Level 2 - South Kensington (NRM Quantification) Flashcards
1
Q
What was the Net:Gross efficiencies on South Kensington?
A
Ranged from 72 - 75%
2
Q
What would you expect a typical Net:Gross on a commercial and residential building?
A
Resi = 70 - 80% Commercial = 75 - 85% depending on circulation and amenities
3
Q
What are key factors that effect the Net:Gross?
A
Circulation
Plant
Shape
How efficient the floor is
4
Q
How did you quantify upper floors on South Kensington?
A
Post Tensioned RC concrete Slabs - 250mm thick
£230/m2
Slab - m2 (stating the thickness)
Reinforcement rate - kg/m3
Formwork - m
5
Q
How did you quantify External Walls on South Kensington?
A
Various facade types = m2
Extra over allowances for plinths and expression beams
£900 - 1,300/m²
6
Q
What was the external wall build up on South Kensington?
A
A mix of: