LOX Cart Servicing 350005.1 Flashcards
12/01/23
How close should fire protection equipment be during LOX servicing operations
50 ft
p 3
If LOX spills on asphalt or concrete expansion joint sealant, stop servicing or other operations within a _____ ft radius and do not walk or roll equipment over the area for at least how long
20 ft
30 minutes
p 4
LOX carts shall be parked or stored how far from: 1. structures having fire resistant or non-combustible exterior walls or with automatic fire extinguishing systems, 2. combustible structures or sources of ignition, including heavy traffic areas where equipment is in operation, or smoking areas, 3. airplane parking, fueling, or refueling
- 25 ft
- 50 ft
- 75 ft
p 3
Moving speeds for the trailer shall not exceed how fast
20 mph (32 KPH)
p 5
What are the maximum inclines for side to side, up ramp, and down ramp
24 degrees for side to side and up ramp
30 degrees down ramp
p 5
Trailer shall be parked with the park brake handle in what position
full down position
p 5
Do not smoke or permit smoking within _____ feet of trailers in LOX service
50 feet
p 5
after bodily contact with cryogenic liquid transport the patient and keep them what enroute to ER
dry and warm
p 6
If oxygen system has been empty for more than how many hours, or empty after flight, and system pressure is depleted, oxygen system shall be purged prior to servicing with LOX
2 hours
p 9
How big is the ramp inspection of the servicing area
20 ft radius
p 10
Allow system to stabilize with vent cap for how long after servicing
30 minutes
p 11