What would be the total force exerted on the gate of a 6 inch gate valve if the water pressure against it was 46 psi G
1300 pounds
Asbestos cement pipe installed below a 60 mm thick concrete floor must be at least how deep
600 mm
If concrete slab is less than 75 mills The ASBESTOS OR VIRTIFIED CLAY PIPING must be at least 600mm down from slab
When may a backwater valve be installed in a building drain
When it is normally open
What is the most likely reason for a well pump coming on as soon as the faucet is open?
A waterlogged pressure tank
A 4 inch cast-iron pipe with 1 inch insulation is the past through a wall how large diameter hole is required to be cut
6 1/2 inches
Remember to account for OD. Cast and others like (most) are measured in I.D and that would be a the reason of the your anwser would be 6”. But accounting a for the wall thickness
What must be installed along with any gear pumps
A pressure relief valve
A drainage pipe suspended from a ceiling inside a building is 7 1/2 inches from the ceiling to its centre at the most upstream end. What will be the measurement from the ceiling to the centre of the pipe if it travels 26 feet horizontally has a 8 foot horizontal offset using 2-45 elbows and then continues another 37 feet
26 inches
A branch with 34 fixing units discharges into a sewage sump what is the minimum size vent for the sump?
3 inches
A building’s roof measuring 90 m x 50 m would require how many flow control roof drains?
Five
A flat roof measures 20 m x 26 m and has a vertical wall on one side measuring 6 m x 20 m size the circular litre if the local rainfall intensity is 24 mm x 15 minutes
5 inch
What must accompany a lab sink that receives biohazardous waste?
A clean out above flood level rim
How’s the absorption rate of a step septic field determined?
By a percolation test
How is medical gas piping joined
By brazed joints
What is required on a circuit vented branch that has a horizontal offset using two- 45° elbows
An additional circuit vent
How much expansion will occur when a 15 m ABS pipe has a temperature change of 40°
60 mm ( SEE NOTES IN NPCB 2.3.3.11(2) )
Which backflow preventer below is not testable
A.PVBA
B.DCAP
C.RPBA
D.DCVA
B.DCAP
Properly cut thread on black iron pipe should allow how many hand turns of a fitting
3 1/2
What is the minimum distance between a well and a septic field?
30 m (SPM BC)
An air conditioner that discharges 0.05 L per second of condensation into a floor drain that would equate to how many fixture units
Two
( 0.05 l per second x 31.7 fu ) = 1.57 fu
Round up equals 2
Underground piping installed in a dug trench should be covered with appropriate backfill to what height
300 mm
Which of the following is not a hot water heating piping system
A.series loop
B. 2 pipe reverse return
C. 2 pipe direct return
D.one pipe gravity return
D.one pipe gravity return
Where is the ideal installation location for a circulator in a heating system
On the supply downstream of the expansion tank
When determining the location to install a condensing boiler, what must be considered?
Proximity to a floor drain
The discharge piping from a water service heaters T & P relief valve must be discharged within how many millimetres of a floor drain or suitable area
300 mm
Length is not considered when sizing one of these vents
A relief vent
B.stack vent
C.vent header
D.circuit vent
A.relief vent
Across fitting may not be installed in a DWV system except to connect what
Four vents
Which of the following may a half inch extracted tea formed from?
A. Three-quarter type M.
B. Half inch type K.
C. Half inch type L.
D. Three-quarter type K.
D. Three-quarter type K.
If four showerheads are installed along the wall, what would be the minimum measurement between the two outermost heads?
2.25 m
( minimum 750mm between adjacent heads) only THREE SPACING! Draw out do not multiply by 4 only the spaces BETWEEN THE 4 heads)
What is the minimum size vent for an oil interceptor?
1-1/4”
Code clause 2.5.5.2 sentance (a) shall not be less than 1-1/4”
What is a four wire zone valve wire to?
Thermostat, transformer, relay coil, control circuit
Which of the following fixtures may not be indirectly connected to a drainage system
A. a commercial dishwasher
B.a sterilizer
C.a drinking fountain
D.a water softener discharge
A commercial dishwasher
Clause 2.4.2.1
What are the minimum service connections for a mobile home?
4 inch sewer, and a three-quarter inch Water service
A pressure reducing valve must be installed if a service pressure is above what psi
80 psi
A twin tank water softener will house the brine in one tank and what in the other
Zeolite
Water that has dissolved mineral content of more than 181 mg/L would be called what
Hard water
150 -200mg/l = hard water
A private water cistern is fitted with a three-quarter, make up water pipe, installed by a municipal system. What size airgap would be required
Inch and a half gap
What does NPS stand for?
Pipe size
What is the maximum nominal horizontal offset permitted in a 3 inch soil or waste stack that is serving as a wet vent
2.5 m
Clause 2.5.2.1 sentance (i)
Which manufacturing method produces the strongest pipe
Extruded ( because it doesn’t have a weld, welds are always the weakest point)
What is the principle used in the operation of a water softener?
Ion exchange
If a flush tank urinal continuously flushes, what is faulty
The Siphon
Note : odd install- has a flush tank with a siphon feeding urinals. The flush tank volume determines how many urinals can be installed. The tank fills until it reaches the siphon, when the siphon is reached. Since the siphon is the was of flushing, if the urinals are continuously flushing the problem must be the siphon