Laser Procedure Properties Flashcards
1
Q
Pre op drops of SLT
A
Alphagan
2
Q
Power for SLT
A
0.8-1.2 mJ
3
Q
Off set for SLT
A
Non
4
Q
Total shots of SLT
A
100 (50/180)
5
Q
Post op drops for SLT
A
Alphagan
6
Q
YAG CAP pre op drops
A
Alphagan, tropicamide
7
Q
Power for YAG CAP
A
1.3-1.8 mJ
8
Q
Off set for YAG CAP
A
+250
9
Q
Total shots for YAG CAP
A
10-40
10
Q
Post of drops for YAG CAP
A
Alphagan, PF
11
Q
LPI pre op drops
A
Alphagan, pilocarpine
12
Q
Power for LPI
A
3.0-6.0
13
Q
Off set for LPI
A
None
14
Q
Total shots of LPI
A
1-15
15
Q
Post op drops for LPI
A
Alphagan, PF
16
Q
Spacing of SLT
A
Space 1-2 HeNe beams apart
17
Q
YA CAP direction
A
Start from top to bottom, then side to side, it will open to a diamond
18
Q
best place to shoot for LPI
A
Into a crypt if possible at 11 or 1 o’clock. DO NOT SHOOT NEAR THE PUPIL-monocular diplopia