A: Fire units should respond to the POI and Triage Transfer Point with the following equipment: Meters. Skeds, Tourniquets, Triage tags and CFR equipment.
B: FDNY members assigned to a Staging Area must conduct a thorough search of the area for secondary devices.
C: Leave emergency vehicles that were inside of the primary blast/crime scene area in place until the Incident Comnander determines they are safe to move and moving them will not destroy key evidence.
D: In all cases, members should don appropriate PPE, including their SCBA facepieces, and this equipment must be worn and used throughout the entire operation.

A

A. The ladder company officer conducting a search and examination on the fire floor in a private dwelling should be the only one to initiate the request for additional ventilation on that floor ONLY.

35
Q

Question 7:
Which of the following choices contains correct information regarding Fire Department operations at an IED incident, post detonation?
A: Fire units should respond to the POI and Triage Transfer Point with the following equipment: Meters. Skeds, Tourniquets, Triage tags and CFR equipment.
B: FDNY members assigned to a Staging Area must conduct a thorough search of the area for secondary devices.
C: Leave emergency vehicles that were inside of the primary blast/crime scene area in place until the Incident Comnander determines they are safe to move and moving them will not destroy key evidence.
D: In all cases, members should don appropriate PPE, including their SCBA facepieces, and this equipment must be worn and used throughout the entire operation.

A

A

36
Q

Question 15:
In which case below would you expect the dispatcher to assign 3 Engines, 1 Ladder and 1 BC for a single source structural response?
A: Normal Response
B: Fallback Step 1
C: Fallback Step 2
D: Fallback Step 3

A

Explanation:
Note: On a verified second source on Fallback Step 3, 3 Engines, 2 Ladders and 1 BC will be dispatched.
Comm 6 6.4.3 C

37
Q

6.4.2 FALLBACK Triggers

Conditions that can trigger the implementation of FALLBACK include but are
not limited to:

A. Sustained Alarm Rate of ______incidents per hour, for longer than ______minutes (not associated with a single incident).

A

140 , 20

38
Q

FALL BACK TRIGGER
AVAILABILTY OF ENGINE AND LADDER BELOW. ____%

A

50

39
Q

_____ ALARM OR GREATER ON STATEN ISLAND

A

2ND

40
Q

FALLBACK TRIGGER
WEATHER T;/F

1066 T/F
10-60 T/ F

A

ALL TRUE

41
Q

FALL BACK STEP 1

A

1 1 AND 1 ON CLASS 3,
NEAREST ENGINE OR LAD ON ERS BOX

42
Q

STEP 2 FALL BACK

A

10-19 ON CLASS 3, CO, WATER

2ENG 1 LAD 1 BC ON SOC MATRIX

43
Q

FALL BACK STEP 3

A

STRUCTURAL RESPONSE
3 ENG 1 LAD 1 BC

GASS 10-18
NO MINRESP

44
Q

ronym: For trenching

A

VCR

Volume
Ceilings
Roof size

45
Q

Hydrant curb valves

A

In street 17 turns

46
Q

Question 36:
When the IC is considering ordering an exterior hoseline operated into a cellar window to allow for a quick knockdown at a cellar fire in a PD, what is the primary consideration for members operating on the first floor?
A: Operating under the protection of a hoseline.

B: Securing an area of refuge, ensuring a ready means of egress.

C: Exiting the building.

D:Closing the interior cellar door at the top of the stairs.

A

D

47
Q

Items discovered that are not in compliance with the fire code may be enforced with a VO or FDNY summons, or referred to FPOSU (Fire Prevention) via an A-8. Fire code is enforced by the FDNY not DOB.

A

FOWARD an a-8 for all OOS standpipe and sprinklers

48
Q

Question 12:
Which of the following examples is CORRECT according to department policy for engine company operations involving the stretching and teaming of companies?

A: At a heavy fire on the 2nd floor of a 4-story MD involving a four length stretch and reports of people trapped, the 2nd due engine officer contacted the first for permission to stretch a second line.

