What is the purpose of the LenelS2 OnGuard® Field Hardware Crib Notes?
The LenelS2 OnGuard® Field Hardware Crib Notes is a guide intended for screen resolution maximization and electronic distribution, providing installation, upgrade, and hardware information for LenelS2 products.
What should be considered for the liability and product disclaimers of LenelS2 products?
LenelS2 products are not intended for life-critical control applications, and the company is not liable for loss or damage caused by misapplication or malfunction of the product. LenelS2 does not guarantee that its products will work properly in all environments and applications.
What is the operating temperature range for the LNL-AL400ULX power supply?
The operating temperature range for the LNL-AL400ULX power supply is 0° to +49° C (32° to 120° F).
What are the main features of the LNL-600X6-CE220 power supply?
The LNL-600X6-CE220 power supply has a 12 VDC (6A output), 230 VAC input, continuous supply current with enclosure, lock, and UPS capability (battery optional), with an operating temperature range of 0° to +49° C (32° to 120° F).
What should be done before connecting devices to the power supply?
Measure output voltage to avoid potential damage.
What are the RS-485 communication wiring guidelines?
Use low capacitance shielded cable with 2 twisted pairs, maintain a maximum distance of 4000 feet for the main run, use daisy chain configuration, and terminate cables at both ends with RS-485 terminators.
What sections are covered in the LenelS2 OnGuard® Field Hardware Crib Notes?
- Hardware Basics
- Intelligent Single Door Controller LNL-X2210
- Intelligent Single Door Controller LNL-2210
- Intelligent Dual Reader Controller LNL-X2220
- Intelligent Dual Reader Controller LNL-2220
- Intelligent System Controller LNL-X3300
- Intelligent System Controller LNL-3300
- Intelligent Dual Reader Controller LNL-X4420
- Intelligent Dual Reader Controller LNL-4420
- Input Control Module LNL-1100 Series 3
- Input Control Module LNL-1100 Series 2
- Output Control Module LNL-1200 Series 3
- Output Control Module LNL-1200 Series 2
- Single Door IP Interface Module LNL-1300e
- Single Reader Interface Module LNL-1300 Series 3
- Single Reader Interface Module LNL-1300 Series 2
- Dual Reader Interface Module LNL-1320-Series 3/Series 3B
- Dual Reader Interface Module LNL-1320 Series 2
- OSDP Reader Interface Module LNL-1324e
- Star Multiplexer LNL-8000
- BlueDiamond Readers
- LenelProx Readers
What are the key features of the LNL-X2210 Intelligent Single Door Controller?
The LNL-X2210 provides decision making, event reporting, and database storage, supports TTL, F/2F, or RS-485 devices, and requires PoE or 12 VDC power.
What is the recommended grounding method for the LNL-X2210?
Connect earth ground to the panel at the screw next to the Ethernet Connector before making other connections, preferably using a grounding rod or cold water pipe.
What are the default communication parameters for the LNL-X2210?
- IP address: 192.168.0.251
- Subnet Mask: 255.255.0.0
- Default Gateway: 192.168.0.1
- DNS Server: 192.168.0.1
- Primary Host port: IP server, Data Security: TLS if Available, port 3001
What series does the LNL-1100 belong to?
The LNL-1100 belongs to the Input Control Module Series 3 and Series 2.
What is the function of the Output Control Module LNL-1200 Series?
It controls output devices and comes in Series 3 and Series 2 variations.
What are the steps for installing the LNL-AL400ULX power supply?
- Mount the enclosure
- Connect unswitched AC power
- Secure green wire lead to earth ground
- Keep power limited and non-power limited wiring separate
- Connect devices to terminals
- Use batteries for UL Access Control applications
How do you perform a bulk erase on the LNL-2210?
- Set S1 DIP switches to 1 & 2 ‘ON,’ 3 & 4 ‘OFF.’
- Apply power and watch for LED patterns
- Change switches 1 or 2 to ‘OFF’ within 10 seconds
- Wait for LED 2 to flash indicating memory erase