Limitations - FRCs Flashcards
1
Q
ENG OIL PSI - Max (>max RD w/box)
A
120 PSI
2
Q
ENG OIL PSI - Norm (GN)
A
23 - 120 PSI
3
Q
ENG OIL PSI - Min (
A
23 PSI
4
Q
TGT - Max (>max RD)
A
949*C
5
Q
TGT - Trans, 12s (YL)
A
904 - 949
6
Q
TGT - CONT, 2.5m (YL)
A
880 - 903
7
Q
TGT - MRP, 10m (YL)
A
847 - 879
8
Q
TGT - Max during start
A
851
9
Q
TGT - IRP, 30m (YL)
A
794 - 846
10
Q
TGT - MCP
A
793
11
Q
TGT - Norm (GN)
A
0 - 793
12
Q
TGT Limiter - DE
A
879 +/- 5
13
Q
TGT Limiter - SE
A
903 +/- 5
14
Q
Np - Max (>max RD w/box)
A
119
15
Q
Np - ENG OVERSPEED annunciated
A
114
16
Q
Np - Trans, 12s (114 YL w/box)
A
104 - 119
17
Q
Np - Norm (GN)
A
0 - 103
18
Q
Ng - Max (>max red)
A
106.0
19
Q
Ng - Trans, 12s (YL)
A
105.1 - 106.0
20
Q
Ng - Norm (GN)
A
63.1 - 105.0
21
Q
Ng - Min, ENG_OUT annunciated (
A
63.0
22
Q
Nr - Max (>max RD)
A
110
23
Q
Nr - Trans (YL)
A
105 - 110
24
Q
Nr - ROTOR RPM HIGH annunciated
A
105
25
Nr - Norm (GN)
97 - 104
26
Nr - ROTOR RPM LOW annunciated
97
27
Nr - Trans (RD)
0 - 96
28
TQ - Nr <50% - Max (>max RD)
30
29
TQ - Nr <50% - Norm (GN)
0 - 30
30
TQ - Nr <90% - Max (>max RD)
70
31
TQ - Nr <90% - Norm (GN)
0 - 70
32
TQ - DE - Max (>max RD)
115
33
TQ - DE - Trans, 6s, (YL)
101 - 115
34
TQ - DE - Norm (GN)
0 - 100
35
TQ - SE - Max (>max RD)
125
36
TQ - SE - Trans, 6s, (YL)
121 - 125
37
TQ - SE - SE CONT, 2.5m (YL)
111- 120
38
TQ - SE - SE-MCP (GN)
110
39
TQ - SE - Norm (GN)
0 - 110
40
HYD PSI - Trans, 5s, (YL), (>trans RD w/box)
>3410
41
HYD PSI - Trans, 5m, (YL), (>5m RD w/box)
3310 - 3400
42
HYD PSI - Norm (GN)
2700 - 3300
43
HYD PSI - Min (
1260
44
Engine / APU Starter - Start Cycle Interval
60 Sec
45
Engine / APU Starter - <61*F / 16*C start limitations
2 Start cycles with 3 min rest per, then 2 start cycles with 30 min rest
46
Engine / APU Starter - >61*F / 16*C Start limitations
2 Start cycles with 30 min rest per
47
Engine / APU Starter - Dual Engine Starts
Dual Engine Starts are prohibited
48
Engine / APU Starter - Note on fault or aborted start?
After fault or aborted start, wait 30 sec after APU has stopped. After 2 consecutive start attempts wait 20 min. No more than 3 start attempts are permitted in one hour.
49
NGB PSI - Norm (GN)
25 - 100
50
NGP PSI - Min (
25
51
NGB Temp - Norm (GN)
0 - 134
52
NGB Temp - Max (>max RD w/box)
134
53
XMSN PSI - Norm (GN)
25 - 100
54
XMSN PSI - Min (
25
55
XMSN Temp - Norm (<141 GN)
32 - 134
56
XMSN Temp - Max (> RD w/box)
141