B: At a heavy fire in a 2-story private dwelling, involving a six length stretch, the 2nd engine officer contacted the first for permission to stretch a second line.

C:At a heavy fire on the 8th floor of a High-Rise Fireproof MD involving a 2 length stretch, the 2nd engine officer contacted the first for permission to stretch a second line.

D:At a heavy fire on the 3rd & 4th floors of a 4-story Multiple Dwelling involving a six length stretch and multiple people trapped at windows, the 2nd engine officer contacted the first for permission to stretch a second line.

A

D d Explanation:
ENGINE OPERATIONS CHAPTER 8,9
D IS CORRECT - 8.4 – Unless the presence of a confirmed life hazard requires the immediate stretching of a second line, the second engine shall augment and assist the first engine.
A – Incorrect – 8.7… In one and two story structures, where the amount of hose required is four lengths or less, the need to assist on the first hose line is not as great and engine companies are generally capable of stretching and operating individually. In such cases, the officer of the second engine company should make contact with the officer of the first engine company to ascertain if their assistance is required. 8.4 – Unless the presence of a confirmed life hazard requires the immediate stretching of a second line, the second engine shall augment and assist the first engine.
B – Incorrect – See A
C – Incorrect – 9.4.3 Due to the complexity of supplying and stretching from standpipe systems, the first and second arriving engine companies shall always operate together in order to ensure prompt and efficient placement of the first hoseline

49
Q

Incorrect – 8.7… In ________story structures, where the amount of hose required is _______ lengths or less, the need to assist on the first hose line is not as great and engine companies are generally capable of stretching and operating individually. In such cases, the officer of the second engine company should make contact with the officer of the first engine company to ascertain if their assistance is required. 8.4 – Unless the presence of a confirmed life hazard requires the immediate stretching of a second line, the second engine shall augment and assist the first engine.

A

One and two storie structures

FOUR LENGTHS OR LESS

50
Q

d Explanation:
BOROUGH RECOMMENDED SECONDARY COMMAND CHANNEL and RECOMMENDED TERTIARY CHANNEL
Queens 4
Brooklyn 5
Manhattan 6
Bronx 7
Staten Island 8
Comm 12 7.1

A

d Explanation:
BOROUGH RECOMMENDED SECONDARY COMMAND CHANNEL and RECOMMENDED TERTIARY
4-5
7-6
8-8
4

CHANNEL
Queens 4 5
Brooklyn 5 8
Manhattan 6 8
Bronx 7 6
Staten Island 8 4
Comm 12 7.1 d

51
Q

c Explanation:
Level A: The highest level of skin and respiratory protection; positive pressure SCBA inside _______chemical clothing.
Level B: The highest level of respiratory protection, but a lower level of skin protection; positive pressure SCBA and a chemical ensemble that provides ___________

A

A VAPER TIGHT

B SPLASH PROTECTION

52
Q

Can a company officer order high pressure pumping????

A

Only an IC at the rank of Battalion Chief (including Acting Battalion Chiefs) or higher may order the use of the High-Pressure Pumping

53
Q

Question 35:
If a defendant refuses to accept a criminal court summons, what action should the issuing fire officer take?

A:Drop the summons in the direct vicinity of the defendant’s feet.

B: If the defendant refuses to open the door, affix it to the door using masking tape.

C: If the defendant rips the summons up, write another one and call the NYPD.

D: If the defendant leaves before you can serve the summons, you can leave it with the defendants 17 year old son.

A

A

WE ONLY AFFIX THE FDNY SUMMONS

54
Q

HIGH RISE MD:

A service elevator shall not be used until it has been evaluated and declared safe for use by the _____

A

COMPANY OFFICER

55
Q

, Question 12:

All officers should be familiar with EFAS. Of the following choices, which is incorrect?

A: EFAS will pick up all HT transmissions within range even if a company is not assigned to the incident. The units will show up in the “Roll Call” screen on the lower half as “Unassigned Units.”

