Maximum allowable baggage compartment deck loading?
Maximum allowable total weight?
86 Lbs. per square foot.
250 Lbs.
Flight with any combination of doors removed is approved however if the litter door is removed what do you have to do?
The left passenger door shall be removed.
Minimum Cockpit weight at fuselage station 65 is?
170 lbs.
Maximum approved Gross Weight for flight with jettison able external load?
4550 LBS.
Basic VNE.
130 KIAS to 3000 Hd. Decease VNE accordance with placard.
VNE when at 75-100% Torque.
84KIAS or placarded Vne whichever is less.
Vne with doors off?
90 Kias or Vne whichever is less.
VNE autoroation?
100 Kias.
Maximum operating Altitude?
20,000 Feet hp,
Maximum Density Altitude is 10,000 feet when gross weight exceeds?
4150?
Max ambient Temp allowed.
51.7 C decreases with Hp at standard lapse rate of 2 C per 1000 Feet.
minimum ambient operating temperature.
- 50 C.
Maximum ambient temp for use of engine anti-ice.
5 C.
At what temps must Engine anti Icing and pitot heat shall be on.
5 C.
Fuel control Heater shall be on at ____ and must be off at ___?
Below 10 C and above 21 C.
Generator
Continuous operation.
Max operation?
0-90% (0-180 amps)
Max: 90% 180 amps.
Starter Limits (External power.)
40 Seconds On 30 Seconds Off 40 Seconds on 30 Seconds Off 40 Seconds on 30 MINUTES OFF.
Starter Limits (Battery Start)
60 Seconds ON 60 Seconds Off. 60 Seconds On. 60 Seconds Off 60 Seconds On 30 Minutes Off.
Type of Power Plant
Rolls Royce 250-C30P
N1 Limits
Continuous operation. 63 - 105%
Max Continuous 105%
Transient, 106% 10 seconds
N2 Limits
Avoid Continuous Operation 71.8 to 91.5% Minimum 99% Continuous operation 99-101% Max Continuous 101% Transient, 104% (5 Minutes)
Turbine Outlet Temperature Power on.
Continuous operation 100-716 C Max Continuous 716 C Takeoff, 5 Minutes 716 to 768 C Power on Transient 871 C 10 Seconds. Warning: Exceeding 768C TOT or 100% Torque can cause N1 topping with resultant rotor RPM Droop Intentional use of power transient TOT above 768C is Prohibited.
Turbine outlet Temp Starting Limits
Beginning of 10 Second time limit for start 826 C.
Maximum starting and shutdown 927 C.
Do not exceed 10 seconds above 826 C or 1 second at 927 C.
Torque Limits
Continuous: 0-75% Max Continuous: 75% Takeoff, 5 minutes 75 - 100% Transient 105% 5 second. Use of Takeoff power is limited to 84 KIAS or placarded Vne.
Rotor RPM Power on
95% 5 second Transient
99% minimum
99-101% Continuous
104% transient 5 minutes
Rotor RPM Power Off
Minimum 90%
Continuous operation 90 - 107%
Maximum
107%
Jet A ambient Temperature limitation.
-32 C
Rotor brake
Nr decreased to between 38% and 30%
Do not start with rotor brake engaged.
Max Gross Weight internal.
4450 lbs.