LINK MONITOR SUBSYSTEM Flashcards
What is the function of the Link Monitor Subsystem?
Signal monitoring and testing
Also to interface with the ALCS and UHF C3 for offline testing of the UHF signals and UHF Communication levels
Where is the Link Monitor Control panel?
P30 bay 1
What is the power requirement for the Link Monitor control panel?
28VDC from 28VDC DISTR 2 PNL
What is the function of the Link Monitor control panel?
To provide primary control of the Variable Attenuator.
What is the location of the Variable Attenuator?
Aft P20 bay 1
What is the function of the Variable Attenuator?
to reduce the UHF RF signal level.
What is the Location of the Step Attenuator?
P30 bay 2
What is the function of the Step Attenuator?
To reduce the RF signal level to the Spectrum Analyzer to prevent oversaturation
Where is the Spectrum Analyzer located?
P30 bay 2
What is the power requirement for the Spectrum Analyzer?
115 VAC 60Hz from P67-3 C/B panel (via the 60Hz distribution box in E15 rack)
What is the function of the Spectrum Analyzer?
To measure the transmitting power of the C3 radio and the TX and RX baseband signals from the UHF C3 radio subsystem.
Where is the Handheld Voltmeter located and what are it’s power requirements?
P30 bay 1 and uses a 9 volt battery
Where is the UHF C3 power meter located?
P30 above MCS Display 3.
What is the function of the UHF C3 power meter?
To measure the forward or reflected power for UHF C3 1,2, and 3.
Each power sensor has ______ element for forward power measurement and ______ element for reflected power measurement?
2,500 Watt sensor
500 Watt sensor