B: If a member transmits a MAYDAY message on their HT, and does not activate their Emergency Alert Button, the member monitoring EFAS shall highlight that member by utilizing the MDT touch screen and manually assign them a MAYDAY.

C:During a roll call using EFAS, when the remote microphone is keyed three times, the member’s riding position will change from red to yellow.

D: EFAS defaults to Tactical Channel 1, though it has the capability of monitoring any of the 16 Channels, including UTAC and NYMAC channels. However, it can only monitor one channel at a time, therefore, a separate Battalion/Division/EFAS equipped vehicle in conjunction with an EFAS trained member is required for each channel in use.

A

c C. YELLOW to GREEN.
B Note: Once a MAYDAY is assigned, a hard copy will print showing the members company, position and time the MAYDAY was assigned.
Comm 9 Add 3 5.2, 6.1, 7.1.6, 8.1,

56
Q

Question 39:
The following features are common in private dwellings and create special fire safety and firefighting problems. Indicate the incorrect statement.
A:✔Some homes provide access to the attic via pull-down type stairs with a rope attached for ease of use. These are lightweight stairs and should not be used for attic access or line advancement unless absolutely necessary.

B: Open joist construction in the cellar combined with heavy fire and an overloaded first floor, may cause an early collapse of the first floor. This can be either a local or a complete collapse.

C: The presence of a stoop at a secondary entrance on the exposure 2 or 4 side of the building may indicate that the entrance leads to a second floor stairway.

D: When multiple secondary entrances (one with a stoop, and one at ground level) are found adjacent to each other on the same side (exposure 2 or 4) of the building, the entrance at the ground level will most likely have a few steps leading to the kitchen and also half flight of stairs leading to the cellar

A

A

57
Q

Times of spray caps

A

Explanation:
10:00 AM - 9:00 PM

58
Q

Question 14:
You’re the company officer of an aerial ladder arriving first due for a fire in a 25x60 NFP multiple dwelling. There are no people showing on arrival. Your unit takes the following actions. Which one is correct?
A: Your LCC positioned the turntable approximately 15’ from the side wall passed on her approach.

B:✔The truck was readied for raising the aerial.

C: When all ladder company operations can be performed efficiently with portable ladders (e.g. where involved and exposed structures are four stories or less in height), the officer shall make every effort to maintain accessibility of nearby hydrants and to allow for in-line pumping.

D: When street conditions does not allow for apparatus to pass another piece of apparatus, the officer shall make every effort to maintain accessibility of nearby hydrants and to allow for in-line pumping.

A

Explanation:
NOTE: 30’ or less in width is a NARROW BUILDING so the following applies:

A. …positioned turntable in CENTER of the building
C. …(e.g. where involved and exposed structures are THREE STORIES OR LESS in height),…
D. When street conditions ALLOW for apparatus to pass another piece of apparatus…

Aerial Ladders 3.4

59
Q

Question 14:
With the fire on the 3rd floor of a 4 story Brownstone type Rowframe, the LCC of the first arriving Ladder Company completed his assignment in which correct choice?
A: Raised Aerial to roof of exposure 2

B: After Roof FF has reached the roof, reposition aerial for VEIS of fire apartment if fire is on the 3rd floor or above when teamed up with the 2nd LCC

C:✔When repositioning Aerial to top floor with fire lapping out of the 3rd floor windows, the LCC will wait until lapping fire has been eliminated, then vent all windows on top floor. Entry into top floor via aerial may then be attempted when the 2nd to arrive Ladder has not already “made” the top floor via interior

D: The LCC must notify the IC of intended destination when leaving the front of the building

A

Explanation:
Rowframes
A- Raised Aerial to Roof of fire building……p-35
B- After Roof FF has reached the roof, wait for completion of roof size-up. If Roof FF indicates no need for rescue, chauffeur will place ladder to top floor for Brownstone type Rowframe…..To fire floor if fire is on 3rd FLOOR OR ABOVE for OLT type Rowframe…p-35
C- p-35
D- Their company officer…bottom of p-34

60
Q

Question 19:
Which of the following tactics is incorrect regarding a dumbwaiter fire in an old law tenement?
A:✔If smoke is venting out of a dumbwaiter bulkhead, the OV firefighter should vent the dumbwaiter bulkhead.

