Limitations (Ch 5) Flashcards
TGT temp must be below ___ at shutdown.
500O C
Minimum crew requirement (5.4)
Two pilots
If an operational limit is exceeded, what must be done? (5.3)
13-1 entry
Transmission Oil continuous max temp & min pressure (5.5.6)
1050C
30psi
Fuel display turns yellow at what fuel level? (5.5.7)
200lbs
Maximum wind velocity for rotor start/stop? (5.6.1)
45 kts any direction
Operation of engine against gust lock (5.7)
Prohibited
Engine brake maximum Nr for routine use (5.7)
40%
Engine starter limitations - <15OC (5.10.3b)
2 start cycles
3 minute rest
2 start cycles
30 minute rest
Engine starter limitations - 15-52OC (5.10.3c)
2 start cycles
30 minute rest
Minimum time between consecutive engine start cycles (5.10.3)
60 seconds
Fuel boost pump should be used for (5.14)
Emergency procedures
>5000’ pressure altitude
Using JP-4
Maximum 60M takeoff weight (5.16)
22000 lbs
Cargo floor weight capacity (5.16b)
300 lbs/sqft
Maximum stowage compartment capacity (5.17)
125 lbs
Cabin ceiling tiedown capacity (5.18)
4000 lbs
Floor tiedown fittings capacity & quantity (5.18)
5000 lbs
17
Cargo net restraint rings capacity & number (5.18)
3500 lbs
8
Cargo hook maximum capacity (5.19)
9000 lbs
Rescue hoist weight limitation (5.20)
600 lbs
Maximum airspeed with external load (5.21a)
140 kts
Wind speed limitations (5.21e)
Prohibited >45 kts (35 kts with ESSS) from side/rear when
- hovering
- flying into wind (flight + wind speed)
Maximum flight speed with cabin doors open (5.22a2)
145 kts
Opening/closing cabin doors (5.22a3)
Prohibited in flight, only at a hover
Sling load flight limitations (5.25.3.2)
- max 30O bank angle
- max 35 kts rearward flight
Hoist load flight limitations (5.25.3.3)
- max 30O bank angle
- max 35 kts rearward flight
- max 1000 ft/min descent
Maximum slope limitations (5.28a)
15O side or nose up, subtract 2O per 5 kts of wind
6O tail up, prohibited with tail wind >15 kts
Backup hydraulic pump operating limitations (5.32)
FAT // Operating (min) // Cooldown (min)
<90F // Unlimited // None
91-100F // 24min // 72min
101-126F // 16min // 48min
APU operating limitations (5.33)
>109F, 30 min max if rotors turning
CEFS refueling limitation (5.37)
Fill no more than 3” below the foward edge of filler port, to allow for expansion