Liquid Penetrant Testing Level 2 (PT-2) Specific Examination Flashcards
A common application of an aluminium block containing quench cracks is to:
(a) Determine penetrant test sensitivity
(b) Compare performance of penetrant materials or processes
(c) Determine effects of mechanical cleaning methods on penetrant test results
(d) Determine effectiveness of cleaning techniques
(b) Compare performance of penetrant materials or processes
- Which of the following is not (!) an advantage of a water washable fluorescent
penetrant process?
(a) Excess penetrant is easily removed with a water wash
(b) It is well suited to testing large quantities of small parts
(c) It is readily removed from shallow discontinuities
(d) It has low cost, low processing time compared to the post emulsified penetrant
process
(d) It has low cost, low processing time compared to the post emulsified penetrant
process
- What is the proper technique for removal of excess penetrant from a part when using a
water washable penetrant process?
(a) Fine spray normal to the surface
(b) Coarse spray normal to the surface
(c) Fine spray at 45 degrees to the surface
(d) Coarse spray at 45 degrees to the surface
(a) Fine spray normal to the surface
- When using a water washable penetrant testing process, why should the water rinse
temperature remain constant?
(a) To avoid changes in rinse efficiency
(b) To maintain the temperature of the part
(c) To avoid over washing
(d) To avoid under washing
(d) To avoid under washing
- Which type of developer would you use to obtain the highest sensitivity test results?
(a) Dry
(b) Non-aqueous wet
(c) Aqueous wet
(d) Lipophilic
(d) Lipophilic
- What type of penetrant process would be best suited to an application at near freezing
temperatures?
(a) Solvent removable
(b) Water washable
(c) Post emulsifiable
(d) None of the above
(c) Post emulsifiable
- Which type of developer does not (!) provide a contrasting background against which
to view penetrant indications?
(a) Dry
(b) Non-aqueous wet
(c) Water soluble
(d) Water suspendable
(b) Non-aqueous wet
- Which type of developer should not be used with a visible dye penetrant process?
(a) Dry
(b) Non-aqueous wet
(c) Water soluble
(d) Water suspendable
(d) Water suspendable
Why might steel parts have a greater tendency towards rusting after penetrant testing?
(a) Penetrant materials are normally corrosive
(b) Penetrant materials residues are hydroscopic
(c) Any protective oils are removed during penetrant testing
(d) This is true only if the developer and penetrant residues are not removed after
testing
(b) Penetrant materials residues are hydroscopic
- The most significant advantage of the visible solvent removable penetrant process is?
(a) Its suitability for penetrant testing of article with rough surfaces
(b) Portability
(c) Its non-corrosive properties
(d) Ability to allow retest
(d) Ability to allow retest
Correct developer coating thickness is indicated by:
(a) An even, snowy white appearance
(b) A slightly pinkish background
(c) A fine, misting spray
(d) A thin, translucent layer
(c) A fine, misting spray
- Which penetrant test processes commonly use the same penetrants?
(a) Water washable
(b) Water washable and solvent removable
(c) Solvent removable and post emulsifier
(d) None of the above
- Mercury vapour black lights may be extinguished if the supply voltage drops below
about:
(a) 120 volts
(b) 90 volts
(c) 220 volts
(d) 200 volts
(c) 220 volts
- When a mercury vapour black light is inadvertently cut off, approximately how long
should it be allowed to cool before attempting to restart?
(a) Not required
(b) 2 to 3 minutes
(c) 5 minutes
(d) 10 minutes
(d) 10 minutes
- The output of a mercury vapour black light depends on:
(a) Cleanliness of its filter
(b) Age of the bulb
(c) Both a and b
(d) None of the above
(d) None of the above
- When a mercury vapour black light is first turned on, what minimum warm-up time is
normally required?
(a) None
(b) 2 to 3 minutes
(c) 5 minutes
(d) 10 minutes
(a) None
- The most important penetrant test processing time to control is:
(a) Penetrant dwell time
(b) Emulsifier dwell time
(c) Water rinse time
(d) Development time
(d) Development time
- A soft aluminium test piece is to be penetrant tested. The piece has previously been
sand blasted to remove tightly adhering soils. What additional surface preparation
should be performed?
(a) Etching
(b) Solvent cleaning
(c) Ultrasonic cleaning
(d) Grinding
(d) Grinding
- Dried, non-aqueous developers are best removed after penetrant testing by:
(a) Solvent cleaning
(b) Wiping with a water dampened cloth
(c) Wiping with a dry towel
(d) Any of the above
(a) Solvent cleaning
- A penetrant which contains an emulsifier is called:
(a) Solvent removable
(b) Water washable
(c) Post emulsifiable
(d) Solvent suspended
(b) Water washable