B: It is important that the top floor, cockloft and cellar are checked as soon as possible.

C: If after venting a dumbwaiter bulkhead, the roof firefighter does not see any appreciable volume of smoke venting, the roof firefighter should notify his/her officer.

D: If it is expected that the dumbwaiter shaft is obstructed, the roof firefighter should not probe the shaft with a hook.

4.3

A

Explanation:
A. If FIRE is reported in the dumbwaiter shaft, the ROOF firefighter should vent the dumbwaiter bulkhead.

Note D: Ladders 3 Page 19 NOTE: To ensure an unobstructed outlet for shafts OTHER THAN DUMBWAITER SHAFTS, probe with hook to detect possible presence of a glazed sash or other covering and remove it.

Ladders 3:

Note D: Ladders 3 Page 19 NOTE: To ensure an unobstructed outlet for shafts OTHER THAN DUMBWAITER SHAFTS, probe with hook to detect possible presence of a glazed sash or other covering and remove it.

Ladders 3: 4.3

61
Q

A:✔At an advanced Row Frame fire where multiple floors are involved, LCS delivery should begin at the lowest level and work its way up to the top floor and cockloft area.

A

A:✔At an advanced Row Frame fire where multiple floors are involved, LCS delivery should begin at the lowest level and work its way up to the top floor and cockloft area.

62
Q

Bronx Package - Exam 14
BACK LIST NEXT
Question 15:
Top floor fires in old law tenements often times extend to the cockloft. Operating members need to determine if the fire has entered the cockloft as soon as conditions permit and relay this information to the Incident Commander. Which comment below is correct for members to consider when checking the cockloft for fire extension?

A: When fire is burning in a top floor apartment, it is important for members to wait until the fire is “knocked down” before examining the cockloft.

B: An early inspection can be made by going to a room adjacent to the fire (within the fire apartment only) and opening an observation hole in that ceiling.

C: If fire can be seen burning in the cockloft the observation hole should be immediately expanded to define the extent of the fire.

D:✔It is good practice while waiting for a charged hoseline to ventilate all the windows in the apartment, because once the ceiling is opened the floor will quickly become filled with smoke.

Explanation:
A. When fire is burning in a top floor apartment, it is NOT EFFICIENT to wait until the fire is “knocked down” before examining the cockloft.

B. An early inspection can be made by going to a room adjacent to the fire (IN THE SAME OR ADJOINING APARTMENT) and opening an observation hole in that ceiling.
C. If fire can be seen burning in the cockloft the observation hole should NOT BE EXPANDED UNTIL A CHARGED HOSELINE HAS BEEN POSITIONED.

Ladders 3: 5.9.6 NOTE

A

Bronx Package - Exam 14
BACK LIST NEXT
Question 15:
Top floor fires in old law tenements often times extend to the cockloft. Operating members need to determine if the fire has entered the cockloft as soon as conditions permit and relay this information to the Incident Commander. Which comment below is correct for members to consider when checking the cockloft for fire extension?
A: When fire is burning in a top floor apartment, it is important for members to wait until the fire is “knocked down” before examining the cockloft.

B: An early inspection can be made by going to a room adjacent to the fire (within the fire apartment only) and opening an observation hole in that ceiling.

C: If fire can be seen burning in the cockloft the observation hole should be immediately expanded to define the extent of the fire.

D:✔It is good practice while waiting for a charged hoseline to ventilate all the windows in the apartment, because once the ceiling is opened the floor will quickly become filled with smoke.

