Limitations Flashcards
NR Limits
. 110 Maximum (>110 red)
106-110 Transient operation (yellow)
106 High rotor warning annunciated
95-105 Normal operation (green)
0-94 Transient operation (red)
Engine Oil Pressure (PSI)
. 120 Maximum (>120 red w/box)
23-120 Normal operation (green)
23 Minimum <23 red
Hydraulic Pressure (PSI)
. >3410 Transient – permitted for 5 sec(yellow)
(≥5 sec red w/box)
3310-3400 Transient – permitted for 5 min (yellow)
(≥5 min red w/box)
2750-3300 Normal operation (green)
1260 Minimum (<1260 red w/box) 2600 Minimum for APU start 1650 Accumulator Pre-charge
Air Turbine Starter (ATS) Limits
NOTE: 60 seconds between cycles.
Engine Starts At Ambient Temperatures of 61° F (16° C) and Below. (2–3–2–30) • 2 consecutive start cycles; • 3 minute rest; • 2 consecutive start cycles; • 30 minute rest.
Engine Starts At Ambient Temperatures
Above 61° F (16° C). (2–30)
• 2 consecutive start cycles;
• 30 minute rest
Dual engine starts — Prohibited.
TGT Limiter
Single Engine: 903 ±12 (891-915)° (SEC)
Dual Engine: 879 ±12 (867-891)° (MRP)
ENG Np (%) Digital Readouts
. 121 Maximum (>121 red w/box)
115 Engine overspeed annunciated
106-121 Transient operation, 12 sec (yellow, w/box at 115)
0-105 Normal operation (green)
ENG1 Ng (%) Digital Readouts
. 106.0 Maximum (>106.0 red)
- 1-106.0 Transient 12 sec (yellow)
- 1-105.0 Normal operation (green)
63.0 Minimum engine out warning annunciationed (<63.0 red w/box).
Torque (%) Digital Readouts with NR <50%
. 30 Maximum (>30 red)
0-30 Normal operation (green)
Torque (%) Digital Readouts with NR <90%
. 70 Maximum (>70 red)
0-70 Normal operation (green)
Torque (%) Digital Readouts – DE
. 115 Maximum (>115 red)
101-115 Transient 6 sec (yellow)
0-100 Normal operation (green)
Torque (%) Digital Readouts – SE
. 125 Maximum (>125 red)
123-125 Transient 6 sec (yellow)
111-122 Single Engine Contingency 2.5 min (yellow)
110 SE maximum continuous power (green) 0-110 Normal operation (green)
CAUTION: Prolonged APU Operations (NR)
Avoid prolonged operation at 94% - 96% NR with the APU running.
APU Operating Limitations (Starts)
APU operation is prohibited during normal flight.
(30 - 2 - 20 - 3)
After a fault/aborted start wait 30 seconds
After 2 consecutive start attempts, wait 20 minutes.
No more than 3 start attempts are permitted in one hour.
CAUTION: XMSN Temp
Do not operate the APU for more than 5 minutes at a XMSN TEMP of 120 - 130°C.
Extended APU Ground Operations
During prolonged ground operations (>30 min), if the temperatures exceed 130°C, shutdown and cool the transmission fluid for 30 minutes prior to resuming APU ground operations.