Overturned Gasoline Tank Trucks/Trailers:
Gross weight of the vehicle, tank and product can be as much as ____ pounds
80,000
‘00 ALF- the “low fuel” indicator light will illuminate when approximately ___ a tank of fuel remains
1/8th
‘00 ALF- Length and width of apparatus?
Length- 54’10”
Width- 10’5”
When the V-Vac suction sliding handle is in the longest stroke position, each squeeze will cause up to ____ ml of fluid to be drawn into the cartridge
150 ml
‘00 ALF- Normal oil pressure operating range @ idle and @rated?
12 psi min @idle
50 psi min @rated
Lamella arch roof- size of wood framing?
Size of sheathing?
- 2x12”
2. 1x6” sheathing
Tied truss arch- size of top chord members?
Rafter size?
Sheathing size?
- 2x12” or larger
- 2x10” or larger
- 1x6” straight or diagonal (1933)
What are the dimensions of decking used in space, straight and diagonal sheathing?
1x4 or 1x6
Gasoline Tank Truck/Trailer Incident-Leak, No Fire:
Eliminate potential ignition sources a minimum of ___ feet from the spill
100ft
Fire Code: For sprinkler systems with 301 to 1,000 sprinklers, provide ___ spare sprinkler heads.
12
Fire Assembly, Automatic-closing – A fire assembly which may remain in an open position and which will close automatically when subjected to an increase in temperature(maximum rating of ___° F.) or the actuation of a smoke detector.
165 degrees
All Hazardous Materials exceeding ___ Ibs. for solids are required to be disclosed by an occupancy for inspection
500 lbs
Fire Code: Fire lanes shall be posted with signs not less than __ inches wide by __ inches high.
17” X 22”
Fire Code: On smooth ceilings, a spacing of ___ feet between smoke detectors may be used as a guide where total coverage is required
30 ft
When on scene of a crashed airplane at LAX, provide a ____ foot perimeter around the plane?
300 feet
Fire Code: Maintain all weeds and grass at a height of no more than ___ inches, if such weeds or other vegetation are within ___ feet of a building or structure located on such property or on adjacent property.
3 “
200 ft
‘00 ALF- How many quarts of 15w-40 engine oil are needed for an oil change not including the oil filter?
34 qts
Vol 6:
Aircraft Inventory Sheets will be required on those aircraft over _____ pounds in weight and in daily operation at the airport.
12,500
AOTM:
the best climbing angles on the aerial ladder are from ___ to ___ degrees inclination from horizontal
70-80
Hotel – Any building containing ___ or more guest rooms intended or designed to beused, rented, or occupied for sleeping purposes by guests.
6
Gasoline Tanker Incident– Fires Involving Spilled Liquid or Tanker:
•When considering an offensive attack, plan for a ___ minute supply of concentrate for suppression operations.
•Plan for an extra ___ minute supply of concentrate for foam blanket maintenance
15 and 15
Within ___ feet of every dispenser there shall be located at least one portable fire extinguisher having a minimum rating of 2A,20B:C.
75 feet
The most efficient way to suction with the V-Vac is with a slow, steady stroke of __ to __ seconds in length
1-2
Metal gusset plate roof- commercial building plywood thickness?
Plywood thickness for dwellings?
- 1/2”
2. 3/8” or 1/2”
On the ‘00 ALF-LTI, the high water temperature indicator light will illuminate when temperature rises above what degrees?
230 degrees F
LAFD apparatus should be considered as over-speeding at anytime the engine rpm’s exceed ___% of the peak engine speed.
90%
AOTM Aerial Ops- When set correctly, the offside ground jack may leave the ground ___ inch(es) or more but resets itself when the aerial is brought back in line with the trailer
1” or more
Fire Code Residential Occupancies- Smoke detectors shall be maintained in dependable operating condition and tested every ___ months or as required by the Chief
6 months
Fire code: stairwells
Stairwell signs shall be square in shape with a minimum dimension of ___ inches.
12
Fire Code: An approved automatic or manually activated local fire alarm system shall be provided for:
Every hotel ___ or more stories in height or containing ___ or more guest rooms.
3 stories, 20 rooms
Fire Code: An approved automatic or manually activated local fire alarm system shall be provided for:
Every apartment house ___ or more stories in height or containing ___ or more dwelling units.
3 stories, 16 units
‘06 ALF- Normal oil pressure operating range @idle and @rated?
10 psi min @ idle
30-45 psi min @ rated
Fire Code: Remove any portion of a tree which extends within ___ feet of the outlet of a chimney or stovepipe
10 ft
Radios:
Zone ___ is the “supplemental” tactical channel zone. It can be used for drills, staging or other operations not requiring operation on the repeated simulcast system. All channels are in “direct” mode
4
Guy wires may be attached to a roof structure having a slope of less than ___ degrees provided there is full clearance of ___ feet or more between the roof and said obstruction
30 degrees
7 ft
Fire Code:
How many pounds or less of Class B explosive materials is exempt from the Division 4 permit requirement?
