Lo2 Flashcards

1
Q

What is the purpose of the regulation valve?

A

To reduce pressure of the refrigerant.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

what action should be taken in the event of an increase of compressor discharge pressure?

A

Bleed air at condenser.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the cause of a noisy compressor?

A

High charge in refrigerant.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Maintenance on the air con system is to be carried out to avoid what?

A

Legionella bacteria.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In a refrigeration system, if the temperature of the sea water to the condenser is very low what will the thermostatic expansion valve allow to happen?

A

The valve will allow liquid to return to the compressor suction.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What will a correct operating expansion valve have?

A

Frosting on the outlet side, but not on the inlet side.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Air conditioning and refrigeration systems use refrigerants that are (1) and have a freezing point (2) the normal operating range.

A

1- Non-toxic
2- Below

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What can be a result of moisture in the refrigeration system?

A

A reduction in pressure at the condenser outlet.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

what is in the final de-oiling filter on and oily-water separator?

A

Coalescing inserts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What will result in high flow-rates through an oily-water separator?

A

Oil carry-over to the outlet of the separator.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What may both engine-room emergency bilge pumps and emergency bilge injection systems pump through?

A

Through the oily-water separator.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is aeration in a biological sewage treatment plant used for?

A

To provide Oxygen to aerobic bacteria and micro-organisms.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What do the stator windings produce in a phase 3 generator?

A

Large currents at supply voltage to the bus-bars.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

With regarding to rotating 3 phase motors a broken supply line conductor may cause what?

A

Hotter running of the motor attended by buzzing/vibration of the motor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Load sharing between AC generators can only be achieved when what is the same?

A

Voltage, frequency, phase rotation and phase displacement.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What causes a high discharge pressure in a refrigeration system?

A

Fouling of the condenser or high coolant temperature.

17
Q

What are the four main components of a refrigerator system?

A

Compressor
Condenser
Thermostatic Expansion Valve
Evaporator