Explanation:
A. When fire is burning in a top floor apartment, it is NOT EFFICIENT to wait until the fire is “knocked down” before examining the cockloft.

B. An early inspection can be made by going to a room adjacent to the fire (IN THE SAME OR ADJOINING APARTMENT) and opening an observation hole in that ceiling.
C. If fire can be seen burning in the cockloft the observation hole should NOT BE EXPANDED UNTIL A CHARGED HOSELINE HAS BEEN POSITIONED.

Ladders 3: 5.9.6 NOTE

63
Q

Which tactic was carried out correctly for a fire in a Rowframe?

A: After several minutes of searching for a fire in a Brownstone type Rowframe the Ladder officer communicated to the IC that “we found the fire. Its located on the basement level in the rear”

B: At a top floor fire in a Brownstone type rowframe, the 2nd ladder company will operate on all floors below and relieve the 1st ladder company when necessary

C: For a top floor fire in a OLT type rowframe, the 2nd arriving OV FF will assist both Roof FFs to vent roof of fire building and necessary exposures

D:✔When ever the TL basket is used for roof access the saw and LSR will be brought to the roof

Explanation:
Rowframes
A- Same as Brownstones, the word BASEMENT shall not be used in fireground communications. Refer to basement as “first floor”….sec 5.1.2.A.note…..new as of 8/28/2019
B- Top floor fire Brownstone type, the 2nd ladder will split the company and examine exposures 2 and 4 for extension. The inside team should operate in the most severely threatened exposure….p-41
C- Top floor fire, 2nd OV FF will operate from fire escape for VEIS of the top floor with 1st OV FF or another available member……p-45
D- p-46

A

Explanation:
Rowframes
A- Same as Brownstones, the word BASEMENT shall not be used in fireground communications. Refer to basement as “first floor”….sec 5.1.2.A.note…..new as of 8/28/2019
B- Top floor fire Brownstone type, the 2nd ladder will split the company and examine exposures 2 and 4 for extension. The inside team should operate in the most severely threatened exposure….p-41
C- Top floor fire, 2nd OV FF will operate from fire escape for VEIS of the top floor with 1st OV FF or another available member……p-45
D- p-46

64
Q

Question 34:
Guidelines were written to aid the engine officer in making the decision between 1 3⁄4” and 2 1⁄2” hoselines. Which guideline is incorrectly written?
A:✔The 235 GPM flowrate provided by the 1 3⁄4” hoseline is sufficient to extinguish the majority of fires encountered.

B: When the 1 3⁄4” hoseline is supplied with 50 psi at the 15/16” tip, the nozzle reaction is 68 lbs. This is the force felt by the nozzle firefighter.

C:✘1 3⁄4” hoseline is the primary attack line in the FDNY.

D: The increased speed and mobility of the 1 3⁄4” hoseline enables the nozzle firefighter to more effectively operate the hoseline and direct the water stream as needed.

A

Question 34:
Guidelines were written to aid the engine officer in making the decision between 1 3⁄4” and 2 1⁄2” hoselines. Which guideline is incorrectly written?
A:✔The 235 GPM flowrate provided by the 1 3⁄4” hoseline is sufficient to extinguish the majority of fires encountered.

B: When the 1 3⁄4” hoseline is supplied with 50 psi at the 15/16” tip, the nozzle reaction is 68 lbs. This is the force felt by the nozzle firefighter.

C:✘1 3⁄4” hoseline is the primary attack line in the FDNY.

D: The increased speed and mobility of the 1 3⁄4” hoseline enables the nozzle firefighter to more effectively operate the hoseline and direct the water stream as needed.