3 1/2 ft
Fire code:
An unobstructed passageway shall be provided around any approved structures or equipment installations on roof surfaces. One access passageway shall be provided for every ___ feet length or fraction thereof.
50ft
The V-VAC is a hand powered suction device comprised of a handle and a single use ___mil disposable pump cartridge
425 ml
For grooming standards, hair bulk shall not exceed how many inches?
1 1/2”
What is the max time you should manually preheat the onan generator?
30 secs
On the ‘00 ALF-LTI, the “Brake System” indicator light will illuminate when air pressure falls below ___ to ___ psi.
65-75 psi
What year required pre-1933 parapet walls not be higher than 16 inches including the bond-beam cap?
1959
Gasoline tank truck incidents:
A single tank truck with three axles can carry ____ gallons of product.
5,000
Gasoline tank truck incidents:
A tank tractor with a semi-trailer can carry ____ gallons of product. The one tank is approx ___ ft long.
- 9,000
* 40
What year implemented the requirement of Smoke Control Systems (Uniform Building Code) in high rise buildings?
1996
Every rack or pile of tires shall be kept at least ___ inches below sprinkler heads in a sprinklered building.
18 inches
Vol 2:
Maximum reimbursement for watches is limited to _____ except by approval of the C.A.O. in extraordinary circumstances.
50.00
Fire Code High Rise: The standby power generator should activate within ___ sec of electrical system failure.
The emergency power supply system shall be automatically transferred and operated within __ seconds of electrical system failure.
60 seconds
10 seconds
Fire Code: Fire escapes shall have a minimum dimension of __ inches when open. The sill shall be not more than __ inches above the floor and landing.
29 inches
30 inches
Fire Code: Where access requires accommodate of Fire Department apparatus, overhead clearance shall not be less than ___ feet.
14 ft
New fire code states both 14’ (LA) and 13 feet 6 inches
Fire Code: Those portions of a fire lane which must accommodate the operation of Fire Department aerial ladder apparatus shall have a minimum clear roadway width of ___ feet when no parking is allowed on either side.
28 ft
Lightweight trusses- Eighteen-gauge “roof truss clips” may be found nailed to the bottom chord of every how many trusses?
3-5
Fire Code- An aisle passageway in a place of occupancy shall be at least ___ feet wide to allow access to exits, fire protection equipment, or separation for a storage area.
3
‘06 alf onan
when the generator logic control is set for AUTO, the generator will start when the house batteries are below ____ volts and will run until the battery voltage has exceeded ____ volts for one hour.
12.1 and 13.3
Fire Code: All Fire Department sprinkler and standpipe inlet connections shall have a sign not less than ___ inches in width and ___ inches in height
8” width
4” height
Fire Code Warehouse Storage: A clearance of at least ___ inches shall be maintained between stored materials and lighting fixtures
18 inches
‘00 ALF- How many quarts of 15w-40 engine oil are needed for an oil change including the oil filter?
38 qts
Fire code new high rise:
The Fire Control Room shall be separated from the remainder of the building by not less than ___ hour fire-resistive construction with all openings protected by assemblies having a fire-resistive rating of not less than ___ minutes.
1 hr
45 min
Holmatro 3020 UL Cutters:
What is the cutting force? Max Opening?
Weighs 27-1/2 lbs
63,400 lbs
5-1/4” opening
Adjust heating and air conditioning thermostats to start heating when temperature drops below ___°F and cooling when temperature is above ___°F. Window units shouldn’t be turned on until temperature is above ___ degrees Fahrenheit.
68°
78°
78°
Fire Code Warehouse Storage: Where storage consists of large, tightly-packed piles of baled, sacked, or cased material, the distance below sprinkler heads shall be a minimum of ___ feet.
3 feet
Radio Comms:
LAFD portable radios transmit 2 or 4 Watts of power and have a transmit range of up to about ___ to ___ miles in “simplex” or direct mode under the best of conditions
2-3
Gable (conventional)- size of ridge board (if present)
1x6” or 2x6”
All Hazardous Materials exceeding ___ gal for liquids are required to be disclosed by an occupancy for inspection.
55 gallons
Fire code brush: Maintain all grass and weeds within ____ ft of a combustible fence or roadway to a max height of ___ inches.
10 ft
3 inches
Which maxi force air bags are included in the 7 bag system?
12, 17, 22, 32, 35, 44, and 74 ton bag (one of each)
Tied truss arch- size of tie rods?
5/8th”
What thickness is plywood found in on a newer conventional flat roof?
3/8-5/8”
The V-VAC has a shelf life of ___ years when properly stored
5
Fire Code Warehouse Storage:
- A Main Aisle is an unobstructed way of egress at least ____ feet in width.
- A Side Aisle is an unobstructed secondary way of egress not less than ___ feet in width and transecting Main Aisles.
8 feet
4 feet