Lesson 10 Flashcards

1
Q

Everyone, except qualified employees, must stay at least ? from apparatus energized up to 50,000 volts.

Select one:

a. 4’
b. 6’
c. 8’
d. 10’

A

d. 10’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A qualified worker must be trained and have the ability to recognize ? .

Select one:

a. energized parts
b. grounded lines
c. hazardous situations
d. various protective devices

A

a. energized parts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A qualified individual understands that all conductors must be ? .

Select one:

a. considered energized until proven to be otherwise
b. grounded before testing for voltage
c. tested for continuity before energizing
d. tested twice to verify voltage

A

a. considered energized until proven to be otherwise

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
The normal operating voltage of electrical equipment must be determined by workers   ?  .
Select one:
a. before work begins 
b. from previous knowledge 
c. when it is convenient to do so 
d. while work is in progress
A

a. before work begins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Objects that are (insulated) from ground are ? .

Select one:

a. conductive and can be expected to be energized
b. considered grounded
c. protected from an overvoltage event
d. safe to handle

A

a. conductive and can be expected to be energized

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Conductors are the part of an electrical system that carries electrical current.

Select one:
True
False

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Electrical circuits may be in a(n) ? configuration.

Select one:

a. conductive
b. inductive or capacitive
c. transformation
d. wye or delta

A

d. wye or delta

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The neutral conductors are normally connected to the ? .

Select one:

a. ground
b. guy wires
c. insulators
d. lightning arresters

A

a. ground

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The parts of an electrical system used to isolate conductive (energized) material from other parts are called ? .

Select one:

a. grounded devices
b. insulators
c. protective devices
d. stand offs

A

b. insulators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The operating voltage of an insulator can be determined by the ? , its length, or its height.

Select one:

a. insulators’ material make-up
b. number of layers (skirts)
c. pin type
d. support design

A

b. number of layers (skirts)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The piece of equipment used to step the voltage up or down in an electrical system is called a ? .

Select one:

a. capacitor
b. regulator
c. transformer
d. transmission line

A

c. transformer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When a voltage condition occurs that is higher than the designed voltage for the system, a(n) ? becomes a path to ground.

Select one:

a. arrester
b. capacitor
c. switching station
d. transformer

A

a. arrester

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Guy wires cannot become energized because they are tied to rods in the earth.
Select one:

True
False

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The connection point between an underground cable and an overhead conductor is normally made through a ? .

Select one:

a. capacitor
b. pothead
c. splice
d. transit point

A

b. pothead

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Ways to determine the actual operating voltage of a power line include asking an authorized company representative, observing nameplate information, and ? .

Select one:

a. checking the size of insulators
b. fuzzing the line
c. tracing the line back to the substation
d. using test instruments

A

d. using test instruments

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The approach distance to a 12,000-volt line phase-to-phase is ? .

Select one:

a. 2’ 2”
b. 2’ 7”
c. 2’ 10”
d. 3’ 6”

A

a. 2’ 2”

17
Q

The electrical factor distance and human factor distance are also called the ? .

Select one:

a. design factor difference
b. minimum approach distance
c. minimum insulator factor
d. nominal factor distance

A

b. minimum approach distance

18
Q

The term nominal voltage means the ? .

Select one:

a. average voltage on a circuit
b. highest voltage a circuit carries
c. lowest voltage a circuit normally carries
d. normal operating voltage

A

d. normal operating voltage

19
Q

A Qualified Electrical Worker must be ? .

Select one:

a. able to determine the nominal voltage of exposed live parts
b. part of a random drug/alcohol testing program
c. physically fit for the job
d. trained by the IBEW

A

a. able to determine the nominal voltage of exposed live parts

20
Q

Most electrical conductors are made of copper, aluminum, or ? in older systems.

Select one:

a. brass
b. nickel
c. silver
d. steel

A

d. steel

21
Q

The device used to automatically raise or lower the primary voltage of a line to ensure its optimal voltage range is a ? .

Select one:

a. breaker
b. recloser
c. regulator
d. transformer

A

c. regulator

22
Q

A capacitor stores electrical energy.

Select one:
True
False

A

True

23
Q

Insulators installed in guy wires are intended to protect ? .

Select one:

a. a climber from making a ground contact
b. people and equipment on the ground
c. the ground rod from electrolysis
d. the pole or structure from becoming energized

A

b. people and equipment on the ground