65
Q

Question 35:
All requests to ride in Fire Department vehicles by an individual not authorized to be present in a Fire department vehicle must be approved by who?
A: Commissioner of Fleet Services

B: Fire Commissioner

C: Chief of Department

D:✔Chief of Operations

A

Explanation:
Medium and low pressure Distribution Mains are made of steel, plastic, or, if older, cast iron. Cast iron pipe is currently being replaced as it is prone to corrosion and failure, being brittle with low tensile strength.
C) Note: Main valve covers are larger than curb valve/service valve covers to allow servicing and may be round or square.
EP Gas 4.3
:

66
Q

Question 8:
Natural gas is piped to customers along Distribution Mains which may be high, medium or low pressure and Regulator Stations reduce pressure between Distribution Mains of different types. Which choice below contains incorrect information regarding these mains?
A: High pressure Distribution Mains are made of steel and are generally installed below major roads.

B:✔Medium and low pressure Distribution Mains are made of steel or plastic; they will never be made of cast iron as it is prone to corrosion and failure, being brittle with low tensile strength.

C: High and medium pressure Distribution Mains have control valves that are exercised (partially) on a schedule to ensure working order. These valves are generally found near street corners, but may also be located along the street or on the sidewalk.

D: Low pressure (¼ psi) Distribution Mains generally do not have valves and isolating sections of low pressure Distribution Mains requires plugging or “squeezing off” the pipe while still under pressure (live). Only the Utility Company can safely plug or squeeze-off Distribution or Service Mains due to spark hazards.

A

Question 8:
Natural gas is piped to customers along Distribution Mains which may be high, medium or low pressure and Regulator Stations reduce pressure between Distribution Mains of different types. Which choice below contains incorrect information regarding these mains?
A: High pressure Distribution Mains are made of steel and are generally installed below major roads.

B:✔Medium and low pressure Distribution Mains are made of steel or plastic; they will never be made of cast iron as it is prone to corrosion and failure, being brittle with low tensile strength.

C: High and medium pressure Distribution Mains have control valves that are exercised (partially) on a schedule to ensure working order. These valves are generally found near street corners, but may also be located along the street or on the sidewalk.

D: Low pressure (¼ psi) Distribution Mains generally do not have valves and isolating sections of low pressure Distribution Mains requires plugging or “squeezing off” the pipe while still under pressure (live). Only the Utility Company can safely plug or squeeze-off Distribution or Service Mains due to spark hazards.

67
Q

D: The hydraulic hose lines may be coupled or uncoupled with the power unit running, provided the bypass valve is in the backward or dump position

A

Pins

68
Q

Gas Utility Company is required to give an estimated time of arrival (ETA) and their response time is typically within _____minutes

A

30

69
Q

Con Ed rips street for ____ gas’s leak

A

Low pressure

70
Q

Con Ed shuts main for ____ gas’s leak

A

Med or high pressure.

71
Q

IC should CONSIDER having a unit remain on scene awaiting the Utility Company’s response.

A

IC should CONSIDER having a unit remain on scene awaiting the Utility Company’s response.

72
Q

Safe refuge area zone

A

Warm

73
Q

Casualty collection point zone

A

Cold zone

74
Q

D: It is recommended that members quickly meter sewers, manholes and cellars as they retreat from the original operating area after evacuating occupants.

A

True

75
Q

Wrought-Iron Girders unlike cast-iron, which is strong in compression but weak in tension, wrought-iron is equally strong in compression and tension making it a logical substitute in the mid-19th century for horizontal structural elements

A

Wrought-Iron Girders unlike cast-iron, which is strong in compression but weak in tension, wrought-iron is equally strong in compression and tension making it a logical substitute in the mid-19th century for horizontal structural elements

76
Q

Question 13:
During hot weather, responding without Personal Protective Equipment (PPE) is permissible for all of the following runs except?
A: Non-Structural fires

B: BARS Alarms

C:✔Class 3 Alarms

D: Class E Alarms

Explanation:
Non-Structural Fires and Response to BARS Alarms, Non-Fire responses, ERS no contact, and Class E Alarms, and CFR responses
AUC 310 sec 7.2.2

A

Non-Structural Fires
Response to BARS Alarms,
Non-Fire responses,
ERS no contact, and
Class E Alarms, and
CFR responses
AUC 310 sec 7.2.2