Low Votlage Flashcards

1
Q

1.1.1

What AWG wire size is capable of carrying the most current?

A

8 thicker Gauge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

1.1.2

What is the standard conductor material for low voltage cable?

A

Is annealed (soft) solid copper

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

1.1.2

What insulation is commonly used on plenum rated cable?

A

PTFE/ Teflon

High temperature insulation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

1.2.0

The NEC requires that low voltage and optical fiber cables be listed and marked with appropriate classification codes?

A

The requirements excludes optical fiber or communication cables that enter a structure and are terminated in an enclosure within 50’ of the entrance.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

1.3.6. Optical fiber cable

Tight buffered optical multi fiber cable is used mostly in what installation?

A

For Indoor cable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

2.1.1 Fish tapes and poles

A fish tape should never be used near?

A

To prevent electrical shock, fish tapes should not be used in or near live circuits.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

2.1.2 power conduit fishing systems

The name of the item that is vacuumed through a run using a fish unit is called a ?

A

(Also called a mouse) or piston

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

2.2.2 determining the pulling location

Two way communication devices are essential?

A

Including walkie -talkies and cell phones are essential to every cable pull.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

2.3.2 preparing conduit pathways

How do you test for hidden obstructions in the conduit?

A

A test pull will detect any hidden obstructions in the conduit before the pull.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

2.3.3 installing a pull line in conduit

Any rope used for pulling cable through conduit should?

A

Any rope used must be designed so that it does not stretch much under tension.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

2.3.5 prepaying cable ends

A Clevis is usually part of the pulling line rope; allows the rope to twist and prevent tangling?

A

When using pulling grips or stockings, a clevis that is part of the stocking is normally used to help connect the pulling rope to the wire grip.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

2.3.5 preparing cable ends

A general rule the maximum amount of pulling tension for UTP cable is?

A

Not exceed 25 foot pounds per cable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

3.1.2 residential unit communication/ data cable requirements and grades

ANSI/TIA-570 provides recommendation for the minimum number of 1 communication outlet in residential unit spaces?

A

Bedroom
Family / great room
Study/ den
Kitchen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

3.1.3 residential cable installation requirements/ considerations

For coaxial cable under a load the minimum bend radius is 20 times the outside diameter of the cable.

A

Under tensile load, or 10 times the diameter, or unloaded unless the manufacturer recommends other wis.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

4.1.7 communication circuits with building

All communication cables can be used in cable trays except for CMX.

A

Communication circuits conductors or cables must not strapped, tapped, or attached by any means to the exterior of any conduit or other race way.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly